Victor Perez-Padilla

Mr. Victor Perez-Padilla

Federal Institute For Materials Research and Testing, Berlin, Germany
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2021 in Advanced Materials Interfaces
Verified
Journal Article
Open access
PDF file
CAClara Anduix‐Canto
Clara Anduix‐Canto
DPDaniel Peral
Daniel Peral
Victor Perez-PadillaVictor Perez-Padilla
Victor Perez-Padilla
ADAnna Maria Diaz‐Rovira
Anna Maria Diaz‐Rovira
ALAlejandro Belmez Lledó
Alejandro Belmez Lledó
KCKang Wei Chou
Kang Wei Chou
The design of new electrically debondable adhesives has been an area of enormous interest for the recycling, repair, and reuse of electrical components for the last decade. However, the complexity of analyzing the debonding process under real conditions is a major obstacle for elucidating the mechanism. Here, a general mechanism for the electrical debonding of ionic acrylic adhesives based on imidazolium ionic liquids is reported. Using synchrotron‐based characterization techniques, in situ experiments mimicking real debonding conditions allowed for the first time the recording of ionic diffusion and chemical reactions during the debonding process. Diffusion of ionic species toward the electrodes triggers the debonding via electrochemical reactions at the adhesive–substrate interfaces. The selection of ionic adhesive chemistry and electrodelamination conditions will eventually determine the type of adhesive failure. A detailed understanding of the mechanism allows the development of new electrically debondable adhesives, which is crucial to promote circular economy and a more sustainable environment.

3 March 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
MKMartha Kimani
Martha Kimani
Victor Perez-PadillaVictor Perez-Padilla
Victor Perez-Padilla
VVVirginia Valderrey
Virginia Valderrey
KGKornelia Gawlitza
Kornelia Gawlitza
KRKnut Rurack
Knut Rurack
The development of methodologies to sense glyphosate has gained momentum due to its toxicological and ecotoxicological effects. In this work, a red-emitting and polymerizable guanidinium benzoxadiazole probe was developed for the fluorescence detection of glyphosate. The interaction of the fluorescent probe and the tetrabutylammonium salt of glyphosate was studied via UV/vis absorption and fluorescence spectroscopy in chloroform and acetonitrile. The selective recognition of glyphosate was achieved by preparing molecularly imprinted polymers, able to discriminate against other common herbicides such as 2,4-dichlorophenoxyacetic acid (2,4-D) and 3,6-dichloro-2-methoxybenzoic acid (dicamba), as thin layers on submicron silica particles. The limits of detection of 4.8 µM and 0.6 µM were obtained for the sensing of glyphosate in chloroform and acetonitrile, respectively. The reported system shows promise for future application in the sensing of glyphosate through further optimization of the dye and the implementation of a biphasic assay with water/organic solvent mixtures for sensing in aqueous environmental samples.

2 December 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
YSYijuan Sun
Yijuan Sun
Victor Perez-PadillaVictor Perez-Padilla
Victor Perez-Padilla
VVVirginia Valderrey
Virginia Valderrey
JBJérémy Bell
Jérémy Bell
KGKornelia Gawlitza
Kornelia Gawlitza
KRKnut Rurack
Knut Rurack
The widespread contamination of soil and water with perfluoroalkyl substances (PFAS) has caused considerable societal and scientific concern. Legislative measures and an increased need for remediation require effective on-site analytical methods for PFAS management. Here we report on the development of a green-fluorescent guanidine-BODIPY indicator monomer incorporated into a molecularly imprinted polymer (MIP) for the selective detection of perfluorooctanoic acid (PFOA). Complexation of PFOA by the indicator, which is mediated by concerted protonation-induced ion pairing-assisted hydrogen bonding, significantly enhances fluorescence in polar organic solvents. The MIP forms as a thin layer on silica nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, which provides an orange emission signal as internal reference, resulting in low measurement uncertainties. Using a liquid-liquid extraction protocol, this assay enables the direct detection of PFOA in environmental water samples and achieves a detection limit of 0.11 µM. Integration into an opto-microfluidic system enables a compact and user-friendly system for detecting PFOA in less than 15 minutes.

19 February 2025 in ACS Applied Polymer Materials
Verified
Journal Article
Open access
OJOliver D. Jamieson
Oliver D. Jamieson
JBJérémy Bell
Jérémy Bell
AHAlexander Hudson
Alexander Hudson
JSJoshua Saczek
Joshua Saczek
Victor Perez-PadillaVictor Perez-Padilla
Victor Perez-Padilla
MPMarloes Peeters
Marloes Peeters
An innovative polymer-based dual detection microfluidic platform has been developed for the accurate and reliable sensing of trace amounts of antibiotic tetracycline in environmental and food samples. This was achieved through the production of a bespoke polymeric material formed via an imprinting technique using a fluorescent dye. Thus, this enables dual detection of tetracycline, both thermally, via analyzing the heat-transfer resistance at the solid-liquid interface, and optically, through the inner filter effect. The combination of these two methods achieved a nanomolar limit of detection for tetracycline while also providing rapid, selective, and cost-effective sensing. Additionally, this method successfully detected tetracycline levels of 0.56 μM in blank egg samples which was significantly lower than the maximum residual level of 400 μg L-1 (0.9 μM). Our work shows that this approach can be used for the efficient detection of trace antibiotics in complex environmental and food samples, offering enhanced reliability through the integration of two complementary analysis techniques. This sensor has the potential to identify sources of antimicrobial resistance, which is crucial for targeted efforts to combat this pressing global health challenge.

24 March 2026 in Advanced Sensor Research
Verified
Journal Article
Open access
PDF file
Victor Perez-PadillaVictor Perez-Padilla
Victor Perez-Padilla
SBSamual C. Burnage
Samual C. Burnage
PWPhilipp Wittwer
Philipp Wittwer
VVVirginia Valderrey
Virginia Valderrey
JBJérémy Bell
Jérémy Bell
KRKnut Rurack
Knut Rurack
Perfluoroalkylic acids (PFAAs), a subclass of per‐ and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet‐based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation‐mediated hydrogen bond‐assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid‐liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µ m , with a dynamic range up to 200 µ m for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses.