Miguel Vivert

Dr. Miguel Vivert

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
MVMiguel Vivert
Miguel Vivert
RDRafael Diez
Rafael Diez
MCMarc Cousineau
Marc Cousineau
DCDiego Bernal Cobaleda
Diego Bernal Cobaleda
Diego PatinoDiego Patino
Diego Patino
Philippe LADOUXPhilippe LADOUX
Philippe LADOUX
Selective Harmonics Elimination is a high-efficiency modulation method for multilevel inverters that allows handling very high voltage applications. It eliminates the most significant harmonics and fixes the desired fundamental component. The main issue of these techniques is the complex process to obtain the appropriate switching-angles, being necessary to calculate them offline, meaning that if some disturbances occur, the system will not be compensated. This article proposes a real-time selective harmonic elimination for a single-phase cascaded multilevel inverter. The control strategy maintains constant the fundamental component of the output voltage while removing its third, fifth, and seventh order harmonics. The switching-angles are dynamically adapted to compensate for variations in the input voltage and the load. This is done by obtaining a virtual dynamic system using Groebner basis, an adaptation of the Newton-Raphson method, and implementing a digital PI controller into the virtual dynamical model. This adaptive modulation technique is validated experimentally in a 200 W, 9-levels Cascaded Full Bridge Inverter, canceling the harmonics and regulating the fundamental components in all the tests. The developed theory can be adapted or extended for any multilevel inverter modulated by selective harmonic elimination.

28 September 2021 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
MVMiguel Vivert
Miguel Vivert
MCMarc Cousineau
Marc Cousineau
PLPhilippe Ladoux
Philippe Ladoux
Joseph FabreJoseph Fabre
Joseph Fabre
MMMiguel Mannes-Hillesheim
Miguel Mannes-Hillesheim
Diego PatinoDiego Patino
Diego Patino
This article presents a decentralized control strategy for the balancing of the cell voltages of a flying capacitor multilevel converter, implementing a large number of cells to address a high conversion ratio. The originality of this article is that no reference is required for regulating the capacitor voltages leading to an auto-balance capability. It is composed of several local cell-voltage balancing controllers and a global load-current regulator. For theoretical analysis purposes, a change of state variables is proposed, leading to a new model of the converter. Then, the study of the decentralized balancing method is performed based on a modal analysis of the system. A decoupling of the output current regulation and the cell-voltage balancing loops is proposed, and then observed. The synthesis of the controllers, guaranteeing the stability of the system within a large bandwidth for each mode, is obtained. To address the fault-tolerance requirement, this decentralized control strategy provides an opportunity for auto-reconfiguration, allowing changes in the number of active cells during operation. Simulations of the separated modal responses show the stability and bandwidth of the control loops for dc/dc 500 to 16 V high conversion ratio applications. Experimental results, performed on a 5-cell multilevel converter, demonstrate the validity of the proposed control method.

19 September 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MVMiguel Vivert
Miguel Vivert
Diego PatinoDiego Patino
Diego Patino
RDRafael Diez
Rafael Diez
This article deals with the modulation and control of a Trinary Hybrid Multilevel Inverter (THMI), which is a cascade multilevel converter that maximizes the number of levels per Full Bridge. The modulation presented defines the duty cycle of switches as piece-wise functions of the desired output voltage, minimizing the processing time. In order to control this converter, it is modeled, as a linear system with bounded disturbance. A Quasi-Sliding Mode Control (QSMC) is designed, simulated, and experimentally verified for the THMI operating in grid-tie mode obtaining better results when compared to a classic PI controller.

26 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
MVMiguel Vivert
Miguel Vivert
RDRafael Diez
Rafael Diez
MCMarc Cousineau
Marc Cousineau
DCDiego Bernal Cobaleda
Diego Bernal Cobaleda
Diego PatinoDiego Patino
Diego Patino
This article presents a decentralized control technique applied to a Cascaded Full-Bridge Multilevel Converter (CFBMC) to balance the amount of power provided by its independent cells connected in series. It is based on the use of elementary modular controllers, associated with each converter cell, communicating with their close neighbors to obtain the appropriate power balancing. A complete theoretical study of the system is provided in terms of modal responses, feedback loop bandwidth and stability criteria and the design method of the correctors is explained as well. Each modular controller can be dynamically removed or added to allow reconfiguration of the number of converter cells during operation for functional safety purposes. This method is illustrated with a five-cell CFBMC, studied both with simulations and experimental tests. The response of the system to load transients and cell voltage disturbances demonstrates the robustness of the proposed control method. Thanks to its modularity, the number of voltage levels of the converter can be easily increased by inserting new cells in series without adding complexity to the control part.

