Based on the real-time environmental constraints in urban regional construction, this paper constructed a bi-level decentralized low-carbon optimal dispatching model of the urban regional integrated energy system (RIES), including the park integrated energy systems (IESs). In this model, a bi-level optimal allocation model of carbon emission constraints between the urban and the park is proposed for the first time. The upper urban will formulate the real-time carbon emission constraints based on real-time environmental monitoring, decomposing the historical carbon emissions to the lower park IESs; the lower park will meet the real-time carbon emission constraints during optimization. We through the upper urban with the lower park between the bi-level decentralized optimization to ensure that the objective function’s upper urban power, natural gas, and heat distribution network system is minimum total network loss. In addition, it is necessary to ensure the minimum operating cost of each park IESs and focus on how to meet the requirements of the overall environment of urban RIES. Furthermore, we study the influence of optimal allocation strategy of carbon emission constraints on network loss, and operating cost of urban RIES under different scenarios. Then, an improved analytical target cascading (ATC) method is applied to solve the bi-level decentralized optimal dispatching model of urban RIES. Finally, an example under three different scenarios is given to verify the superiority and effectiveness of the proposed model and the improved method.
18 August 2022 in Wireless Communications and Mobile Computing
In the distribution network, the addition of distributed power sources can improve the voltage part of the distribution system, provide uninterrupted power supply, and reduce network losses. The location of the power supply and its output will also directly affect the system voltage and power loss. Therefore, determining the optimal installation location and capacity of distributed power generation is of great significance to the distribution network. However, in the actual system, due to the unbalanced load distribution and the three-phase unbalance of the transmission line, the power distribution system presents the characteristics of unbalanced distribution. As the number of electric vehicles increasing, the imbalance of the distribution network has become more prominent.
Regenerative electric heating has gradually become one of the main forms of winter heating with the promotion of “coal to electricity” project. By fully exploiting its regulating capacity, it can effectively achieve a win–win situation of “peak shaving and valley filling” on the grid side and “demand response” on the customer side. In order to meet the different heating demands of users, a regenerative electric heating optimization and control strategy is proposed, taking into account the difference in users’ thermal comfort. Firstly, the reasons for the difference in user thermal comfort are analyzed, and the differentiated preference factors are calculated based on the maximum likelihood estimation method to design differentiated heating schemes. Then, a dynamic optimization and control model for regenerative electric heating with comfort and economic evaluation indicators is established and solved by using quantum genetic algorithm. Finally, a numerical example is used for simulation analysis. The research results show that the strategy proposed in this paper can take into account the comfort of customers and the economy of peaking and low load shifting, so that the operation of regenerative electric heating can respond to the different needs of different customer groups, and realize flexible adjustment at any time of the day.
1 December 2020 in IOP Conference Series: Earth and Environmental Science
Energy storage has the advantages of fast response and accurate power tracking when participates in frequency modulation. By dividing the Area Control Error (ACE) and battery’s State of Charge (SOC) into different regions, combining them with four different emergency frequency modulation states, this paper proposes a partition coordinated control strategy for energy storage to participate in frequency modulation. According to the regional interconnected system, the model of energy storage participating in power grid frequency modulation is built in MATLAB/Simulink. Based on the conventional control and the partition coordinated control, the frequency waveform analyzed. The results show that the energy storage participating in frequency modulation can effectively shorten the regulation time and reduce the frequency fluctuation. The fuzzy control used to optimize the partition coordinated control strategy to make the whole link have better frequency modulation ability.
26 March 2021 in Security and Communication Networks
Cogeneration units use heat and electricity as the main operation mode in the heating season. It suffers the lack of peak shaving ability, resulting in intense wind curtailment. This study presents a coordinated scheduling strategy of heat storage thermoelectric units considering the uncertainty of wind power. The developed method performs a wind power data measurement and process system based on edge computing and deep learning to acquire operation data quickly and independently and adopts a wind power prediction method based on interval scenario. Furthermore, the coordinated control model of the thermal storage unit is established after the analysis of the characteristics of coordinated scheduling strategy of heat storage thermoelectric units based on wind heat complementation, and then the improved particle swarm optimization (PSO) is adopted to the solving process. The proposed method is verified by applying it to two typical thermal power units.