Franck Brachelet

Dr. Franck Brachelet

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sam Ang KeoSam Ang Keo
Sam Ang Keo
Barbara SzymanikBarbara Szymanik
Barbara Szymanik
CRClaire Le Roy
Claire Le Roy
FBFranck Brachelet
Franck Brachelet
DDDidier Defer
Didier Defer
This research paper presents the application of the microwave infrared thermography (MIRT) technique for the purpose of detecting and characterizing defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. Initially, a numerical model was constructed, which consisted of a broadband pyramidal horn antenna and the specimen. The present study investigated the application of a 360 W power system that operated at a frequency of 2.4 GHz, specifically focusing on two different operational modes: continuous and modulated. The specimen being examined consisted of a solid concrete slab that was coated with an adhesive layer, which was then overlaid with a layer of CFRP. Within the adhesive layer, at the interface between the concrete and CFRP, there was a defect in the form of an air gap. The study examined three distinct scenarios: a sample without any defects, a sample with a defect positioned at the center, and a sample with a defect positioned outside the center. The subsequent stage of the investigation incorporated experimental verification of the numerical modeling results. The experiment involved the utilization of two concrete specimens reinforced using CFRP, one without any defects and the other with a defect. Numerical modeling was used in this study to analyze the phenomenon of microwave heating in complex structures. The objective was to evaluate the selected antenna geometry and determine the optimal experimental configuration. Subsequently, these findings were experimentally validated. The observations conducted during the heating phase were particularly noteworthy, as they differed from previous studies that only performed observation of the sample after the heating phase. The results show that MIRT has the potential to be utilized as a method for identifying defects in concrete structures that are reinforced with CFRP.

20 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Barbara SzymanikBarbara Szymanik
Barbara Szymanik
Sam Ang KeoSam Ang Keo
Sam Ang Keo
FBFranck Brachelet
Franck Brachelet
DDDidier Defer
Didier Defer
This study presents the utilization of the microwave infrared thermography (MIRT) technique to identify and analyze the defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. At first, a set of numerical models was created, comprising the broadband pyramidal horn antenna and the analyzed specimen. The utilization of the system operating at a power of 1000 W in a continuous mode, operating at frequency of 2.45 GHz, was analyzed. The specimen under examination comprised a compact concrete slab that was covered with an adhesive layer and, thereafter, topped with a layer of CFRP. An air gap represented a defect at the interface between the concrete and the CFRP within the adhesive layer. In the modeling stage, the study investigated three separate scenarios—a sample with no defects, a sample with a defect located at the center, and a sample with a numerous additional random defects located at the rim of the CFRP matte—to analyze the effect of the natural reinforcement degradation in this area. The next phase of the study involved conducting experiments to confirm the results obtained from numerical modeling. In the experiments, the concrete sample aged for 10 years with the defect in the center and naturally developed defects at the CFRP rim was used. The study employed numerical modeling to explore the phenomenon of microwave heating in complex structures. The aim was to assess the chosen antenna design and identify the most effective experimental setup. These conclusions were subsequently confirmed through experimentation. The observations made during the heating process were particularly remarkable since they deviated from earlier studies that solely conducted measurements of the sample post-heating phase. The findings demonstrate that MIRT has the capacity to be employed as a technique for detecting flaws in concrete structures reinforced with CFRP.

