Thermal stress plays a prominent role in reliability of bushings and contributes to reliability of power transformers, especially during overload conditions. Thus, exploring the temperature distribution in the bushings is essential. This paper proposes a new thermal model to estimate the hot spot temperature (HST) of oil impregnated paper (OIP) bushings based on modified thermal-electrical analogy model. The proposed model is developed based on finite element method (FEM) to accurately model all fluid flow and internal convection as well as the thermal conduction mechanism. To do so, convection thermal resistances are defined, and its non-linear characteristic is calculated for different overloading condition. The proposed approach is applied on a 245kV, 800A OIP bushing to analyze not only the normal loading condition but also short-term overloading beyond the rated current. In addition, the oil flow condition with different load currents and transformer top oil temperatures (TTOT) are investigated. The results show a consistent temperature rise with the typical test conditions with no identified problematic situation. However, during overloading, the temperature rise exceeds beyond the permissible limits recommended by IEEE C57.19. Hence, the overloading of transformers may deteriorate the bushing insulation and reduce its lifetime.
Photovoltaic arrays receive varying levels of solar radiation due to factors such as shadows created by clouds, surrounding buildings, and other obstructions. Therefore, an effective Maximum Power Point Tracking (MPPT) algorithm should be used to maximize power generation from non-uniform arrays. Most MPPT algorithms do not perform well during partial shadow conditions, as they can become trapped in local maxima and fail to identify the absolute global maximum point (GP). This paper proposes a new MPPT approach that combines Perturb & Observe (P&O) and Fuzzy Logic Controller (FLC) with the Particle Swarm Optimization (PSO) algorithm. The FLC algorithm is then used to maximize search accuracy. The configurations of this system and the study results demonstrate the dynamic and promising performance of the proposed method under various environmental and shading conditions. In addition to its simplicity and ease of implementation, the proposed algorithm exhibits high accuracy in tracking the maximum power point. This has been evidenced through both simulation and laboratory results of the hardware.
8 June 2021 in IEEE Transactions on Power Delivery
This paper presents an advanced differential protection scheme for protecting transformers during geomagnetic disturbance (GMD) conditions and the flow of geomagnetically induced current (GIC) in the transformer. In this study, the inaccuracy of the existing harmonic blocking (HB) methods of the differential protection is investigated under the GIC conditions. It is shown that there are scenarios in which the HB-based differential relays fail to clear the internal faults since they are blocked due to the GIC-related harmonic currents. By detecting both GIC conditions and internal short-circuit faults, a solution scheme is proposed which overrides the harmonic inhibition signals issued by the HB module and makes the differential relay capable of tripping the transformer. Extensive time-domain simulations within the EMTP-RV verify the effectiveness of the proposed scheme in (i) unblocking the transformer differential protection for the internal faults during the GIC, (ii) preventing the malfunction for the external faults, (iii) distinguishing the transformer inrush and sympathetic inrush currents from the GIC conditions, and (iv) immunity to current transformer (CT) saturation. Furthermore, the simulation results prove that the differential protection equipped with the proposed approach outperforms the existing HB methods under the GIC conditions.
23 May 2022 in IEEE Transactions on Power Delivery
Harmonic blocking (HB)-based differential relays, generally employed in the transformer protection, are likely to fail to interrupt internal short-circuit faults that occur under geomagnetically induced current (GIC) conditions. This paper proposes a waveform-based approach that enhances the differential protection dependability under the GIC conditions by detecting the GIC and overriding the HB signals for the internal faults. A novel algorithm is developed for the GIC detection, which employs three-phase instantaneous differential current waveforms and recognizes a GIC condition if the waveforms are all asymmetric in one direction. The proposed waveform-based approach also utilizes trip request signals of the differential relay's fault detection module to unblock the relay for the internal faults during the GIC. The results show that the proposed waveform-based approach (i) can successfully unblock the differential protection for the internal faults under the GIC conditions, (ii) does not malfunction for the external faults during the GIC, (iii) discriminates transformer energization cases from the GIC conditions, and (iv) is immune to the measurement noise. The current transformer (CT) saturation is also considered in the studies. The proposed approach's effectiveness is verified for different transformer types, including three-phase and single-phase transformers.
5 October 2022 in IEEE Transactions on Power Delivery
This paper studies the temperature distribution in the transformer bushing in the presence of Geomagnetically Induced Current (GIC). The thermal stress can significantly affect the transformer bushing reliability and lifespan. However, the existing research works have focused on thermal modeling of transformer bushing due to loading, and the impact of GIC on this valuable apparatus has not been investigated yet. In this paper, the hot-spot temperature (HST) in an oil-impregnated paper (OIP) bushing is studied during the GIC. The harmonic currents at various GIC levels are obtained from the EMTP-RV time-domain simulations using a detailed topological transformer model. Based on a frequency-dependent model of the bushing resistance, the total power loss is calculated by taking into account the GIC, load current, and harmonic currents. Subsequently, the temperature distribution in the modeled bushing is obtained from the finite-element method (FEM), considering all thermal mechanisms, including fluid flow, internal convection, and thermal conduction. In addition, a Thermal Equivalent Circuit (TEC) is developed for the bushing that replicates the FEM results. The simulation results reveal that the bushing HST may exceeds the recommended permissible temperature of the IEEE bushing standard. This situation may result in bushing insulation deterioration and reduction of the bushing lifespan.