Eva A Rog-Zielinska

Dr. Eva A Rog-Zielinska


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2021 in Circulation Research
Verified
Journal Article
Open access
PDF file
EREva A Rog-Zielinska
Eva A Rog-Zielinska
MSMarina Scardigli
Marina Scardigli
Remi PeyronnetRemi Peyronnet
Remi Peyronnet
CZCallum Zgierski-Johnston
Callum Zgierski-Johnston
Joachim GreinerJoachim Greiner
Joachim Greiner
PKPeter Kohl
Peter Kohl
Rationale: The sarcolemma of cardiomyocytes contains many proteins that are essential for electromechanical function in general, and excitation-contraction coupling in particular. The distribution of these proteins is nonuniform between the bulk sarcolemmal surface and membrane invaginations known as transverse tubules (TT). TT form an intricate network of fluid-filled conduits that support electromechanical synchronicity within cardiomyocytes. Although continuous with the extracellular space, the narrow lumen and the tortuous structure of TT can form domains of restricted diffusion. As a result of unequal ion fluxes across cell surface and TT membranes, limited diffusion may generate ion gradients within TT, especially deep within the TT network and at high pacing rates. Objective: We postulate that there may be an advective component to TT content exchange, wherein cyclic deformation of TT during diastolic stretch and systolic shortening serves to mix TT luminal content and assists equilibration with bulk extracellular fluid. Methods and Results: Using electron tomography, we explore the 3-dimensional nanostructure of TT in rabbit ventricular myocytes, preserved at different stages of the dynamic cycle of cell contraction and relaxation. We show that cellular deformation affects TT shape in a sarcomere length-dependent manner and on a beat-by-beat time-scale. Using fluorescence recovery after photobleaching microscopy, we show that apparent speed of diffusion is affected by the mechanical state of cardiomyocytes, and that cyclic contractile activity of cardiomyocytes accelerates TT diffusion dynamics. Conclusions: Our data confirm the existence of an advective component to TT content exchange. This points toward a novel mechanism of cardiac autoregulation, whereby the previously implied increased propensity for TT luminal concentration imbalances at high electrical stimulation rates would be countered by elevated advection-assisted diffusion at high mechanical beating rates. The relevance of this mechanism in health and during pathological remodeling (eg, cardiac hypertrophy or failure) forms an exciting target for further research.

22 July 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
EMEilidh A. MacDonald
Eilidh A. MacDonald
JMJosef Madl
Josef Madl
Joachim GreinerJoachim Greiner
Joachim Greiner
ARAhmed F. Ramadan
Ahmed F. Ramadan
SWSarah M. Wells
Sarah M. Wells
TQT. Alexander Quinn
T. Alexander Quinn
The rhythmic electrical activity of the heart’s natural pacemaker, the sinoatrial node (SAN), determines cardiac beating rate (BR). SAN electrical activity is tightly controlled by multiple factors, including tissue stretch, which may contribute to adaptation of BR to changes in venous return. In most animals, including human, there is a robust increase in BR when the SAN is stretched. However, the chronotropic response to sustained stretch differs in mouse SAN, where it causes variable responses, including decreased BR. The reasons for this species difference are unclear. They are thought to relate to dissimilarities in SAN electrophysiology (particularly action potential morphology) between mouse and other species and to how these interact with subcellular stretch-activated mechanisms. Furthermore, species-related differences in structural and mechanical properties of the SAN may influence the chronotropic response to SAN stretch. Here we assess (i) how the BR response to sustained stretch of rabbit and mouse isolated SAN relates to tissue stiffness, (ii) whether structural differences could account for observed differences in BR responsiveness to stretch, and (iii) whether pharmacological modification of mouse SAN electrophysiology alters stretch-induced chronotropy. We found disparities in the relationship between SAN stiffness and the magnitude of the chronotropic response to stretch between rabbit and mouse along with differences in SAN collagen structure, alignment, and changes with stretch. We further observed that pharmacological modification to prolong mouse SAN action potential plateau duration rectified the direction of BR changes during sustained stretch, resulting in a positive chronotropic response akin to that of other species. Overall, our results suggest that structural, mechanical, and background electrophysiological properties of the SAN influence the chronotropic response to stretch. Improved insight into the biophysical determinants of stretch effects on SAN pacemaking is essential for a comprehensive understanding of SAN regulation with important implications for studies of SAN physiology and its dysfunction, such as in the aging and fibrotic heart.

20 June 2019 in JCI Insight
Verified
Journal Article
Open access
PDF file
SBSören Brandenburg
Sören Brandenburg
JPJan Pawlowitz
Jan Pawlowitz
BEBenjamin Eikenbusch
Benjamin Eikenbusch
JPJonas Peper
Jonas Peper
TKTobias Kohl
Tobias Kohl
SLStephan E. Lehnart
Stephan E. Lehnart
Atrial dysfunction is highly prevalent and associated with increased severity of heart failure. While rapid excitation-contraction coupling depends on axial junctions in atrial myocytes, the molecular basis of atrial loss of function remains unclear. We identified approximately 5-fold lower junctophilin-2 levels in atrial compared with ventricular tissue in mouse and human hearts. In atrial myocytes, this resulted in subcellular expression of large junctophilin-2 clusters at axial junctions, together with highly phosphorylated ryanodine receptor (RyR2) channels. To investigate the contribution of junctophilin-2 to atrial pathology in adult hearts, we developed a cardiomyocyte-selective junctophilin-2–knockdown model with 0 mortality. Junctophilin-2 knockdown in mice disrupted atrial RyR2 clustering and contractility without hypertrophy or interstitial fibrosis. In contrast, aortic pressure overload resulted in left atrial hypertrophy with decreased junctophilin-2 and RyR2 expression, disrupted axial junctions, and atrial fibrosis. Whereas pressure overload accrued atrial dysfunction and heart failure with 40% mortality, additional junctophilin-2 knockdown greatly exacerbated atrial dysfunction with 100% mortality. Strikingly, transgenic junctophilin-2 overexpression restored atrial contractility and survival through de novo biogenesis of polyadic junctional membrane complexes maintained after pressure overload. Our data show a central role of junctophilin-2 cluster disruption in atrial hypertrophy and identify transgenic augmentation of junctophilin-2 as a disease-mitigating rationale to improve atrial dysfunction and prevent heart failure deterioration.

