Silvia Migliari

Dr. Silvia Migliari

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2017 in ACS Omega
Verified
Journal Article
Open access
SMSilvia Migliari
Silvia Migliari
ASAntonino Sammartano
Antonino Sammartano
MSMaura Scarlattei
Maura Scarlattei
GSGiulio Serreli
Giulio Serreli
CGCaterina Ghetti
Caterina Ghetti
Livia RuffiniLivia Ruffini
Livia Ruffini
Background: Prostate-specific membrane antigen (PSMA) has gained high attention as a useful biomarker in the imaging evaluation of prostate cancer with positron emission tomography (PET) during recent years. [68Ga]-labeled Glu-urea-Lys(Ahx)-HBED-CC ([68Ga]-PSMA-HBED-CC) is a novel PSMA inhibitor radiotracer which has demonstrated its suitability in detecting prostate cancer. Preparation conditions may influence the quality and in vivo behavior of this tracer, and no standard procedure for the quality control (QC) is available. The aim of this study was to develop a new rapid and simple high-pressure liquid chromatography method of analysis for the routine QCs of [68Ga]-PSMA-HBED-CC to guarantee the high quality of the radiopharmaceutical product before release. Methods: A stepwise approach was used based on the quality by design concept of the International Conference of Harmonisation Q2 (R1) and Q8 (Pharmaceutical Development) guidelines in accordance with the regulations and requirements of European Association of Nuclear Medicine, Society of Nuclear Medicine, International Atomic Energy Agency, World Health Organization, and Italian Association of Nuclear Medicine and Molecular Imaging. The developed analytical test method was validated because a specific monograph in the pharmacopoeia is not available for [68Ga]-PSMA-HBED-CC. Results: The purity and quality of the radiopharmaceutical obtained according to the proposed method resulted high enough to safely administrate it to patients. An excellent linearity was found between 0.8 and 5 μg/mL, with a detection limit of 0.2 μg/mL. Assay imprecision (% CV) was <2%. Conclusions: The developed method to assess the radiochemical and chemical purity of [68Ga]-PSMA-HBED-CC is rapid, accurate, and reproducible, allowing routinely the use of this PET tracer as a diagnostic tool for imaging prostate cancer and also assuring patient safety.

13 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
SMSilvia Migliari
Silvia Migliari
MSMaura Scarlattei
Maura Scarlattei
GBGiorgio Baldari
Giorgio Baldari
CSClaudia Silva
Claudia Silva
Livia RuffiniLivia Ruffini
Livia Ruffini
Background: Nowadays, in Nuclear Medicine, clinically applied radiopharmaceuticals must meet quality release criteria such as high radiochemical purity and radiochemical yield. Many radiopharmaceuticals do not have marketing authorization and have no dedicated monograph within European Pharmacopeia (Ph. Eur.); therefore, general monographs on quality controls (QCs) have to be applied for clinical application. These criteria require standardization and validation in labeling and preparation, including quality controls measurements, according to well defined standard operation procedures. However, QC measurements are often based on detection techniques that are specific to a certain chromatographic system. Several radiosyntheses of [68Ga]Ga-radiopharmaceuticals are more efficient and robust when they are performed with 2-[4-(2-hydroxyethyl)piperazin-1-yl] ethanesulfonic acid (HEPES) buffer, which is considered as an impurity to be assessed in the QC procedure, prior to clinical use. Thus, Ph. Eur. has introduced a thin-layer chromatography (TLC) method to quantify the HEPES amount that is present in [68Ga]Ga-radiopharmaceuticals. However, this is only qualitative and has proven to be unreliable. Here we develop and validate a new high-performance liquid chromatography (UV-Radio-HPLC) method to quantify the residual amount of HEPES in 68Ga-based radiopharmaceuticals. Method: To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document that was adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. A range of concentrations of HEPES (100, 80, 60, 40, 20, 10, 5, 3 μg/mL) were analyzed. Moreover, to test the validity and pertinence of our new HPLC method, we analyzed samples of [68Ga]Ga-DOTATOC; [68Ga]Ga-PSMA; [68Ga]Ga-DOTATATE; [68Ga]Ga-Pentixafor; and [68Ga]Ga-NODAGA-Exendin-4 from different batches that were prepared for clinical use. Results: In the assessed samples, HEPES could not be detected by the TLC method that was described in Ph. Eur. within 4 min incubation in an iodine-saturated chamber. Our developed HPLC method showed excellent linearity between 3 and 100 μg/mL for HEPES, with a correlation coefficient (R2) for calibration curves that was equal to 0.999, coefficients of variation (CV%) < 2%, and percent deviation value of bias from 100% to 5%, in accordance with acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed and the limit-of-quantification (LOQ) was 3 μg/mL, confirming the high sensitivity of the method. The amount of HEPES that was detected with our developed HPLC method in the tested [68Ga]Ga-radiopharmaceuticals resulted well below the Ph. Eur. limit, especially for [68Ga]Ga-NODAGA-Exendin-4. Conclusions: The TLC method that is described in Ph. Eur. to assess residual HEPES in [68Ga]-based radiopharmaceuticals may not be sufficiently sensitive and thus unsuitable for QC release. Our new HPLC method was sensitive, quantitative, reproducible, and rapid for QCs, allowing us to exactly determine the residual HEPES amount in [68Ga]Ga-radiopharmaceuticals for safe patient administration.

