In this paper, a Flower Pollination Algorithm (FPA) has been proposed for relieving congestion in the deregulated power electricity industry. Congestion in the power market is one the contemplative challenges to be overcome in the era of deregulation. The primary cause of congestion is due to the loss of the transmission line, an increase in load, or loss of generator(s). Hence, managing congestion is one of the issues which have to be tackled in the present scenario. There are several techniques to relieve congestion. It is quite well-known that the thermal limits of transmission lines in a power system are fixed. One of the methods to abate congestion is to reschedule the real power of the generators. The purpose of the present work is to benefit the Independent System Operator (ISO) in reliving congestion. (1) In order to meet this objective effectively, a FPA algorithm has been proposed for relieving congestion and is simulated on a modified IEEE 30-bus system initially. (2) Congestion cost, compared with and without the application of FPA, is computed. (3) To validate its effectiveness, the obtained results are compared with recent power system optimization algorithms present in the literature. (4) Further, the work has been extended with the incorporation of a Pumped Hydro Storage Unit (PHSU). Here an economic analysis of congestion cost reduction employing FPA before and after the incorporation of PHSU is investigated applying FPA. In comparison with other evolutionary algorithms, the uniqueness of generating a new population is attained in FPA by the levy flight procedure. It is one of the latest evolved algorithms and is suited for different power system problem due to fewer clear-cut tuning parameters in contrast with other algorithms. (5) Furthermore, the effects of other network parameters, including system losses and voltage, has been computed. The result obtained is tested in terms of congestion mitigation with and without the incorporation of PHSU, in terms of novel objective improvement, and with and without applying recently evolving FPA for the above application. Thus the objective-wise and algorithmic-wise innovative concept has been presented. This proves effectiveness of the algorithm in terms of minimized cost convergence and other parameter including system losses and voltage before and after the incorporation of PHSU as compared with other recent trendsetting reported optimization techniques.
Demand Side Management (DSM) is an effective tool for utilities through reducing the demand of peak load and controlling the utilization of the energy of the system. The implementation of DSM provides benefits for utilities and is profitable for the customers who are involved in this process. DSM based on a load shifting strategy is proposed in this paper by employing various devices to minimize the energy consumption pattern in the system. The proposed hybrid strategy is the joint implementation of the Wingsuit Flying Search Algorithm (WFSA) and Artificial Cell Swarm Optimization (ACSO). The searching behavior of WFSA is enhanced by ACSO. Hence, it is named the WFS2ACSO technique. The implementation of this load shifting technique was carried out on three different types of loads, these being residential loads, commercial loads, and industrial loads. Two case studies, over summer and winter, were validated to check the feasibility of the test system. The proposed method aimed to achieve the load demand in an effective way for the minimization of bill electrification, Peak to Average Ratio (PAR), and the consumption of power. The Time-of-Use (TOU) pricing was implemented to calculate the savings in energy bills. The proposed test system of the Micro Grid (MG) was executed on a MATLAB platform with two case studies based on the optimization methods WFSA and WFS2ACSO. Simulation results demonstrated the comparative analysis of electricity cost and peak load with different algorithms and were carried out with and without DSM consideration. The projected DSM methodology achieved considerable savings as the peak load demand of MG decreased. Furthermore, the decrease in PAR levels of 14% in the residential load, 16% in the commercial load, and 10% in the industrial load, with and without the DSM methodology, was presented. The flight length and awareness of probability tuning parameters make the proposed algorithm more effective in obtaining better results. The test results obtained prove the effectiveness of the hybridized algorithm as compared with other trend-setting optimization techniques such as Particle Swarm Optimization (PSO) and Ant Lion Optimization (ALO).
The drug discovery and design process has been significantly transformed by the integration of data science, artificial intelligence (AI), green chemistry principles, and affordable medicine. AI techniques enable rapid analysis of vast datasets, predicting molecular interactions, optimizing drug candidates, and identifying potential therapeutics. Green chemistry practices promote sustainability and efficiency, resulting in environmentally friendly and cost-effective production processes. The goal is to develop affordable medicines that are not only efficacious but also accessible to a wider population. This chapter explores case studies and emerging trends to highlight the transformation of the pharmaceutical industry and innovation in drug discovery.
Solar stills are zero-emission water desalination devices that utilize the abundantly available solar energy to deliver clean water. In remote locations which are deprived of electricity as well as clean and fresh water, Twin wedge solar stills (TWSS) can be utilized to desalinate saline and brackish water. The productivity of TWSS is depends on the evaporation as well as condensation rate which are subjected to the weather constraints namely, the solar energy radiation, the wind velocity along with the surrounding atmospheric temperature. Monitoring the various temperature parameters in the TWSS and controlling them enables the control of freshwater production. In this paper, the yield of TWSS is monitored and controlled using Seebeck effect-based thermoelectric K-type thermocouple sensors for temperature measurements and reverse seebeck effect based thermoelectric modules for increasing evaporation and condensation rate of the TWSS. A Temperature Control Unit (TCU) is developed to acquire the temperature sensor data and control the operation of thermoelectric modules in order to control the production of the TWSS. The TCU is powered by PV with a battery backup system for remote location operation. The productivity of the system increased from 0.69 – 1.38 liters/m 2 per day to 3.28 – 3.61 liters/m 2 per day, through proposed Temperature Control strategy through Thermoelectric sensors and modules. The proposed system is 1.4 times more profitable than TWSS equivalent to the area of proposed PV powered system.