The potential applicability of a developed recycled textile material, based on acrylic spinning waste, as thermal insulation is conducted. The prepared acrylic spinning waste (AS) is thermo-physically characterized in terms of density, air permeability, and thermal conductivity. The results show that the density and air permeability are 10.583 kg/m3 and 1100 L/m2/s, respectively. In addition, the thermal conductivity is found to be 38.27 mW/(m K). The developed thermal insulator is then tested in a thermally controlled reduced scale cavity. Two walls of the cavity are outfitted with AS at two different locations and compared to the walls without AS. The comparison is made based on the wall surface temperature and heat flux. A reduction in surface temperature is observed in the walls outfitted with AS, compared to wall without AS. Indeed, compared to a control wall, the peak heat fluxes are reduced by 27.23% and 18.67%, respectively, related to the walls with AS at location 1 and location 2. The obtained results show that the AS is a competitive thermal insulation material and can increase the thermal performance of the building walls.
25 July 2017 in Journal of Thermal Science and Engineering Applications
In order to really assess the thermal performance of a wall incorporating phase change material (PCM), a reduced scale cavity has been monitored during two heating cycles. For each cycle, the heat source inside the test cell is switched “on” for 5 h and its setpoint is 38 °C and then switched off for 4 h. The outdoor air temperature is kept constant at a low temperature of 20 °C. Two walls are equipped with a PCM layer at different depths in order to study the optimal PCM location. The two other walls are wooden and glass to model a real building. The comparison between the four walls is made based on the absorbed heat fluxes and outside surface temperatures. The results show that the location of the PCM close to the heat source reaches its melting temperature and then reduces the surface temperature. At this location, the PCM layer stores the major part of the inlet heat flux. It takes 10 h to release the absorbed heat flux. However, the PCM layer, practically, does not have an effect on the surface temperatures and absorbed heat fluxes, when it is placed far from the heat source.
This paper highlights the impact of environmental conditions on cob buildings. Different factors such as wall thickness, material permeability and interactions between moisture and heat fluxes can all have significant effects on the performance and durability of cob buildings. An experimental and modeling-based study was conducted on the hygrothermal characterization of cob building materials, which were obtained by mixing earth and fibers. Two types of cob materials that can be used as insulation and to form structural materials in buildings were tested. The effect of outside temperature on adsorption isotherms was investigated for both materials. The experimental data were fitted using the GAB model, after which a new correlation of water content correlation was proposed. Three specific configurations were investigated in which cob material was subjected to moisture transfer and a zero, positive or negative temperature gradient. Based on the resulting measurements, a high coupling effect between heat and moisture transfer inside the structural material was analyzed. A comparison of the experimental and modeling results demonstrated the satisfactory correlation and reliability of the developed model. Simulations were carried out for various wall thicknesses, in order to assess the effect of heat and moisture transfer on water content. The three scenarios were simulated and distributions of water content inside the walls were determined. The results show that the wall thickness of cob buildings and the direction of heat and moisture fluxes affect water content distribution in the structure. A greater thickness of the cob wall leads to higher water content, but this relationship reverses when the heat and moisture fluxes move in the same direction.
Medium- and large-scale heat sinks are critical for thermal load management in high-performance systems. However, their high heat flux densities and limited space complicate cooling, leading to risks of overheating, performance degradation, or failure. This study employs the Cascaded Lattice Boltzmann Method (CLBM) to enhance their thermal performance. This numerical approach is known for being stable, accurate when dealing with complex boundaries, and efficient when computing in parallel. The numerical code was validated against a benchmark configuration and an experimental setup to ensure its reliability and accuracy. While previous studies have explored mixed convection in cavities or heat sinks, few have addressed configurations involving side air injection and boundary conditions periodicity in the transition-to-turbulent regime. This gap limits the understanding of realistic cooling strategies for compact systems. Focusing on mixed convection in the transition-to-turbulent regime, where buoyancy and forced convection interact, the study investigates the impact of Rayleigh number values ( to ) and Reynolds number values ( to ) on heat transfer. Simulations were conducted in a rectangular cavity with periodic boundary conditions on the vertical walls. Two heat sources are located on the bottom wall ( = 50 °C). Two openings, one on each side of the two hot sources, force a jet of fresh air in from below. An opening at the level of the cavity ceiling’s axis of symmetry evacuates the hot air. Mixed convection drives the flow, exhibiting complex multicellular structures influenced by the control parameters. Calculating the average Nusselt number (Nu) across the surfaces of the heat sink reveals significant dependencies on the Reynolds number. The proposed correlation between Nu and Re, developed specifically for this configuration, fills the current gap and provides valuable insights for optimizing heat transfer efficiency in engineering applications.
13 March 2018 in Journal of Solar Energy Engineering
Phase change materials (PCMs) used in the building walls constitute an attractive way to reduce the energy consumption and to increase the occupant's thermal comfort. However, there are some challenges to be faced among which the critical one is the PCM layer location allowing the greater heat flux reduction. In this work, the potential of PCM wallboards is evaluated experimentally using a heated reduced scale cavity including walls with or without PCM in a laboratory conditions. The cavity at reduced scale provides the flexibility to test most kinds of wall constructions in real time and allows faster installation and dismantling of the test walls. Three different PCM layer locations inside the walls are examined in terms of heat flux reduction and outside surface temperatures. The results confirm that the PCM layer reduces the peak heat flux compared to a reference wall (wall without PCM). Indeed, the PCM layer hugely affects the peak heat flux when it is placed on the inner face of the walls, near to the heat source. At this location, the peak heat flux reduction, compared to the reference wall, is 32.9%. Furthermore, for numerical validation purpose, the outside overall heat coefficient of the cavity outside walls is determined based on the experimental data.