15 January 2022 in Molecules
Verified
Journal Article
Open access
PDF file
SMSilvia Migliari
Silvia Migliari
ASAntonino Sammartano
Antonino Sammartano
MBMarti Boss
Marti Boss
Martin GotthardtMartin Gotthardt
Martin Gotthardt
MSMaura Scarlattei
Maura Scarlattei
Livia RuffiniLivia Ruffini
Livia Ruffini
Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in β-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R–avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 μg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5–0.75 μg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) < 2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% < 2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 μg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.

1 March 2022 in Current Radiopharmaceuticals
Verified
Journal Article
Closed access
PDF file
SMSilvia Migliari
Silvia Migliari
ASAntonino Sammartano
Antonino Sammartano
MSMaura Scarlattei
Maura Scarlattei
GBGiorgio Baldari
Giorgio Baldari
BJBarbara Janota
Barbara Janota
LRLivia Ruffini
Livia Ruffini
Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in β-cells, but it is highly expressed in human insulinomas and gastrinomas. Several GLP-1 receptor–avid radioligands have been developed to image insulin-secreting tumors or to provide a quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4 is a high affinity ligand of the GLP1-R, which is a candidate for being labeled with a PET isotope and used for imaging purposes. Objective: Here, we report the development and validation results of a semi manual procedure to label [Lys40,Nle14(Ahx-NODAGA)NH2]exendin-4, with Ga-68. Methods: A 68Ge/68Ga Generator (GalliaPharma®,Eckert and Ziegler) was eluted with 0.1M HCl on an automated synthesis module (Scintomics GRP®). The peptide contained in the kit vial (Radioisotope Center POLATOM) in different amounts (10-20-30 µg) was reconstituted with 2-[4-(2-hydroxyethyl)piperazin-1-yl]ethansulfonic acid (HEPES) solution and 68GaCl3 (400–900 MBq), followed by 10 min incubation at 95°C. The reaction solution was then purified through an Oasis HLB column. The radiopharmaceutical product was tested for quality controls (CQs), in accordance with the European Pharmacopoeia standards. Results: The synthesis of 68Ga]Ga-NODAGA-Exendin-4 provided optimal results with 10 µg of peptide, getting the best radiochemical yield (23.53 ± 2.4 %), molar activity (100 GBq/µmol) and radiochemical purity (91.69 %). Conclusion: The study developed an imaging tool [68Ga]Ga-NODAGA-Exendin-4, avoiding pharmacological effects of exendin-4, for the clinical community.

6 July 2020
Verified
Journal Article
Open access
ASAntonino Sammartano
Antonino Sammartano
SMSilvia Migliari
Silvia Migliari
MSMaura Scarlattei
Maura Scarlattei
GBGiorgio Baldari
Giorgio Baldari
Livia RuffiniLivia Ruffini
Livia Ruffini
Chemokine receptor-4 (CXCR4) is involved in tumor growth and progression in several types of human cancer. Recently, [68Ga]-DOTA-Pentixafor has been assessed as an excellent imaging probe targeting CXCR4-expression using positron emission tomography (PET). Here we report on the entire production cycle of [68Ga]-DOTA-Pentixafor, including quality control development and process validation. Synthesis of [68Ga]-DOTA-Pentixafor was validated via three independent and consecutive production runs using an automated synthesis system. All validation runs must pass the pre-set quality control (QC) limits. Validation was performed for established QC tests to ensure that methods were reproducible and reliable in routine use. Germanium-68 breakthrough was determined for each sample. Production yield was calculated for each synthesis to assess the performance and efficiency of the radiolabeling process. The quality of the final product was determined by ITLC and HPLC methods after each synthesis. The average ITLC-measured radiochemical purity was above 98.5% and HPLC-measured radiochemical purity was 99.86%, 99,83% and 100% in the three validation runs. Germanium breakthrough was 4.8*10-5%, 4.9*10-5% and 4.7*10-5% of total activity, far below the recommended level of 0.001%. Residual ethanol resulted 5.22%, 5.58% and 5.32%V/V; spot of HEPES impurity was not more intense than spot of reference solution (200µg/V). Endotoxin level resulted <17.5EU/ml. pH of the final product was 7 in all samples. [68Ga]-DOTA-Pentixafor fit requirements of the pre-set quality parameters of purity, efficacy and safety in the batches considered for this study and fulfilled all the acceptance criteria for injectable radiopharmaceutical products. The results demonstrated a batch-to-batch reproducibility providing high radiochemical purity.

