Federica Troisi

Dr. Federica Troisi

Cardiology Department, Ospedale Generale Regionale Francesco Miulli, Acquaviva delle Fonti, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
MGMassimo Grimaldi
Massimo Grimaldi
FQFederico Quadrini
Federico Quadrini
NCNicola Caporusso
Nicola Caporusso
FTFederica Troisi
Federica Troisi
NVNicola Vitulano
Nicola Vitulano
AMAntonio Di Monaco
Antonio Di Monaco
Background: Pulsed field ablation (PFA) is a novel, largely nonthermal ablative modality that, by virtue of its putative preferential action on myocardial tissue through the process of irreversible electroporation (IRE), may replace conventional thermal ablation for atrial fibrillation (AF). The recent inspIRE study confirmed safety and effectiveness of a fully integrated biphasic PFA system with a variable loop circular catheter for the treatment of paroxysmal AF. The majority of PFA procedures were performed using general anesthesia. However, due to the risks of general anesthesia we report the data regarding our sedation protocol used during inspIRE study. Methods: A total of 29 patients (mean age 55±9 years; 72% male) were enrolled as part of this analysis within the inspIRE trial. The sedation protocol is reported in the manuscript. The Richmond Agitation-Sedation Scale (RASS), the Visual Analogue Scale (VAS) and the Patient State Index were collected during sedation. Each patient was monitored using the Masimo Sedline. At the end of ablation, the Likert Scale Questionnaire (LSQ) was used to assess the patients' satisfaction with intraoperative analgesia-sedation. Results: No procedural complications were documented. Sufficient oxygen saturation was maintained in all patients during procedure. Non-invasive ventilation or tracheal intubation were not required for any patient. The RAAS score between -1 to -5 was obtained in 27 patients (93%) while the value 0 was obtained in 2 patients (7%). The VAS score between 0 to 2 was obtained in 24 patients (83%); the VAS score 3 in 3 patients (10%) and the VAS score 4 in 2 patients (7%). The PSI score <50 was achieved in 16 patients (55%) while the PSI between 50 and 70 was achieved in 9 patients (31%). Positive answers to LSQ were obtained in most patients. Conclusion: During PFA ablation procedures with the variable-loop circular catheter and its accompanying biphasic pulse, our deep sedation protocol is a valid alternative to general anesthesia.

Verified
Journal Article
Open access
PDF file
AMAntonio Di Monaco
Antonio Di Monaco
NVNicola Vitulano
Nicola Vitulano
FTFederica Troisi
Federica Troisi
FQFederico Quadrini
Federico Quadrini
IRImma Romanazzi
Imma Romanazzi
MGMassimo Grimaldi
Massimo Grimaldi
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and catheter ablation, which can be used in symptomatic patients refractory to antiarrhythmic therapy. Pulmonary vein isolation (PVI) remains the cornerstone of any ablation procedure. A major limitation of current catheter ablation procedures is important to recognize because even when the PVI is performed in highly experienced centers, PVI reconnection was documented in about 20% of patients. Therefore, better technology is needed to improve ablation lesions. One of the novelties in recent years is pulsed filed ablation (PFA), a non-thermal energy that uses trains of high-voltage, very-short-duration pulses to kill the cells. The mechanism of action of this energy consists of creating pores in the myocardiocyte cell membrane in a highly selective and tissue-specific way; this leads to death of the target cells reducing the risk of damage to surrounding non-cardiac tissues. In particular during the animal studies, PVI and atrial lines were performed effectively without PV stenosis. Using PFA directly on coronary arteries, there was no luminal narrowing, there has been no evidence of incidental phrenic nerve injury, and finally, PFA has been shown not to injure esophageal tissue when directly applied to the esophagus or indirectly through ablation in the left atrium. The aim of this review is to report all published animal and clinical studies regarding this new technology to treat paroxysmal and persistent AF.

28 April 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
FTFederica Troisi
Federica Troisi
PGPietro Guida
Pietro Guida
FQFederico Quadrini
Federico Quadrini
AMAntonio Di Monaco
Antonio Di Monaco
NVNicola Vitulano
Nicola Vitulano
MGMassimo Grimaldi
Massimo Grimaldi
Background: Awareness of radiation exposure risks associated to interventional cardiology procedures is growing. The availability of new technologies in electrophysiology laboratories has reduced fluoroscopy usage during arrhythmias ablations. The aim of this study was to describe procedures with and without X-Rays and to assess feasibility, safety, and short-term efficacy of zero fluoroscopy intervention in a high-volume center oriented to keep exposure to ionizing radiation as low as reasonably achievable. Methods: Cardiac catheter ablations performed in our hospital since January 2017 to June 2021. Results: A total of 1,853 procedures were performed with 1,957 arrhythmias treated. Rate of fluoroless procedures was 15.4% (285 interventions) with an increasing trend from 8.5% in 2017 to 22.9% of first semester 2021. The most frequent arrhythmia treated was atrial fibrillation (646; 3.6% fluoroless) followed by atrioventricular nodal reentrant tachycardia (644; 16.9% fluoroless), atrial flutter (215; 8.8% fluoroless), ventricular tachycardia (178; 17.4% fluoroless), premature ventricular contraction (162; 48.1% fluoroless), and accessory pathways (112; 31.3% fluoroless). Although characteristics of patients and operative details were heterogeneous among treated arrhythmias, use of fluoroscopy did not influence procedure duration. Moreover, feasibility and efficacy were 100% in fluoroless ablations while the rate of major complications was very low and no different with or without fluoroscopy (0.45 vs. 0.35%). Conclusion: Limiting the use of X-Rays is necessary, especially when the available technologies allow a zero-use approach. A lower radiation exposure may be reached, reducing fluoroscopy usage whenever possible during cardiac ablation procedures with high safety, full feasibility, and efficacy.

