Lun Ye

Prof. Lun Ye

Beijing University of Posts and Telecommunications
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2021 in Crystals
Verified
Journal Article
Open access
PDF file
Lun YeLun Ye
Lun Ye
XLXiao Liu
Xiao Liu
DPDanyang Pei
Danyang Pei
JPJing Peng
Jing Peng
SLShuchang Liu
Shuchang Liu
Daquan YangDaquan Yang
Daquan Yang
In this paper, we propose and numerically demonstrate a novel cascaded silicon-on-insulator (SOI) photonic crystal nanobeam cavity (PCNC) dual-parameter sensor for the simultaneous detection of relative humidity (RH) and temperature. The structure consists of two independent PCNCs supporting two different resonant modes: a dielectric-mode and an air-mode, respectively. The dielectric-mode nanobeam cavities (cav1) are covered with SU-8 cladding to increase the sensitivity ratio contrast between RH sensing and temperature sensing. The air-mode nanobeam cavities (cav2) are coated with a water-absorbing polyvinyl-alcohol (PVA) layer that converts the change in RH into a change in refractive index (RI) under different ambient RH levels, thereby inducing a wavelength shift. Due to the positive thermo-optic (TO) coefficient of silicon and the negative TO coefficient of SU-8 cladding, the wavelength responses take the form of a red shift for cav2 and a blue shift for cav1 as the ambient temperature increases. By using 3D finite-difference time-domain (3D-FDTD) simulations, we prove the feasibility of simultaneous sensing by monitoring a single output transmission spectrum and applying the sensor matrix. For cav1, the RH and temperature sensitivities are 0 pm/%RH and −37.9 pm/K, while those of cav2 are −389.2 pm/%RH and 58.6 pm/K. The sensitivity ratios of temperature and RH are −1.5 and 0, respectively, which is the reason for designing two different resonant modes and also implies great potential for realizing dual-parameter sensing detection. In particular, it is also noteworthy that we demonstrate the ability of the dual-parameter sensor to resist external interference by using the dual wavelength matrix method. The maximum RH and temperature detection errors caused by the deviation of resonance wavelength 1 pm are only 0.006% RH and 0.026 K, which indicates that it achieves an excellent anti-interference ability. Furthermore, the structure is very compact, occupying only 32 μm × 4 μm (length × width). Hence, the proposed sensor shows promising prospects for compact lab-on-chip integrated sensor arrays and sensing with multiple parameters.