18 April 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TJTack-Hyun Jung
Tack-Hyun Jung
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
CKChul-Hwan Kim
Chul-Hwan Kim
JHJoon Han
Joon Han
YOYun-Sik Oh
Yun-Sik Oh
CNChul-Ho Noh
Chul-Ho Noh
Owing to the development of highly efficient electric power converters, the number of studies on the construction of low-voltage dc (LVDC) systems is gradually increasing. To use LVDC distribution systems, voltage regulation methods to compensate for the voltage drop and to limit the voltage unbalance are essential. In a bipolar LVDC distribution system, a voltage drop and voltage unbalance could occur because of the load current and the variation in the amount of power supplied to the poles. However, not enough research has been conducted on voltage regulation methods for LVDC distribution systems. To reduce the voltage drop and the voltage unbalance, this paper proposes a voltage regulation method based on the neutral to line drop compensation (NLDC) method, which employs a modified LDC to calculate the sending-end reference voltage. In the NLDC method, the neutral current and neutral line impedance are taken into consideration to compensate for the neutral line potential fluctuation and voltage drop on the pole. The next sending-end voltage is determined by checking the voltage unbalance factor, and it is adjusted to maintain it within the allowable voltage unbalance factor. A voltage regulation algorithm and a bipolar LVDC system model are implemented using the Electromagnetic Transients Program.

11 September 2015 in Resources
Verified
Journal Article
Open access
PDF file
JHJoon Han
Joon Han
YOYun-Sik Oh
Yun-Sik Oh
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
DKDooung Kim
Dooung Kim
CNChul-Ho Noh
Chul-Ho Noh
CKChul-Hwan Kim
Chul-Hwan Kim
It is well known that the Low-Voltage DC (LVDC) distribution system is a promising topology as a future smart distribution system due to its high efficiency and reliability. However, there are still some challenges in the construction and implementation of an LVDC system. For practical application of the LVDC system, therefore, it is necessary to perform any simulation in advance by considering various conditions that can occur in an LVDC system. In order to provide a foundation for analyzing a DC system, this paper presents an LVDC distribution system model including essential components such as power electronic devices, Distributed Energy Resource (DER), and Energy Storage System (ESS), which can be considered for implementation in an LVDC system using Electro-Magnetic Transient Program (EMTP) software. Moreover, an analysis of the characteristic in both the steady state and the transient state is conducted in an LVDC distribution system.

10 February 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
JKJi-Soo Kim
Ji-Soo Kim
CKChul-Hwan Kim
Chul-Hwan Kim
YOYun-Sik Oh
Yun-Sik Oh
GCGyu-Jung Cho
Gyu-Jung Cho
JSJin-Sol Song
Jin-Sol Song

15 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
MKMyongsoo Kim
Myongsoo Kim
JAJae-Guk An
Jae-Guk An
YOYun-Sik Oh
Yun-Sik Oh
SLSeong-Il Lim
Seong-Il Lim
DKDong-Hee Kwak
Dong-Hee Kwak
JSJin-Uk Song
Jin-Uk Song
A fault section in Korean distribution networks is generally determined as a section between a switch with a fault indicator (FI) and a switch without an FI. However, the existing method cannot be applied to distribution networks with distributed generations (DGs) due to false FIs that are generated by fault currents flowing from the load side of a fault location. To identify the false FIs and make the existing method applicable, this paper proposes a method to determine the fault section by utilizing an artificial neural network (ANN) model for validating FIs, which is difficult to determine using mathematical equations. The proposed ANN model is built by training the relationship between the measured A, B, C, and N phase fault currents acquired by numerous simulations on a sample distribution system, and guarantees 100% FI validations for the test data. The proposed method can accurately distinguish genuine and false Fis by utilizing the ability of the ANN model, thereby enabling the conventional FI-based method to be applied to DG-connected distribution networks without any changes to the equipment and communication infrastructure. To verify the performance of the proposed method, various case studies considering real fault conditions are conducted under a Korean distribution network using MATLAB.

28 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BQBangjie Qiu
Bangjie Qiu
JAJae-Guk An
Jae-Guk An
JSJin-Uk Song
Jin-Uk Song
YOYun-Sik Oh
Yun-Sik Oh
An islanding operation of distributed generations (DGs) in emergencies due to a fault in distribution systems can be a means of power supply for important loads in outage areas by facilitating the self-sufficient capability of DGs forming microgrids. This paper presents an optimization-based intentional islanding scheme to derive a near-optimal service restoration (SR) plan. The anti-parallel operation of DGs is considered a new constraint that avoids more than two DGs in an island thereby, enabling simpler control and operation of the distribution system in an emergency. Each island is created by an island partitioning scheme based on the tree representation of the network and fast searching scheme for the tree structure considering load importance, and a genetic algorithm (GA) is utilized to explore possible SR solutions. Case studies on IEEE 69-bus distribution system according to various fault locations are conducted, and the simulation results show that the proposed scheme can restore more loads with higher priority in outage areas by the intentional islanding of DGs. Furthermore, the time for deriving the optimal solution can be reduced since the evaluations for infeasible solutions are not performed.

3 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
GCGyu-Jung Cho
Gyu-Jung Cho
JPJi-Kyung Park
Ji-Kyung Park
SSSeungHyun Sohn
SeungHyun Sohn
SCSe-Jin Chung
Se-Jin Chung
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
CKChul-Hwan Kim
Chul-Hwan Kim
High-speed auto-reclosing is used in power system protection schemes to ensure the stability and reliability of the transmission system; leader-follower auto-reclosing is one scheme type that is widely used. However, when a leader-follower reclosing scheme responds to a permanent fault that affects a transmission line in the proximity of a generation plant, the reclosing directly impacts the turbine-generator shaft; furthermore, the nature of this impact is dependent upon the selection of the leader reclosing terminal. We therefore analyzed the transient torque of the turbine-generator shaft according to the selection of the leader-follower reclosing end between both ends of the transmission line. We used this analysis to propose an adaptive leader-end reclosing algorithm that removes the stress potential of the transient torque to prevent it from damaging the turbine-generator shaft. We conducted a simulation in actual Korean power systems based on the ElectroMagnetic Transients Program (EMTP) and the Dynamic Link Library (DLL) function in EMTP-RV (Restructured Version) to realize the proposed algorithm.