Nan Meng

Dr. Nan Meng

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
NMNan Meng
Nan Meng
XWXuejia Wang
Xuejia Wang
JSJing Sun
Jing Sun
DHDongming Han
Dongming Han
YBYan Bai
Yan Bai
MWMeiyun Wang
Meiyun Wang

18 May 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
NMNan Meng
Nan Meng
XWXuejia Wang
Xuejia Wang
JSJing Sun
Jing Sun
DHDongming Han
Dongming Han
XMXiaoyue Ma
Xiaoyue Ma
MWMeiyun Wang
Meiyun Wang

14 February 2019 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
WYWei Yue
Wei Yue
NMNan Meng
Nan Meng
JWJing Wang
Jing Wang
WLWenling Liu
Wenling Liu
YLYuxia Li
Yuxia Li
JCJingliang Cheng
Jingliang Cheng
This study evaluated and compared the performances of diffusion kurtosis imaging (DKI) and diffusion-weighted imaging (DWI) for diagnosing and histologically grading endometrial cancer. In this retrospective study, DKI and DWI data for 61 patients with endometrial cancer and 30 patients with a normal endometrium were analyzed, and the mean kurtosis (MK), mean diffusion coefficient (MD) and apparent diffusion coefficient (ADC) values for the endometrial cancer tissue and normal endometrial tissue were acquired. The parameters for the normal endometrium group (G0) and the endometrial cancer groups (G1, G2 and G3) were compared and analyzed. The receiver operating characteristic (ROC) curve was used to evaluate each parameter’s diagnostic accuracy and threshold. Spearman correlation analysis was used to analyze the correlations between all parameters and histological grades. The MK values for the G0, G1, G2 and G3 groups increased gradually, while the MD and ADC values decreased gradually. Except for the differences in the ADC values between G0 and G1, the differences among the groups were statistically significant (P < 0.05). The MK values had the highest diagnostic accuracy in differentiating G0 and (G1 + G2 + G3), G0 and G1, G1 and G2, and G2 and G3 (AUC = 0.93, 0.76, 0.91, 0.91, P < 0.05). MK was maximally correlated with histological grade, followed by MD and ADC (MK > MD > ADC; r = − 0.85, + 0.82, + 0.76, P < 0.01). Both DKI and DWI can be used to evaluate the diagnosis and histological grading of endometrial cancer. Compared with DWI, the DKI model is a more complete mathematical model with more sensitive parameters, which can more effectively evaluate the pathological and physiological characteristics of endometrial cancer.

5 May 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
NMNan Meng
Nan Meng
XWXue‐Jia Wang
Xue‐Jia Wang
JSJing Sun
Jing Sun
LHLing Huang
Ling Huang
ZWZhe Wang
Zhe Wang
MWMeiyun Wang
Meiyun Wang

1 November 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
TFTing Fang
Ting Fang
NMNan Meng
Nan Meng
PFPengyang Feng
Pengyang Feng
ZHZhun Huang
Zhun Huang
ZLZiqiang Li
Ziqiang Li
MWMeiyun Wang
Meiyun Wang

8 March 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
NMNan Meng
Nan Meng
FFFangfang Fu
Fangfang Fu
PFPengyang Feng
Pengyang Feng
ZLZiqiang Li
Ziqiang Li
HGHaiyan Gao
Haiyan Gao
MWMeiyun Wang
Meiyun Wang