GUGLIELMO MANENTI

Prof. Dr. GUGLIELMO MANENTI

Department of Biomedicine and Prevention, Faculty of Medicine and Surgery, University of Rome Tor Vergata, 00133 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2004 in British Journal of Radiology
Verified
Journal Article
Open access
MCM Cova
M Cova
ESE Squillaci
E Squillaci
FSF Stacul
F Stacul
GUGLIELMO MANENTIGUGLIELMO MANENTI
GUGLIELMO MANENTI
SGS Gava
S Gava
RPR Pozzi-Mucelli
R Pozzi-Mucelli
The purpose of this study was to evaluate the capability and the reliability of diffusion-weighted MRI in the evaluation of normal kidney and different renal lesions. 39 patients (10 normal volunteers and 29 patients with known renal lesions) underwent MRI of the kidneys by using a 1.5 T superconducting magnet. Axial fat suppressed turbo spin echo (TSE) T(2) and coronal fast field echo (FFE) T(1) or TSE T(1) weighted images were acquired for each patient. Diffusion-weighted (DW) images were obtained in the axial plane during breath-hold (17 s) with a spin-echo echo planar imaging (SE EPI) single shot sequence (repetition time (TR)=2883 ms, echo time (TE)=61 ms, flip angle=90 degrees ), with b value of 500 s mm(-2). 16 slices were produced with slice thickness of 7 mm and interslice gap of 1 mm. An apparent diffusion coefficient (ADC) map was obtained at each slice position. The ADC was measured in an approximately 1 cm region of interest (ROI) within the normal renal parenchyma, the detected renal lesions and the collecting system if dilated. ADC values in normal renal parenchyma ranged from 1.72 x 10(-3) mm(2) s(-1) to 2.65 x 10(-3) mm(2) s(-1), while ADC values in simple cysts (n=13) were higher (2.87 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1)). In hydronephrotic kidneys (n=6) the ADC values of renal pelvis ranged from 3.39 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1). In cases of pyonephrosis (n=3) ADC values of the renal pelvis were found to be lower than those of renal pelvis of hydronephrotic kidneys (0.77 x 10(-3) mm(2) s(-1) to 1.07 x 10(-3) mm(2) s(-1)). Solid benign and malignant renal tumours (n=7) showed ADC values ranging between 1.28 x 10(-3) mm(2) s(-1) and 1.83 x 10(-3) mm(2) s(-1). In conclusion diffusion-weighted MR imaging of the kidney seems to be a reliable way to differentiate normal renal parenchyma and different renal diseases. Clinical experience with this method is still preliminary and further studies are required.

1 December 2001 in Radiology
Verified
Journal Article
Open access
CPClaudio M. Pacella
Claudio M. Pacella
GBGiancarlo Bizzarri
Giancarlo Bizzarri
FMFabrizio Magnolfi
Fabrizio Magnolfi
PCPiero Cecconi
Piero Cecconi
BCBruno Caspani
Bruno Caspani
ZRZaccaria Rossi
Zaccaria Rossi
To evaluate the safety, local effectiveness, and long-term results of laser thermal ablation (LTA) in the treatment of small hepatocellular carcinoma (HCC). Ninety-two biopsies proved small HCCs (range, 0.8-4.0 cm) in 74 patients who were treated percutaneously with LTA in an outpatient clinic. A laser at a power of 5.0 W was coupled with one to four fibers that were advanced through 21-gauge needle(s) for 6-12 minutes. All lesions were evaluated with computed tomography (CT) for changes in size and vascular pattern, recurrence rates, and cumulative survival rates. Patients were examined for complications. No major complications occurred in 117 LTA sessions, with an average of 1.3 sessions per tumor. At 3 months, CT scans showed a nonenhancing area (complete necrosis) in 89 (97%) of 92 lesions. During follow-up (range, 6-66 months; mean, 25.3 months), 84 tumors (91%) decreased in size. The local recurrence rates (range, 1-5 years) ranged from 1.6% to 6.0%. Recurrence rates (range, 12-60 months) in other liver segments ranged from 24% to 73%. Cancer-free survival rates (range, 1-4 years) ranged from 73% to 24%. Overall survival rates were 99%, 68%, and 15% at 1, 3, and 5 years, respectively. Twenty-one patients (28%) died. LTA is a safe and effective treatment for small HCC.

