The pore forming properties of synthetic cecropin-melittin hybrid peptide (Acetyl-KWKLFKKIGAVLKVL-CONH2; CM15) were investigated by using photoreceptor rod outer segments (OS) isolated from frog retinae obtained by using the whole-cell configuration of the patch-clamp technique. CM15 was applied (and removed) to (from) the OS in ~50 ms with a computer-controlled microperfusion system. Once the main OS endogenous conductance was blocked with light, the OS membrane resistance was ≥1 GΩ, allowing high resolution, low-noise recordings. Different to alamethicines, CM15 produced voltage-independent membrane permeabilisation, repetitive peptide application caused a progressive permeabilisation increase, and no single-channel events were detected at low peptide concentrations. Collectively, these results indicate a toroidal mechanism of pore formation by CM15.
A mathematical model of the vertebrate phototransduction mechanism was designed in a modular fashion, in that increasingly complex behaviors can be turned on and off to evaluate the relative involvement of all elements of the phototransduction cascade. The problem was approached by starting with a minimum model in which the intracellular cGMP concentration ([cGMP]i) was determined by guanylate cyclase (GC), whose activity was assumed not to be regulated by any factor (such as Ca2+) and by phosphodiesterase (PDE), whose activity was assumed to be proportional to the light intensity. All dependences were subsequently introduced, i.e. the equations describing PDE activation in detail, the Ca2+ regulation of GC and the action of intracellular Ca2+ buffers. The simulations and fits show that a high-gain, smooth time- and light-dependent PDE activation, a Ca2+-dependent GC, and a Ca2+-dependent buffer mechanism are required to account for the flash response kinetics in the dark and on dim backgrounds of light, and the effect of exogenous Ca2+ buffers to produce responses characterized by slow and damped oscillations and to enhance the low-frequency noise. However, it was not possible to find any set of parameters able to simultaneously interpolate the waveform of the flash responses (in the dark and on a background of light) and the responses to steps of light. It is therefore concluded that at least one more shut-off mechanism (possibly not Ca-dependent) is necessary to fully account for the phenomenology of the light response in rod photoreceptors.
Humidity is a well-known interference factor in metal oxide (MOX) gas sensors, significantly impacting their performance in various applications such as environmental monitoring and medical diagnostics. This study investigates the effects of adsorbed water on MOX conductivity using two different materials: pure tin oxide (SnO2) and a tin–titanium–niobium oxide mixture (SnTiNb)xO2 (STN). The results reveal that (SnTiNb)xO2 sensors exhibit reduced sensitivity to humidity compared to pure tin oxide, rendering them more suitable for applications where humidity presence is critical. We aimed to shed light on a still controversial debate over the mechanisms involved in the water surface interactions for the aforementioned materials also by exploring theoretical studies in the literature. Experimental analysis involves varying temperatures (100 to 800 °C) to understand the kinetics of surface reactions. Additionally, a brief high-temperature heating method is demonstrated to effectively remove adsorbed humidity from sensor surfaces. The study employs Arrhenius-like plots for graphical interpretation, providing insights into various water adsorption/desorption phenomena. Overall, this research contributes to a deeper understanding of the role of humidity in MOX gas sensor mechanisms and offers practical insights for sensor design and optimization.
The necessity of detecting and recognizing gases is crucial in many research and application fields, boosting, in the last years, their continuously evolving technology. The basic detection principle of gas sensors relies on the conversion of gas concentration changes into a readable signal that can be analyzed to calibrate sensors to detect specific gases or mixtures. The large variety of gas sensor types is here examined in detail, along with an accurate description of their fundamental characteristics and functioning principles, classified based on their working mechanisms (electrochemical, resonant, optical, chemoresistive, capacitive, and catalytic). This review is particularly focused on chemoresistive sensors, whose electrical resistance changes because of chemical reactions between the gas and the sensor surface, and, in particular, we focus on the ones developed by us and their applications in the medical field as an example of the technological transfer of this technology to medicine. Nowadays, chemoresistive sensors are, in fact, strong candidates for the implementation of devices for the screening and monitoring of tumors (the second worldwide cause of death, with ~9 million deaths) and other pathologies, with promising future perspectives that are briefly discussed as well.