3 April 2026
Verified
Thesis
Closed access
MVMiguel Vivert
Miguel Vivert
Élimination Sélective Adaptative des Harmoniques et Stratégies Décentralisées de Contrôle des Convertisseurs Multiniveaux: La recherche propose quelques améliorations de l’efficacité, de la robustesse, de l’équilibrage des cellules et de la capacité de tolérance aux pannes des convertisseurs multicellulaires. Ce travail est divis´e en deux ´étapes. La première étape propose une méthode de contrôle des convertisseurs multicellulaires pour équilibrer les variables de cellule, réguler la variable de sortie et donner au convertisseur la possibilité d’insérer ou de retirer des cellules pendant le fonctionnement. Le contrôleur est compos´e de trois sections, un contrôleur d’équilibrage, un régulateur global et un système de dérivation. Le contrôleur d’équilibrage compare la variable de cellule avec la variable de cellule des voisins et compense l’erreur avec un contrôleur classique. Le régulateur global est un contrôleur classique qui régule la variable de sortie avec la référence souhait´ee, et le système de bypass permet de sauter une cellule lorsque la cellule n’est pas disponible. Cette commande est implémentée dans le convertisseur multiniveau `a condensateur volant et un convertisseur multiniveau en pont complet en cascade. Dans le convertisseur multiniveau `a condensateur volant, l’objectif est d’équilibrer les tensions des cellules et de réguler le courant de sortie. Le contrôleur dissocie complètement les tensions de cellule et la variable de sortie, ce qui permet que les perturbations dans la variable de cellule ne perturbent pas la variable globale et vice-versa. Des tests de simulation et expérimentaux valident les performances de la théorie de la méthode de contrôle dans cette topologie. Dans le convertisseur multiniveau `a pont complet en cascade, l’objectif est d’équilibrer la tension de sortie des ponts complets et de réguler le courant de sortie du convertisseur. Dans ce cas, le contrôleur délie la variable de sortie des variables de cellule. En revanche, la variable de cellule dépend du contrevaleur d’équilibrage qui équilibre les variables de cellule et du régulateur global qui fixe la trajectoire des tensions de cellule. Les résultats développés en simulation et expérimentations valident la méthode de contrôle dans le convertisseur multiniveau à pont complet en cascade, ayant de bonnes réponses dans tous les tests. L’autre contribution de la recherche correspond `a une loi de contrôle pour tout onduleur multiniveau symétrique modulé par une stratégie d’élimination harmonique sélective. En règle générale, lorsqu’une stratégie de modulation `a basse fréquence est mise en œuvre, il n’y a pas de rétroaction pour ajuster les angles de commutation en raison de la complexité du processus mathématique. La conception de ce contrôleur est basée sur l’obtention d’un système d’équations polynomiales et sa conversion en sa base Groebner du système. Pour trouver les racines du système polynomial, obtenues par la conversion de base Groebner, une adaptation de la méthode Newton Raphson est implémentée, émulant un système dynamique virtuel. De plus, un contrôleur PI est implémenté pour compenser l’erreur entre les harmoniques détectées et la référence harmonique lorsqu’une perturbation est produite. Ce contrôleur est validé en simulation et expérimentation, perturbant certains paramètres, présentant de bonnes réponses dans tous les tests.

13 March 2023 in Preprints.org
Verified
Preprint
Open access
MVMiguel Vivert
Miguel Vivert
RDRafael Diez
Rafael Diez
MCMarc Cousineau
Marc Cousineau
DCDiego Bernal Cobaleda
Diego Bernal Cobaleda
Diego PatinoDiego Patino
Diego Patino
In modern inverter applications, multilevel converters are used thanks to their capability of reducing the passive fi lter volumes, improving the overall THD, sharing the power sources across the several converter cells, and providing a reconfi guration ability in case of failure. However, increasing the number of cells makes more complex the control of the converter. This article proposes a decentralized control technique based on the use of elementary modular controllers, associated with each converter cell and communicating with their close neighbors to obtain the balancing of the powers they supplied. Each modular controller can be dynamically removed or added to allow reconfi guration of the converter for functional safety purpose. This method is applied to a 240V/3A 5-cells Cascaded Full-Bridge Multilevel Converter. The response of the system to load transients and cell voltage disturbances demonstrates the robustness of the proposed decentralized control method. Thanks to the use of modular controllers, the number of levels of the converter can be extended to the order N without adding complexity to its control.