Jae Mok ahn

Prof. Jae Mok ahn


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Healthcare Informatics Research
Verified
Journal Article
Open access
PDF file
JAJae Mok ahn
Jae Mok ahn
Ahn JM. Healthc Inform Res. 2017 Jan;23(1):53-59. https://doi.org/10.4258/hir.2017.23.1.53

1 January 2015 in Healthcare Informatics Research
Verified
Journal Article
Open access
PDF file
KHKyung Soon Hong
Kyung Soon Hong
KPKyu Tae Park
Kyu Tae Park
JAJae Mok ahn
Jae Mok ahn
Hong KS, et al. Healthc Inform Res. 2015 Jan;21(1):30-34. http://dx.doi.org/10.4258/hir.2015.21.1.30

1 January 2015 in Healthcare Informatics Research
Verified
Journal Article
Open access
PDF file
JAJae Mok ahn
Jae Mok ahn
Ahn JM. Healthc Inform Res. 2015 Apr;21(2):111-117. http://dx.doi.org/10.4258/hir.2015.21.2.111

22 May 2019
Verified
Book Chapter
Closed access
PDF file
JKJeom Keun Kim
Jeom Keun Kim
JAJae Mok ahn
Jae Mok ahn

20 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
NANagima Abdrasulova
Nagima Abdrasulova
MAMilana Aleksanyan
Milana Aleksanyan
MKMin Ju Kim
Min Ju Kim
JAJae Mok ahn
Jae Mok ahn
Photoplethysmography (PPG)-based heart rate variability (HRV) offers a cost-effective alternative to electrocardiography (ECG) for autonomic monitoring in wearable devices. We optimized signal processing on a 16-bit microcontroller by comparing 4th-order equivalent Butterworth and Elliptic IIR bandpass filters (0.8–20 Hz, zero-phase) at 1000, 500, and 250 Hz. Paired PPG–ECG recordings from 10 healthy adults were analyzed for ln HF, ln LF, and ln VLF using Lin’s concordance correlation coefficient (CCC), ±5% equivalence testing (TOST), and Passing–Bablok regression (PBR). Butterworth at 500 Hz preserved near-identity with ECG standard (CCC ≥0.94; TOST met equivalence; PBR slopes/intercepts: ln HF = 0.97x + 0.10, ln LF = 1.02x − 0.07, ln VLF = 1.01x − 0.03), while halving computational load. In contrast, Elliptic at 250 Hz degraded concordance (CCC ≈ 0.64) and failed equivalence, with greater bias from nonlinear phase and ripple-induced distortion. Elliptic performance improved at higher sampling but offered no benefit over Butterworth. These results support zero-phase Butterworth filtering at ≥500 Hz as the optimal balance of fidelity, robustness, and efficiency, enabling reliable PPG-HRV monitoring on low-power devices. As a pilot investigation (n = 10), this study establishes preliminary design parameters and optimal configurations to guide subsequent large-scale clinical validation.

4 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
NANagima Abdrasulova
Nagima Abdrasulova
MAMilana Aleksanyan
Milana Aleksanyan
MKMin Ju Kim
Min Ju Kim
JAJae Mok ahn
Jae Mok ahn
Photoplethysmography (PPG)-based heart rate variability (HRV) offers a cost-effective al-ternative to electrocardiography (ECG) for autonomic monitoring in wearable devices. We optimized signal processing on a 16-bit microcontroller by comparing 4th-order equiva-lent Butterworth and Elliptic IIR bandpass filters (0.8–20 Hz, zero-phase) at 1000, 500, and 250 Hz. Paired PPG–ECG recordings from 10 healthy adults were analyzed for ln HF, ln LF, and ln VLF using Lin’s concordance correlation coefficient (CCC), ±5% equivalence testing (TOST), and Passing–Bablok regression (PBR). Butterworth at 500 Hz preserved near-identity with ECG standard (CCC ≥ 0.94; TOST met equivalence; PBR slopes/intercepts: ln HF = 0.97x + 0.10, ln LF = 1.02x − 0.07, ln VLF = 1.01x − 0.03), while halving computational load. In contrast, Elliptic at 250 Hz degraded concordance (CCC ≈ 0.64) and failed equivalence, with greater bias from nonlinear phase and ripple-induced distortion. Elliptic performance improved at higher sampling but offered no benefit over Butterworth. These results support zero-phase Butterworth filtering at ≥500 Hz as the op-timal balance of fidelity, robustness, and efficiency, enabling reliable PPG-HRV monitor-ing on low-power devices. As a pilot investigation (n=10), this study establishes prelimi-nary design parameters and optimal configurations to guide subsequent large-scale clin-ical validation.