1 March 2008 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
GUGLIELMO MANENTIGUGLIELMO MANENTI
GUGLIELMO MANENTI
MRM. Di Roma
M. Di Roma
SMS. Mancino
S. Mancino
DBD. A. Bartolucci
D. A. Bartolucci
GPG. Palmieri
G. Palmieri
GSG. Simonetti
G. Simonetti

1 June 2007 in Investigative Radiology
Verified
Journal Article
Closed access
GUGLIELMO MANENTIGUGLIELMO MANENTI
GUGLIELMO MANENTI
MCMarco Carlani
Marco Carlani
SMStefano Mancino
Stefano Mancino
VCVittorio Colangelo
Vittorio Colangelo
MRMauro Di Roma
Mauro Di Roma
GSGiovanni Simonetti
Giovanni Simonetti
To explore the feasibility of 3T magnetic resonance (MR) diffusion tensor imaging (DTI) and fiber tracking (FT) in patients with prostate cancer. Thirty consecutive patients (mean age, 62.5 years) with biopsy proven prostate cancer underwent 3T-MR imaging (MRI) and DTI using a 6-channel external phased-array coil before radical prostatectomy. Regions of interest of 14 pixels were defined in tumors and nonaffected areas in the peripheral zone (PZ) and central gland (CG), according to histopatology after radical prostatectomy. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were determined. Differences in mean ADC and FA values among prostate cancer, normal PZ and CG were compared by 2-sided Student t test. The predominant diffusion direction of the prostate anisotropy was color coded on a directionally encoded color (DEC) map. A 3D reconstruction of fiber tract orientations of the whole prostate was determined using the continuous tracking method. The overall image quality for tumor localization and local staging was assessed in retrospective matching with whole-mount section histopathology images. Nodules detected at MRI were classified as matched lesions if tumor presence and extension were evidenced at histopathology. For all the patients, the DTI sequence images were suitable for the evaluation of the zonal anatomy of the prostate gland and the tumor localization. Quantitative evaluation of the regions of interest (ROIs) showed a mean ADC value significantly lower in the peripheral neoplastic area (1.06 +/- 0.37 x 10(-3) mm2/s) than in the normal peripheral portion (1.95 +/- 0.38 x 10(-3) mm2/s) (P < 0.05). The mean FA values calculated in the normal peripheral (0.47 +/- 0.04) and central area (0.41 +/- 0.08) were very similar (P > 0.05). The mean FA values in the neoplastic lesion (0.27 +/- 0.05) were significantly lower (P < 0.05) than in the normal peripheral area and in the normal central and adenomyomatous area. DEC map showed a top-bottom type preferential direction in the peripheral but not in the central area, with the tumor lesions reducing the diffusion coding direction represented as color zones tending toward gray. Tractographic analysis permitted good delineation of the prostate anatomy (capsule outline, peripheral and central area borders) and neoplastic lesion extension and capsule infiltration compared with histopathology. Three Tesla DTI of the prostate gland is feasible and has the potential for providing improved diagnostic information.

16 September 2012 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
UTUmberto Tarantino
Umberto Tarantino
EFEzio Fanucci
Ezio Fanucci
RIRiccardo Iundusi
Riccardo Iundusi
MCMonica Celi
Monica Celi
SASimone Altobelli
Simone Altobelli
GUGLIELMO MANENTIGUGLIELMO MANENTI
GUGLIELMO MANENTI
Background Patients with low back pain frequently demonstrate recumbent magnetic resonance imaging (MRI) alterations not always related to homogeneous clinical symptoms. The purpose of this study was to evaluate and quantify the statistical significance of variations of some anatomical parameters of the lumbosacral spine and reveal occult disc pathologies from recumbent to upright position in patients with acute and chronic low back pain. Materials and methods Fifty-seven patients complaining of low back pain (27 women, 30 men) underwent dynamic lumbosacral MRI with a 0.25-T tilting system (G-scan Esaote). We settled five parameters for which variations have been evaluated: lumbosacral angle, lordosis angle, L3–L4 intersomatic disc height, L3–L4 interspinous processes distance, and widest anteroposterior dural sac diameter. Images were obtained in both recumbent and upright positions. Results Statistically significant differences [one-way analysis of variance (ANOVA), p = 0.0043] were found between each pair of values of parameters sampled in recumbent and upright positions. In 70 % of patients, on visual qualitative analysis only, an increment of disc protrusions and/or spondylolisthesis was found in the upright position; in three cases, in the upright position only, an interarticular pseudocyst was found. Conclusions Dynamic MRI with an open-configuration, low-field tilting MRI system is a feasible and promising tool to study degenerative pathology of the spine. Moreover, in cases of low back pain with negative MRI in the recumbent position or in patients with pain in the upright position only, tilting MRI permits visualization of occult spine and disc pathologies in patients with acute or chronic low back pain.

17 June 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
GUGLIELMO MANENTIGUGLIELMO MANENTI
GUGLIELMO MANENTI
TPTommaso Perretta
Tommaso Perretta
EGEleonora Gaspari
Eleonora Gaspari
CPChiara A. Pistolese
Chiara A. Pistolese
LSLia Scarano
Lia Scarano
SMSalvatore Antonio Masala
Salvatore Antonio Masala