Poly(vinylidene fluoride – tryfluorethylene) [P(VDF-TrFE)] copolymers were mixed with zirconia nanoparticles. The investigation was conducted with the intention to produce nanocompounds with potential to be used as protective patient shielding in radiological procedures. Polymer based nanocomposites with 1, 2, 3, 5 and 10 wt% of ZrO2 nanoparticles were prepared using sol-gel route with zirconium butoxide as the precursor for zirconium oxide nanoclusters. UV-Vis and FTIR spectrometry and differential scanning calorimetry (DSC) were used to characterize the composite samples. We observed a more homogeneous distribution of ZrO2 nanoparticles encapsulated by methyl methacrylate (MMA) into the polymeric matrix, when compared to composites made without the use of surface modifiers from methacrylate group. Apparently, this property is related to the absence of the strong MMA absorption band at 1745 cm-1, attributed to C=O bond, in the P(VDF-TrFE)/ZrO2-MMA nanocomposites. The radiation damage due to high dose exposuring was performed for gamma doses ranging from 100 kGy to 1,000 kGy. The radiation shielding characterization conducted using x-rays with effective energy of 40 keV has demonstrated that composites with 10% of ZrO2,and only 1.0 mm thick, can attenuate 60% of the x-rays beam.
This investigation has been performed to test the feasibility of using K2YF5:Tb3+ crystals as thermoluminescence dosemeters (TLD). K2YF5 single crystals doped with 0.2, 10.0 and 50.0 at.% of trivalent optically active Tb3+ ions as well as K2TbF5 and undoped K2YF5 crystals have been synthesized under hydrothermal conditions. Polished crystal platelets with thickness of about 1 mm have been irradiated with X and gamma rays in order to study thermoluminescent (TL) sensitivity as well as dose and energy response in terms of the Tb3+ concentration in K2YF5. Within this concentration series, K2YF5 crystals doped with 10.0 at.% Tb3+ have been found to have maximum TL response due to a broad asymmetric TL glow peak at 269°C with good linearity of dose response and reproducibility of dose measurements. After deconvolution, the main dosimetric peak has been revealed to be composed of two individual peaks, both with linear TL response behaviour, centered at 210 and 269°C. As it has been proved, the linear TL signal coefficient for K2Y0.9Tb0.1F5 is almost 10 times greater than that for commercial TLD-100 (LiF:Mg,Ti), irradiated with a 137Cs gamma radiation source at the same conditions. The reported results indicate that K2YF5 crystals doped with Tb3+ have potential as promising materials for radiation dosemeters.