Chien-Sung Tsai

Chien-Sung Tsai


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2020 in JMIR Medical Informatics
Verified
Journal Article
Open access
Chin-Sheng LinChin-Sheng Lin
Chin-Sheng Lin
CHIN LINCHIN LIN
CHIN LIN
Wen-Hui FangWen-Hui Fang
Wen-Hui Fang
CHChia-Jung Hsu
Chia-Jung Hsu
SCSy-Jou Chen
Sy-Jou Chen
SLShih-Hua Lin
Shih-Hua Lin
Background: The detection of dyskalemias—hypokalemia and hyperkalemia—currently depends on laboratory tests. Since cardiac tissue is very sensitive to dyskalemia, electrocardiography (ECG) may be able to uncover clinically important dyskalemias before laboratory results. Objective: Our study aimed to develop a deep-learning model, ECG12Net, to detect dyskalemias based on ECG presentations and to evaluate the logic and performance of this model. Methods: Spanning from May 2011 to December 2016, 66,321 ECG records with corresponding serum potassium (K+) concentrations were obtained from 40,180 patients admitted to the emergency department. ECG12Net is an 82-layer convolutional neural network that estimates serum K+ concentration. Six clinicians—three emergency physicians and three cardiologists—participated in human-machine competition. Sensitivity, specificity, and balance accuracy were used to evaluate the performance of ECG12Net with that of these physicians. Results: In a human-machine competition including 300 ECGs of different serum K+ concentrations, the area under the curve for detecting hypokalemia and hyperkalemia with ECG12Net was 0.926 and 0.958, respectively, which was significantly better than that of our best clinicians. Moreover, in detecting hypokalemia and hyperkalemia, the sensitivities were 96.7% and 83.3%, respectively, and the specificities were 93.3% and 97.8%, respectively. In a test set including 13,222 ECGs, ECG12Net had a similar performance in terms of sensitivity for severe hypokalemia (95.6%) and severe hyperkalemia (84.5%), with a mean absolute error of 0.531. The specificities for detecting hypokalemia and hyperkalemia were 81.6% and 96.0%, respectively. Conclusions: A deep-learning model based on a 12-lead ECG may help physicians promptly recognize severe dyskalemias and thereby potentially reduce cardiac events.


Da-Wei ChangDa-Wei Chang
Da-Wei Chang
Chin-Sheng LinChin-Sheng Lin
Chin-Sheng Lin
TTTien-Ping Tsao
Tien-Ping Tsao
CLChia-Cheng Lee
Chia-Cheng Lee
JCJiann-Torng Chen
Jiann-Torng Chen
CHIN LINCHIN LIN
CHIN LIN
Although digoxin is important in heart rate control, the utilization of digoxin is declining due to its narrow therapeutic window. Misdiagnosis or delayed diagnosis of digoxin toxicity is common due to the lack of awareness and the time-consuming laboratory work that is involved. Electrocardiography (ECG) may be able to detect potential digoxin toxicity based on characteristic presentations. Our study attempted to develop a deep learning model to detect digoxin toxicity based on ECG manifestations. This study included 61 ECGs from patients with digoxin toxicity and 177,066 ECGs from patients in the emergency room from November 2011 to February 2019. The deep learning algorithm was trained using approximately 80% of ECGs. The other 20% of ECGs were used to validate the performance of the Artificial Intelligence (AI) system and to conduct a human-machine competition. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were used to evaluate the performance of ECG interpretation between humans and our deep learning system. The AUCs of our deep learning system for identifying digoxin toxicity were 0.912 and 0.929 in the validation cohort and the human-machine competition, respectively, which reached 84.6% of sensitivity and 94.6% of specificity. Interestingly, the deep learning system using only lead I (AUC = 0.960) was not worse than using complete 12 leads (0.912). Stratified analysis showed that our deep learning system was more applicable to patients with heart failure (HF) and without atrial fibrillation (AF) than those without HF and with AF. Our ECG-based deep learning system provides a high-accuracy, economical, rapid, and accessible way to detect digoxin toxicity, which can be applied as a promising decision supportive system for diagnosing digoxin toxicity in clinical practice.

7 January 2022 in Biological Trace Element Research
Verified
Journal Article
Closed access
PDF file
YNYi Jing Ngu
Yi Jing Ngu
ASAnatoly Skalny
Anatoly Skalny
TATinkov Alexey
Tinkov Alexey
CTChien-Sung Tsai
Chien-Sung Tsai
CCChun-Chao Chang
Chun-Chao Chang
JCJung-Su Chang
Jung-Su Chang

1 March 2016 in Heart & Lung
Verified
Journal Article
Closed access
Kang-Hua ChenKang-Hua Chen
Kang-Hua Chen
FTFeng-Chun Tsai
Feng-Chun Tsai
CTChien-Sung Tsai
Chien-Sung Tsai
SYShu-Ling Yeh
Shu-Ling Yeh
LWLi-Chueh Weng
Li-Chueh Weng
LYLi-Chyun Yeh
Li-Chyun Yeh