1 April 2021 in Journal of Molecular and Cellular Cardiology
Verified
Journal Article
Open access
EREva A Rog-Zielinska
Eva A Rog-Zielinska
RMR. Moss
R. Moss
WKW. Kaltenbacher
W. Kaltenbacher
JGJ. Greiner
J. Greiner
PVP. Verkade
P. Verkade
MCMark B. Cannell
Mark B. Cannell
Detailed knowledge of the ultrastructure of intracellular compartments is a prerequisite for our understanding of how cells function. In cardiac muscle cells, close apposition of transverse (t)-tubule (TT) and sarcoplasmic reticulum (SR) membranes supports stable high-gain excitation-contraction coupling. Here, the fine structure of this key intracellular element is examined in rabbit and mouse ventricular cardiomyocytes, using ultra-rapid high-pressure freezing (HPF, omitting aldehyde fixation) and electron microscopy. 3D electron tomograms were used to quantify the dimensions of TT, terminal cisternae of the SR, and the space between SR and TT membranes (dyadic cleft). In comparison to conventional aldehyde-based chemical sample fixation, HPF-preserved samples of both species show considerably more voluminous SR terminal cisternae, both in absolute dimensions and in terms of junctional SR to TT volume ratio. In rabbit cardiomyocytes, the average dyadic cleft surface area of HPF and chemically fixed myocytes did not differ, but cleft volume was significantly smaller in HPF samples than in conventionally fixed tissue; in murine cardiomyocytes, the dyadic cleft surface area was higher in HPF samples with no difference in cleft volume. In both species, the apposition of the TT and SR membranes in the dyad was more likely to be closer than 10 nm in HPF samples compared to CFD, presumably resulting from avoidance of sample shrinkage associated with conventional fixation techniques. Overall, we provide a note of caution regarding quantitative interpretation of chemically-fixed ultrastructures, and offer novel insight into cardiac TT and SR ultrastructure with relevance for our understanding of cardiac physiology.

10 October 2018 in The Anatomical Record
Verified
Journal Article
Open access
PDF file
EREva A Rog-Zielinska
Eva A Rog-Zielinska
EOE. T. O'TOole
E. T. O'TOole
AHA. Hoenger
A. Hoenger
PKP. Kohl
P. Kohl
Cardiomyocytes both cause and experience continual cyclic deformation. The exact effects of this deformation on the properties of intracellular organelles are not well characterized, although they are likely to be relevant for cardiomyocyte responses to active and passive changes in their mechanical environment. In the present study we provide three‐dimensional ultrastructural evidence for mechanically induced mitochondrial deformation in rabbit ventricular cardiomyocytes over a range of sarcomere lengths representing myocardial tissue stretch, an unloaded “slack” state, and contracture. We also show structural indications for interaction of mitochondria with one another, as well as with other intracellular elements such as microtubules, sarcoplasmic reticulum and T‐tubules. The data presented here help to contextualize recent reports on the mechanosensitivity and cell‐wide connectivity of the mitochondrial network and provide a structural framework that may aide interpretation of mechanically‐regulated molecular signaling in cardiac cells. Anat Rec, 302:146–152, 2019. © 2018 The Authors. The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

1 November 2018 in EP Europace
Verified
Journal Article
Open access
PDF file
EREva A Rog-Zielinska
Eva A Rog-Zielinska
CKCherrie Hei Ting Kong
Cherrie Hei Ting Kong
CZCallum Zgierski-Johnston
Callum Zgierski-Johnston
PVPaul Verkade
Paul Verkade
JMJudith Mantell
Judith Mantell
PKPeter Kohl
Peter Kohl
The ultrastructure of ventricular cardiomyocyte T-tubule connections with the outer cell surface (‘mouth’ regions) has been reported to differ between mice and rabbits. In mice, T-tubule mouths form convoluted narrow spaces filled with electron-dense matter that impedes diffusion between T-tubular lumen and bulk extracellular space. Here, we explore whether T-tubule mouths are also constricted in rat (another murine model used frequently for cardiac research) and whether pig and human T-tubule mouth configurations are structurally more similar to mice or rabbits. We used chemically-fixed tissue and high-pressure frozen isolated cardiomyocytes to compare T-tubule mouth architecture using transmission electron microscopy and three-dimensional electron tomography. We find that rat T-tubular mouth architecture is more similar to that of rabbits than mice, lacking the marked tortuosity and electron-dense ground substance that obstructs access to deeper portions of the T-tubular system in mice. Pilot observations in larger mammals (pig, human) suggest that mouse may be the least representative animal model of T-tubule connectivity with the outer cell surface in larger mammals. Rat T-tubular system architecture appears to be more similar in size and topology to larger mammals than mice. T-tubular mouth topology may contribute to differences in experimental model behaviour, underscoring the challenge of appropriate model selection for research into cell and tissue function.