30 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sam Ang KeoSam Ang Keo
Sam Ang Keo
FBFranck Brachelet
Franck Brachelet
DDDidier Defer
Didier Defer
FBFlorin Breaban
Florin Breaban
Concrete cover has an important role in reinforced concrete (RC) structures because it protects reinforcement bars from the bad effects of weather, fire, and bad environmental conditions that cause the corrosion of the reinforcements. Although it is an essential parameter to be considered for structural health monitoring (SHM), its detection by infrared thermography, especially in the heating phase, has not been accessed yet. The detailed analysis and discussions of physical phenomena, known as diffraction and interference, affecting the thermograms during the detection of the steel bars by microwave thermography have given an essential key for resolving this issue. The present paper proposes an innovative methodology with microwave thermography for determining the concrete cover thickness of one-layer reinforcements (12 mm in diameter and regularly placed at 10 cm) in an RC wall (1 m × 1 m × 6.5 cm). By using the transmission approach with five angles of microwave antenna direction (0°, 15°, 30°, 45°, and 60°) and the Snell–Descartes law and linear law, the proposed methodology leads us to deduce the approximate value of the concrete cover thickness (37.74 mm), which is close to the real value (38 mm), as well as the spacing of the steel bars and dielectric constant of the concrete. The detection of the concrete cover thickness is another new remarkable achievement of infrared thermography methods.

24 November 2021 in Buildings
Verified
Journal Article
Open access
PDF file
EBElorn BITEAU
Elorn BITEAU
DDDidier Defer
Didier Defer
FBFranck Brachelet
Franck Brachelet
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
An in situ estimation of the thermal properties of bio-sourced building wall insulation components is of critical importance in improving both the energy efficiency of buildings and the development of construction materials with a smaller environmental footprint. Depending on weather conditions, passive methods are not always feasible; they require time to conduct lengthy testing and may lead to significant uncertainties. This article presents an active method based on power dissipation via flat electrical resistance. The method can be implemented regardless of outdoor weather conditions and is suitable for walls with high overall thermal resistance for which the small average component of the through flow is difficult to estimate. Measurements are conducted of both wall input flows and temperatures. An inverse method, derived from a finite difference model of 1D transfers along with a multi-objective approach, enables the characteristics of a two-material assembly to be identified. A multi-objective method was chosen to solve the problems of high correlation between the thermal parameters of the model. However, the method requires the use of two temperature sensors integrated inside the wall. Following a laboratory validation phase on a PVC/plasterboard assembly, the method is implemented on an actual wall. A coating/hemp concrete assembly is also characterized as part of this work program. The thermal conductivity of the hemp concrete block was estimated at 0.12 W m−1 K−1 and is consistent with values found in the literature.

29 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Barbara SzymanikBarbara Szymanik
Barbara Szymanik
MKMaja Kocoń
Maja Kocoń
Sam Ang KeoSam Ang Keo
Sam Ang Keo
FBFranck Brachelet
Franck Brachelet
DDDidier Defer
Didier Defer
Non-destructive evaluation of reinforced concrete structures is essential for effective maintenance and safety assessments. This study explores the combined use of active microwave thermography and deep learning to detect and localize steel reinforcement within concrete elements. Numerical simulations were developed to model the thermal response of reinforced concrete subjected to microwave excitation, generating synthetic thermal images representing the surface temperature patterns of reinforced concrete, influenced by subsurface steel reinforcement. These images served as training data for a deep neural network designed to identify and localize rebar positions based on thermal patterns. The model was trained exclusively on simulation data and subsequently validated using experimental measurements obtained from large-format concrete slabs incorporating a structured layout of embedded steel reinforcement bars. Surface temperature distributions obtained through infrared imaging were compared with model predictions to evaluate detection accuracy. The results demonstrate that the proposed method can successfully identify the presence and approximate location of internal reinforcement without damaging the concrete surface. This approach introduces a new pathway for contactless, automated inspection using a combination of physical modeling and data-driven analysis. While the current work focuses on rebar detection and localization, the methodology lays the foundation for broader applications in non-destructive testing of concrete infrastructure.

29 November 2025 in International Journal of Thermal Sciences
Verified
Journal Article
Open access
MAMarwan Assaf
Marwan Assaf
FBFranck Brachelet
Franck Brachelet
PTPierre Tittelein
Pierre Tittelein
DDDidier Defer
Didier Defer
EAEmmanuel Antczak
Emmanuel Antczak