1 July 2008 in Journal of Cardiovascular Medicine
Verified
Journal Article
Closed access
FTFederica Troisi
Federica Troisi
SGStefania Greco
Stefania Greco
NBNatale Daniele Brunetti
Natale Daniele Brunetti
MBMatteo Di Biase
Matteo Di Biase
Background Right ventricle (RV) impairment could influence brain natriuretic peptide (BNP) circulating levels. It is not well known whether echocardiographic parameters assessing RV function could be related to BNP levels in patients with chronic heart failure (CHF). Controversial data are available about the role played by RV dysfunction in determining exercise capacity in CHF patients. Methods Sixty patients with CHF referred to our CHF Unit underwent blood sampling for BNP levels determination, cardiopulmonary exercise test with VO2 peak, VO2-AT and VE/VCO2 slope assessment and M-mode, two-dimensional and Doppler echocardiography with evaluation of right heart function [right atrial pressure (RAP), pulmonary artery pressure (PAP), severity of tricuspid regurgitation (TR), and tricuspid annular plane systolic excursion (TAPSE)]. Results A significant correlation was detectable between BNP levels and TAPSE (r = −0.33; P < 0.05), RAP (r = 0.34; P < 0.05), PAP (r = 0.42; P < 0.05), TR (P for trend 0.05); correlation with TAPSE remained significant even in multivariate. VO2 peak was significantly related to RAP (r = −0.38, P < 0.05) and TR (P for trend 0.05); AT with PAP (r = −0.40, P < 0.05), RAP (r = −0.50, P < 0.05), TR (P for trend 0.05). Moreover, patients with TAPSE greater than 16 mm had higher values of VO2 peak (13.68 ± 3.28 vs. 11.49 ± 2.37 ml/kg/m′, P < 0.05) and of VO2-AT (18.36 ± 1.60 vs. 10.23 ± 2.31 ml/kg/m′; P < 0.05). Conclusion Right heart dysfunction assessed by simple echocardiographic parameters is related to neurohormonal activation featured by increased BNP levels and to a worse functional capacity in CHF patients.

21 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AMAntonio Di Monaco
Antonio Di Monaco
FGFabiana Gregucci
Fabiana Gregucci
IBIlaria Bonaparte
Ilaria Bonaparte
IRImma Romanazzi
Imma Romanazzi
FTFederica Troisi
Federica Troisi
MGMassimo Grimaldi
Massimo Grimaldi
Stereotactic arrhythmia radioablation (STAR) is a novel therapeutic approach for cardiac arrhythmias. The aim of this trial is to investigate the feasibility of STAR for the treatment of paroxysmal atrial fibrillation (AF) in elderly patients. Inclusion criteria were age >70 years, symptomatic AF, antiarrhythmic drugs failure, or intolerance. All patients underwent to 4D cardiac computed tomography simulation. The clinical target volume was identified in the area around pulmonary veins (PV). Stereotactic arrhythmia radioablation was performed with a total dose of 25 Gy (single fraction) delivered in 3 min. Twenty patients were enrolled and 18 underwent STAR. One patient withdrew informed consent before treatment and one patient was excluded due to unfavourable oesophagus position. With a median follow-up (FU) of 16 months (range 12–23), no acute toxicity more than Grade 3 was reported. Five patients had a Grade 1 oesophagitis 24 h after STAR; eight patients had an asymptomatic Grade 1 pericardial effusion, and one patient had a torsade de pointes treated effectively by electrical cardioversion and subsequent cardiac implantable cardioverter-defibrillator implantation. Most patients had a significant reduction in AF episodes. Five patients, due to arrhythmias recurrences after STAR, performed electrophysiological study documenting successful PV isolation. Finally, a significant improvement of quality of life was documented (48 ± 15 at enrolment vs. 75 ± 15 at 12 months FU; P < 0.001). The present phase II trial demonstrated the feasibility of STAR in paroxysmal AF elderly patients and its potential role in increasing the quality of life. Surely, more robust data are needed about safety and efficacy. ClinicalTrials.gov: NCT04575662

7 March 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
LSLuca Sgarra
Luca Sgarra
Vanessa DesantisVanessa Desantis
Vanessa Desantis
AMAndrea Matteucci
Andrea Matteucci
VCVincenzo Paolo Caccavo
Vincenzo Paolo Caccavo
FTFederica Troisi
Federica Troisi
MGMassimo Grimaldi
Massimo Grimaldi
At its earliest appearance, atrial fibrillation (AF) is often unnoticed, asymptomatic, and/or merely device-detected. Widespread use of heart-rate monitoring technologies has facilitated such “nascent atrial fibrillation (nAF)” recognition. Consequently, clinicians face a growing number of patients affected by new-onset AF in the absence of a definite indication for anticoagulation due to several counterarguments: (1) a CHA2DS2-VA score ≤ 1 in otherwise apparently healthy subjects; (2) an uncertain embolic/hemorrhagic benefit/risk ratio with anticoagulation; (3) EKG demonstration and confirmation of AF; and (4) existence of a pathogenic mechanism other than atrial hypercoagulability. In this frustrating limitation of pharmacological options, cardiologists may miss a complete comprehension of drugs with proven anti-ictal potential, whose administration may serve both as a bridge strategy toward future anticoagulation and as a consolidative strategy paralleling anticoagulation. This review aims to summarize and elucidate such therapeutic strategies and their preventative mechanisms.