Carmel M. Moran

Prof. Carmel M. Moran

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2020 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
CMCarmel M. Moran
Carmel M. Moran
ATAdrian J. W. Thomson
Adrian J. W. Thomson
Ultrasound imaging is a well-established clinical imaging technique providing real-time, quantitative anatomical and physiological information in humans. The lack of ionizing radiation and relative low purchase and maintenance costs results in it being one of the most frequently used clinical imaging techniques with increasing use for guiding interventional clinical procedures. Until 20 years ago, translation of clinical ultrasound practices to preclinical applications proved a significant technological challenge due to the smaller size (25 g vs. 70 kg) and rapid conscious heart-rate (500–700 bpm vs. 60 bpm) of the mouse requiring an increase in both spatial and temporal resolution of 10–20-fold in order to achieve diagnostic information comparable to that achieved clinically. Since 2000 [1], these technological challenges have been overcome and commercial high frequency ultrasound scanners have enabled longitudinal studies of disease progression in small animal models to be undertaken. Adult, neonatal and embryonic rats, mice and zebrafish can now be scanned with resolutions down to 30 microns and with sufficient temporal resolution to enable cardiac abnormalities in all these species to be identified. In mice and rats, quantification of blood flow in cardiac chambers, renal, liver and uterine vessels, and intra-mural tissue movements can be obtained using the Doppler technique. Ultrasonic contrast microbubbles used routinely for clinical applications are now being further developed to include targeting mechanisms and drug-loading capabilities and the results in animal models bode well for translation for targeted drug delivery in humans.

1 March 2011 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
CMCarmel M. Moran
Carmel M. Moran
SPStephen D. Pye
Stephen D. Pye
WEWilliam Ellis
William Ellis
AJAnna Janeczko
Anna Janeczko
KMKeith D. Morris
Keith D. Morris
HFHamish M. Fraser
Hamish M. Fraser
Nine ultrasound transducers from six ultrasound scanners were assessed for their utility for preclinical ultrasound imaging. The transducers were: L8-16, L10-22 (Diasus; Dynamic Imaging Ltd., Livingston, UK); L17-5, L15-7io (iU22; Philips, Seattle, WA, USA), HFL38/13-6 (MicroMaxx; Sonosite Inc., Bothell, WA, USA); il3Lv (Vivid 5; GE, Fairfield, CT, USA), RMV 704 (Vevo 770; Visualsonics Inc., Toronto, Canada) and MS550S, MS550D (Vevo 2100; Visualsonics Inc.). A quantitative analysis of the ultrasound images from all nine transducers employed measurements of the resolution integral as an indication of the versatility and technology of the ultrasound scanners. Two other parameters derived from the resolution integral, the characteristic resolution and depth of field, were used to characterise imaging performance. Six of these transducers were also assessed qualitatively by ultrasonically scanning 59 female common marmosets (Callithrix jacchus) yielding a total of 215 scans. The quantitative measurements for each of the transducers were consistent with the results obtained in the qualitative in vivo assessment. Over a 0-10 mm imaging depth, the values of the resolution integral, characteristic resolution and depth of field, measured using the Edinburgh Pipe Phantom, ranged in magnitude from 7-72, 93-930 μm and 3.3-9.2 mm respectively. The largest resolution integrals were obtained using the Vevo 770 and Vevo 2100 scanners. The Edinburgh Pipe Phantom provides a quantitative method of characterising the imaging performance of preclinical imaging scanners.

20 February 2013 in Experimental Physiology
Verified
Journal Article
Closed access
PDF file
CMCarmel M. Moran
Carmel M. Moran
ATAdrian J. W. Thomson
Adrian J. W. Thomson
EREva Rog‐Zielinska
Eva Rog‐Zielinska
GGGillian A. Gray
Gillian A. Gray

1 June 2002 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
CMCarmel M. Moran
Carmel M. Moran
RWR.J Watson
R.J Watson
KFK.A.A Fox
K.A.A Fox
WMW.N McDicken
W.N McDicken

1 May 2000 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
CMCarmel M. Moran
Carmel M. Moran
TAT. Anderson
T. Anderson
SPS.D. Pye
S.D. Pye
VSV. Sboros
V. Sboros
WMW.N. McDicken
W.N. McDicken

2 October 2018 in Science Signaling
Verified
Journal Article
Closed access
PDF file
Javier Moral-SanzJavier Moral-Sanz
Javier Moral-Sanz
SLSophronia A. Lewis
Sophronia A. Lewis
SMSandy MacMillan
Sandy MacMillan
FRFiona A. Ross
Fiona A. Ross
ATAdrian Thomson
Adrian Thomson
MEMark Evans
Mark Evans
Hypoxic pulmonary vasoconstriction (HPV), which aids ventilation-perfusion matching in the lungs, is triggered by mechanisms intrinsic to pulmonary arterial smooth muscles. The unique sensitivity of these muscles to hypoxia is conferred by mitochondrial cytochrome c oxidase subunit 4 isoform 2, the inhibition of which has been proposed to trigger HPV through increased generation of mitochondrial reactive oxygen species. Contrary to this model, we have shown that the LKB1–AMPK-α1 signaling pathway is critical to HPV. Spectral Doppler ultrasound revealed that deletion of the AMPK-α1 catalytic subunit blocked HPV in mice during mild (8% O2) and severe (5% O2) hypoxia, whereas AMPK-α2 deletion attenuated HPV only during severe hypoxia. By contrast, neither of these genetic manipulations affected serotonin-induced reductions in pulmonary vascular flow. HPV was also attenuated by reduced expression of LKB1, a kinase that activates AMPK during energy stress, but not after deletion of CaMKK2, a kinase that activates AMPK in response to increases in cytoplasmic Ca2+. Fluorescence imaging of acutely isolated pulmonary arterial myocytes revealed that AMPK-α1 or AMPK-α2 deletion did not affect mitochondrial membrane potential during normoxia or hypoxia. However, deletion of AMPK-α1, but not of AMPK-α2, blocked hypoxia from inhibiting KV1.5, the classical “oxygen-sensing” K+ channel in pulmonary arterial myocytes. We conclude that LKB1–AMPK-α1 signaling pathways downstream of mitochondria are critical for the induction of HPV, in a manner also supported by AMPK-α2 during severe hypoxia.