Shih-Chun Chao

Shih-Chun Chao


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HCHung-Chih Chen
Hung-Chih Chen
MCMichael Chou
Michael Chou
MLMing-Tsung Lee
Ming-Tsung Lee
CLChia-Yi Lee
Chia-Yi Lee
CYChe-Ning Yang
Che-Ning Yang
SCShih-Chun Chao
Shih-Chun Chao
The purpose of this article is to investigate the diagnostic value of Pulsar perimetry (PP), optical coherence tomography (OCT), and optical coherence tomography angiography (OCTA) in pre-perimetric glaucoma (PPG) and perimetric glaucoma (PG). This retrospective cross-sectional study included 202 eyes (145 eyes in the control group, 40 eyes in the PPG group, and 17 eyes in the PG group) from 105 subjects. The results were analyzed by paired t-tests and Wilcoxon signed-rank test. The area under the curve (AUC), sensitivity, and specificity were used to evaluate the diagnostic accuracy. Pearson correlation was used to investigate the relationships of each parameter. The most sensitive parameters for differentiating the control group from the PPG group by using Pulsar, OCT, and OCTA were square loss variance of PP (AUC = 0.673, p < 0.001), superior ganglion cell complex thickness (AUC = 0.860, p < 0.001), and superior-hemi retina thickness (AUC = 0.817, p < 0.001). In the PG group, the most sensitive parameters were mean defect of PP (AUC = 0.885, p < 0.001), whole image of ganglion cell complex thickness (AUC = 0.847, p < 0.001), and perifoveal retina thickness (AUC = 0.833, p < 0.001). The mean defect of PP was significantly correlated with vascular parameters (radial peripapillary capillary (RPC), p = 0.008; vessel density of macular superficial vascular complex (VDms), p = 0.001; vessel density of macular deep vascular complex (VDmd), p = 0.002). In conclusion, structural measurements using OCT were more sensitive than vascular measurements of OCTA and functional measurements of PP for PPG, while PP was more sensitive than the structural and vascular measurements for PG. The mean defect of PP was also shown to be highly correlated with the reduction of vessel density.

30 April 2024 in In Vivo
Verified
Journal Article
Open access
PDF file
HCHung-Chih Chen
Hung-Chih Chen
PYPei-Yu Yang
Pei-Yu Yang
JCJung-Sheng Chen
Jung-Sheng Chen
DBDa-Tian Bau
Da-Tian Bau
SCShih-Chun Chao
Shih-Chun Chao
Background/Aim: Given the characteristics of Serratia marcescens (S. marcescens), this study aimed at investigating its presence in the hands and contact lens cases of orthokeratology wearers, along with the status of bacterial contamination. Patients and Methods: The 39 patients received the questionnaires about the background of orthokeratology and hygiene habits. A total of 39 contact lens cases and 39 hand samples from the patients were collected at Show Chwan Memorial Hospital from June to August in 2020 and sent to National Chung Cheng University for DNA extraction and PCR identification. Results: The results indicated a detection rate of 5.13% for S. marcescens in the contact lens cases and 12.82% in the hand samples. Additionally, 66.67% of contact lens case samples and 30.77% of hand samples found positive for 16s bacterial amplicons. The relationship between hand contamination and the duration of contact lens usage were revealed for both S. marcescens (p=0.021) and 16s bacterial amplicons (p=0.048). Conclusion: The results indicated that hand hygiene is more critical than focusing on contact lens hygiene when it comes to preventing S. marcescens infections. Nevertheless, both proper hand and contact lens hygiene practices can reduce the detection of bacterial eye pathogens, especially a common intestinal bacterium.

16 January 2024 in Taiwan Journal of Ophthalmology
Verified
Journal Article
Open access
YCYa-Feng Cheng
Ya-Feng Cheng
HLHung-Yu Lin
Hung-Yu Lin
SCShih-Chun Chao
Shih-Chun Chao
Incomplete involution of the anterior tunica vasculosa lentis is observed in most newborns, including persistent pupillary membrane (PPM) and accessory iris membrane (AIM). PPM is a common congenital ocular anomaly characterized by delicate iris strands along the pupil. AIM is a rare congenital ocular anomaly characterized by iris tissue strands arising from the iris collarette, forming a pseudopupil. Although most of these membranes do not lead to visual impairment, they can pose challenges during cataract surgery. Our case highlights a unique scenario involving the concurrent presence of PPM and AIM in cataract surgery. The surgeries were performed uneventfully without postoperative complications. To prevent unnecessary interventions and potential disappointment, it is essential to individually assess and plan strategies for patients with either PPM or AIM.