Xiaogang Wu

Dr. Xiaogang Wu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2017 in Journal of Polymer Research
Verified
Journal Article
Closed access
PDF file
YWYanqin Wang
Yanqin Wang
YXYa-Nan Xue
Ya-Nan Xue
SLShuang-Ran Li
Shuang-Ran Li
XZXue-Hui Zhang
Xue-Hui Zhang
HFHeng-Xiao Fei
Heng-Xiao Fei
WCWeiyi Chen
Weiyi Chen

28 December 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
XWXiaogang Wu
Xiaogang Wu
NWNingning Wang
Ningning Wang
ZWZhaowei Wang
Zhaowei Wang
WYWeilun Yu
Weilun Yu
YWYanqin Wang
Yanqin Wang
WCWeiyi Chen
Weiyi Chen
Mechanical load-induced intraosseous pressure gradients may result in some fluid stimuli effects, such as fluid flow and fluid shear stress (FSS), which may enable bone cells to detect external mechanical signals. Interstitial bone fluid flow is known to occur in lacunar–canalicular porosity (PLC). In order to characterize lacunar–canalicular fluid flow behavior, a hierarchical osteon system is developed. The osteon is modeled as a poroelastic annular cylinder with two types of impermeable boundary cases considered on its outer wall: one is elastic restrained (Case I), whereas the other is displacement confined (Case II). Analytical solutions such as canalicular fluid velocity, pressure, fluid flow rate (FFR), and shear stress are obtained. Results show that the amplitudes of FFR and FSS are proportional to strain amplitude and frequency. However, the key loading factor governing canalicular fluid flow behavior is the strain rate. The larger canalicular radius is, the larger amplitudes of FFR and FSS generalized, especially, the FSS amplitude is proportional to canalicular radius. In addition, both FFR and FSS amplitudes produced in case II are larger than those of case I. Strain rate can be acted as a representative loading parameter governing the canalicular fluid flow behavior under a physiological state. This model can facilitate better understanding the load induced the fluid permeation in the PLC. The approach can also be used to analyze the structure of the proteoglycan matrix in the fluid space surrounding the osteocytic process in the canaliculus.

11 July 2023 in Acta Mechanica Sinica
Verified
Journal Article
Closed access
PDF file
YYYang Yan
Yang Yan
JYJianhao Yu
Jianhao Yu
YWYan Wang
Yan Wang
HDHao Dong
Hao Dong
KZKai Zhang
Kai Zhang
WCWeiyi Chen
Weiyi Chen

15 January 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
XFXuanze Fan
Xuanze Fan
AZAohua Zhang
Aohua Zhang
QZQingli Zheng
Qingli Zheng
PLPengcui Li
Pengcui Li
YWYanqin Wang
Yanqin Wang
YWYonghong Wang
Yonghong Wang
The prevention, control and treatment of cerebral aneurysm (CA) has become a common concern of human society, and by simulating the biomechanical environment of CA using finite element analysis (FEA), the risk of aneurysm rupture can be predicted and evaluated. The target models of the current study are mainly idealized single-layer linear elastic cerebral aneurysm models, which do not take into account the effects of the vessel wall structure, material constitution, and structure of the real CA model on the mechanical parameters. This study proposes a reconstruction method for patient-specific trilaminar CA structural modeling. Using two-way fluid-structure interaction (FSI), we comparatively analyzed the effects of the differences between linear and hyperelastic materials and three-layer and single-layer membrane structures on various hemodynamic parameters of the CA model. It was found that the numerical effects of the different CA membrane structures and material constitution on the stresses and wall deformations were obvious, but does not affect the change in its distribution pattern and had little effect on the blood flow patterns. For the same material constitution, the stress of the three-layer membrane structure were more than 10.1% larger than that of the single-layer membrane structure. For the same membrane structure, the stress of the hyperelastic material were more than 5.4% larger than that of the linear elastic material, and the displacement of the hyperelastic material is smaller than that of the linear elastic material by about 20%. And the maximum value of stress occurred in the media, and the maximum displacement occurred in the intima. In addition, the upper region of the tumor is the maximum rupture risk region for CA, and the neck of the tumor and the bifurcation of the artery are also the sub-rupture risk regions to focus on. This study can provide data support for the selection of model materials for CA simulation and analysis, as well as a theoretical basis for clinical studies and subsequent research methods.

2 September 2022 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
YSYuqin Sun
Yuqin Sun
KZKai Zhang
Kai Zhang
HDHao Dong
Hao Dong
YWYan Wang
Yan Wang
YYYang Yan
Yang Yan
WCWeiyi Chen
Weiyi Chen

22 August 2024 in Acta Mechanica Sinica
Verified
Journal Article
Closed access
PDF file
AZAohua Zhang
Aohua Zhang
XFXuanze Fan
Xuanze Fan
ZYZhengbiao Yang
Zhengbiao Yang
YXYutang Xie
Yutang Xie
TWTao Wu
Tao Wu
WCWeiyi Chen
Weiyi Chen