Ying Xi

Ms. Ying Xi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2023 in Journal of Mass Spectrometry
Verified
Journal Article
Open access
YXYing Xi
Ying Xi
Alexandria L. SohnAlexandria L. Sohn
Alexandria L. Sohn
AJAlena N. Joignant
Alena N. Joignant
SCStephanie M. Cologna
Stephanie M. Cologna
BPBoone Prentice
Boone Prentice
DMDavid Chalres Muddiman
David Chalres Muddiman
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra‐ and inter‐laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.

14 March 2023 in Journal of Mass Spectrometry
Verified
Journal Article
Open access
AJAlena N. Joignant
Alena N. Joignant
YXYing Xi
Ying Xi
DMDavid Chalres Muddiman
David Chalres Muddiman
Biospecimens with nearly flat surfaces on a flat stage are typically required for laser‐based mass spectrometry imaging (MSI) techniques. However, sampling stages are rarely perfectly level, and accounting for this and the need to accommodate non‐flat samples requires a deeper understanding of the laser beam depth of focus. In ablation‐based MSI methods, a laser is focused on top of the sample surface, ensuring that the sample is at the focal point or remains within depth of focus. In general, the depth of focus of a given laser is related to the beam quality (M2) and the wavelength (λ). However, because laser is applied on a biological sample, other variables can also impact the depth of focus, which could affect the robustness of the MSI techniques for diverse sample types. When the height of a sample ranges outside of the depth of focus, ablated area and the corresponding ion abundances may vary as well, increasing the variability of results. In this tutorial, we examine the parameters and equations that describe the depth of focus of a Gaussian laser beam. Additionally, we describe several approaches that account for surface roughness exceeding the depth of focus of the laser.

29 November 2021 in Metabolites
Verified
Journal Article
Open access
PDF file
YXYing Xi
Ying Xi
DMDavid Chalres Muddiman
David Chalres Muddiman
Mass spectrometry imaging is a powerful tool to analyze a large number of metabolites with their spatial coordinates collected throughout the sample. However, the significant differences in ionization efficiency pose a big challenge to metabolomic mass spectrometry imaging. To solve the challenge and obtain a complete data profile, researchers typically perform experiments in both positive and negative ionization modes, which is time-consuming. In this work, we evaluated the use of the dicationic reagent, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride (abbreviated to [C5(bpyr)2]F2) to detect a broad range of metabolites in the positive ionization mode by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI MSI). [C5(bpyr)2]F2 at 10 µM was doped in 50% MeOH/H2O (v/v) electrospray solvent to form +1 charged adducted ions with anionic species (−1 charged) through post-electrospray ionization. This method was demonstrated with sectioned rat liver and hen ovary. A total of 73 deprotonated metabolites from rat liver tissue sections were successfully adducted with [C5(bpyr)2]2+ and putatively identified in the adducted positive ionization polarity, along with 164 positively charged metabolite ions commonly seen in positive ionization mode, which resulted in 44% increased molecular coverage. In addition, we were able to generate images of hen ovary sections showing their morphological features. Following-up tandem mass spectrometry (MS/MS) indicated that this dicationic reagent [C5(bpyr)2]2+ could form ionic bonds with the headgroup of glycerophospholipid ions. The addition of the dicationic reagent [C5(bpyr)2]2+ in the electrospray solvent provides a rapid and effective way to enhance the detection of metabolites in positive ionization mode.

23 July 2025 in Dairy
Verified
Journal Article
Open access
PDF file
FPFabiellen Cristina Pereira
Fabiellen Cristina Pereira
SKSagara Nelum Kumara
Sagara Nelum Kumara
MAMuhammad Ahsin
Muhammad Ahsin
LALamis Ali
Lamis Ali
YXYing Xi
Ying Xi
PGPablo Gregorini
Pablo Gregorini
This on-farm study evaluated the effects of a regenerative (plant polyculture) as compared to conventional (monoculture) pasture-based New Zealand dairy production system on milk and yoghurt nutraceutical properties and environmental impact. Milk and yoghurt produced by two adjacent regenerative and conventional farms were sampled throughout the year and analyzed for chemical composition, metabolomics, and microbiome. Milk samples were also collected over four consecutive days (one day after herbage sampling) on four occasions throughout lactation: early lactation (October), peak lactation (December/January), mid-lactation (March), and late lactation (May). Overall, the regenerative system had a lower environmental impact while maintaining a similar yield and the same milk composition compared to conventional systems. Furthermore, milk and yoghurt from the regenerative system had a more favourable profile of phytochemical antioxidants with potential positive benefits to human health (anti-inflammatory and antioxidant).

22 September 2026 in Agriculture
Verified
Journal Article
Open access
PDF file
FPFabiellen Cristina Pereira
Fabiellen Cristina Pereira
SKSagara Nelum Kumara
Sagara Nelum Kumara
MAMuhammad Ahsin
Muhammad Ahsin
LALamis Ali
Lamis Ali
YXYing Xi
Ying Xi
PGPablo Gregorini
Pablo Gregorini
Societal expectations for dairy production increasingly demand reductions in environmental impacts alongside improvements in milk nutritional quality. Animal-based strategies have therefore been explored, including the phenotyping and selection of A1 Protein Free (A1PF) cows that excrete less milk urea nitrogen (MUN) and less urinary nitrogen (low-MUN cows). This study characterizes the milk metabolome of Low-MUN cows, examining metabolomic patterns associated with reduced nitrogen excretion and potential implications for milk quality. Three herd tests were conducted on a population of 1600 Holstein–Friesian cows to identify a sample of 200 individuals representing the extremes of MUN concentrations (the lowest 100 and highest 100). Milk samples were collected from these cows during mid and late lactation for MUN determination. From this group, metabolomic profiles of milk and urinary N concentrations were analyzed in 20 distinct individuals (the lowest 10 and highest 10 MUN concentrations). Overall, only modest differences in milk metabolomic composition were observed between Low-MUN and High-MUN cows; however, the differences did not remain significant after Benjamini–Hochberg correction for multiple comparisons (FDR < 0.05). Caffeic acid 3-sulfate, isovanillic acid sulfate, catechol sulfate and 3-indoxyl sulfate were more abundant in the high-MUN group, whereas n-acetyl-L-citrulline and guanosine monophosphate were significantly elevated in low-MUN cows. These metabolites are associated with antioxidant activity and nitrogen metabolism, suggesting subtle differences in metabolic function between groups. However, since the overall metabolomic profiles were largely similar, the presence of specific compounds linked to nitrogen-use efficiency and potential animal-based strategies targeting reduced nitrogen excretion may contribute to environmental sustainability without compromising milk metabolic quality. Nevertheless, further research is required to confirm these findings and establish more conclusive evidence regarding the metabolic and functional implications of the Low-MUN phenotype.