The ventilation mode affects the cooling efficiency of the air conditioners significantly in marine data centers. Three different ventilation modes, namely, underfloor ventilation, overhead ventilation, side ventilation, are numerically investigated for a typical marine data center. Four independent parameters, including temperature, velocity, air age, and uniformity index, are applied to evaluate the performances of the three ventilation modes. Further, the analytic hierarchy process (AHP) entropy weight model is established and further analysis is conducted to find the optimal ventilation mode of the marine data center. The results indicate that the underfloor ventilation mode has the best performance in the airflow patterns and temperature distribution evaluation projects, with the highest scores of 91.84 and 90.60. If low energy consumption is required, it is recommended to select the overhead ventilation mode with a maximum score of 93.50. The current evaluation results agree fairly well with the three dimensional simulation results, which further proves that the AHP entropy weight method is reasonable and has a high adaptability for the evaluation of air conditioning ventilation modes.
The environment inside subway carriages is relatively enclosed, putting passengers at risk of respiratory infections during viral pandemics such as COVID-19 and SARS. This paper uses the Euler–Lagrange method to simulate the distribution of droplet nuclei produced by coughing under six different operating conditions in a subway carriage. The study investigates the impact of different air supply characteristics and ventilation methods, including mixed ventilation (MV), floor-supply, and ceiling-return ventilation (SFRC), on the distribution of droplets. These results indicate that under MV mode, the dispersion range of droplets during a patient’s cough is the largest, with an average droplet suspension rate (SR) of up to 77% at the initial moment. The SFRC system markedly diminishes droplet dispersion, decreasing the SR by 35%. Upon increasing the air supply velocity to 0.8 m/s, the SR diminishes to 6%, the probability of particles attaining a 2 m social distance (PRP) declines by roughly 70%, and the weighted average contamination range (CR) of coughing particles reaching a safe social distance reduces by 33.5%. These results may act as a guide for the subsequent design and optimization of airflow patterns in carriages to reduce the risk of cross-infection.
The COVID-19 pandemic presented substantial challenges to the healthcare systems in treating infected patients. The isolation ward is a crucial component in controlling the spread of respiratory diseases. A two-bed isolation ward is served as the subject of research, and the numerical simulation is used to analyze the indoor airflow distribution based on 12 cases with three ventilation modes and four patient relative postures. Three ventilation modes encompass stratum ventilation (SV), displacement ventilation (DV), and downward ventilation (DWV). Four patient relative postures involve supine (Sp-Sp), sitting (St-St), and side-lying in the same direction (Ly-Ly1) or back-to-back (Ly-Ly2). The results show that regarding the temperature distribution, and velocity distribution, air age distribution, DWV performs better than other ventilation modes. While regarding the contaminant concentration distribution, DV can better reduce the risk of cross-infection for patients and healthcare worker. This work can contribute valuable insights for the systematic design of wards in response to the emergent respiratory infectious diseases. It has significant practical implications for controlling the risk of cross-infection of respiratory diseases among personnel.
This study zeroes in on a standard double bed ship isolation ward, employing Computational Fluid Dynamics (CFD) to probe airflow arrangements. It scrutinizes three ventilation tactics while altering the contaminant mass flow rate from human exhalation, assessing comfort and cross-infection risks to pinpoint the best ventilation setup. The findings reveal displacement ventilation’s prowess in eliminating contaminants, thwarting cross-infections effectively. The diameter of contaminants exhaled by patients barely affects comfort but impacts indoor contaminant concentrations. This research is pivotal for curbing cross-infections in shipboard wards and offers crucial insights for isolation ward ventilation design on ships during respiratory droplet-borne viral disease outbreaks. It underscores the significance of proper ventilation in mitigating airborne virus transmission, providing a detailed analysis of airflow and contaminant dispersion via CFD. The results suggest displacement ventilation is an apt choice for shipboard isolation wards, offering energy efficiency and low noise. This study aids in devising effective infection control measures in healthcare settings, enhancing safety and comfort in shipboard isolation wards.