28 September 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
DGDonatello Gasparro
Donatello Gasparro
MSMaura Scarlattei
Maura Scarlattei
ESEnrico Maria Silini
Enrico Maria Silini
SMSilvia Migliari
Silvia Migliari
GBGiorgio Baldari
Giorgio Baldari
Livia RuffiniLivia Ruffini
Livia Ruffini
In oligo-metastatic renal cell carcinoma (RCC), neither computed tomography (CT) nor bone scan is sensitive enough to detect small tumor deposits hampering early treatment and potential cure. Prostate-specific membrane antigen (PSMA) is a transmembrane glycoprotein expressed in the neo-vasculature of numerous malignant neoplasms, including RCC, that can be targeted by positron emission tomography (PET) using PSMA-targeting radioligands. Our aim was to investigate whether PSMA-expression patterns of renal cancer in the primary tumor or metastatic lesions on immunohistochemistry (IHC) are associated with PET/CT findings using [68Ga]-PSMA-HBED-CC (PSMA-PET/CT). We then analyzed the predictive and prognostic role of the PSMA-PET/CT signal. In this retrospective single-center study we included patients with renal cancer submitted to PSMA-PET/CT for staging or restaging, with tumor specimens available for PSMA-IHC. Clinical information (age, tumor type, and grade) and IHC results from the primary tumor or metastases were collected. The intensity of PSMA expression at IHC was scored into four categories: 0: none; 1: weak; 2: moderate; 3: strong. PSMA expression was also graded according to the proportion of vessels involved (PSMA%) into four categories: 0: none; 1: 1–25%; 2: 25–50%; 3: >50%. The intensity of PSMA expression and PSMA% were combined in a three-grade score: 0–2 absent or mildly positive, 3–4 moderately positive, and 5–6 strongly positive. PSMA scores were used for correlation with PSMA-PET/CT results. Results: IHC and PET scans were available for the analysis in 26 patients (22 ccRCC, 2 papillary RCC, 1 chromophobe, 1 “not otherwise specified” RCC). PSMA-PET/CT was positive in 17 (65%) and negative in 9 patients (35%). The mean and median SUVmax in the target lesion were 34.1 and 24.9, respectively. Reporter agreement was very high for both distant metastasis location and local recurrence (kappa 1, 100%). PSMA-PET detected more lesions than conventional imaging and revealed unknown metastases in 4 patients. Bone involvement, extension, and lesion number were greater than in the CT scan (median lesion number on PET/CT 3.5). The IHC PSMA score was concordant in primary tumors and metastases. All positive PSMA-PET/CT results (15/22 ccRCC, 1 papillary cancer type II, and 1 chromofobe type) were revealed in tumors with strong or moderate PSMA combined scores (3–4 and 5–6). In ccRCC tissue samples, PSMA expression was strong to moderate in 20/22 cases. The SUVmax values correlated to the intensity of PSMA expression which were assessed using IHC (p = 0.01), especially in the ccRCC subgroup (p = 0.009). Median survival was significantly higher in patients with negative PSMA-PET/CT (48 months) compared to patients with a positive scan (24 months, p= 0.001). SUVmax ≥ 7.4 provides discrimination of patients with a poor prognosis. Results of PSMA-PET/CT changed treatment planning. Conclusions: in renal cancer, positive PSMA-PET/CT is strongly correlated to the intensity of PSMA expression on immunohistochemistry in both ccRCC and chromophobe cancer. PSMA-PET/CT signal predicts a poor prognosis confirming its potential as an aggressiveness biomarker and providing paramount additional information influencing patient management.