This study aimed to determine the incidence and the prognosis of incidental carcinoma of the gallbladder (IGBC) after cholecystectomy through a meta-analysis. This meta-analysis included 51 studies and 436,636 patients with cholecystectomy. The incidence rate of IGBC after cholecystectomy was 0.6% (95% confidence interval (CI) 0.5–0.8%). The incidence rate of recent studies was not significantly different from those of past studies. The mean age and female ratio of the IGBC subgroup were not significantly different from those of the overall patient group. The estimated rates of IGBC were 13.0%, 34.1%, 39.7%, 22.7%, and 12.5% in the pTis, pT1, pT2, pT3, and pT4 stages, respectively. Patients with IGBC had a favorable overall survival rate compared to patients with non-IGBC (hazard ratio (HR) 0.574, 95% CI 0.445–0.739). However, there was no significant difference of disease-free survival between the IGBC and non-IGBC subgroups (HR 0.931, 95% CI 0.618–1.402). IGBC was found in 0.6% of patients with cholecystectomy. The prognosis of patients with IGBC was favorable compared to those with non-IGBC. In the pathologic examination after cholecystectomy for benign diseases, a sufficient examination for histology should be guaranteed to detect IGBC.
Objective To investigate the effectiveness of radiation protection offered by a newly designed mobile shield barrier for medical personnel during endoscopic retrograde cholangiopancreatography (ERCP). Design Quasi-experimental prospective study. Setting ERCP procedures conducted between October 2016 and June 2017 at a single secondary referral hospital that performs approximately 250 therapeutic ERCP procedures annually. Interventions The mobile shield barrier was a custom-made 2 mm Pb shielding plate (width: 120 cm, height: 190 cm) with a 0.5 mm Pb window (width: 115 cm, height: 60 cm) on its upper part was used. Four wheels were attached to the bottom to allow easy moving. Primary and secondary outcome measures The radiation doses were measured during ERCP using personal thermoluminescence dosimetry (TLD) badges on both sides of the mobile shield barrier (patient’s side: TLD1 and medical staff’s side: TLD2). The radiation doses were also measured on the outer surface of the thyroid shield of the endoscopist (TLD3), and on the chest area inside the protective apron of the endoscopist (TLD4) and the main assistant (TLD5). The TLD was changed and reported once every 3 months. The radiation dose measured by TLD badges were compared. Results During the study period, a total of 128 ERCP procedures were performed. The mean fluoroscopy time per procedure was 244.9±257.0 s and the mean number of digital radiographs per procedure was 3.7±1.0. TLD1 (outside the barrier) had a mean radiation dose of 26.85±3.47 mSv and all the other TLDs (inside the barrier) had less than 1 mSv (p<0.001). In the post hoc analysis, the difference between TLD1 and others showed a statistical significance; however, there were no significant differences between the TLDs inside the barrier. Conclusion Our mobile shield barrier was useful to reduce the radiation exposure of medical personnel during ERCP.
28 January 2016 in Journal of Gastroenterology and Hepatology