Hongwei Bran Li

Mr. Hongwei Bran Li


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2022 in Medical Image Analysis
Verified
Journal Article
Open access
PBPatrick Bilic
Patrick Bilic
PCPatrick Christ
Patrick Christ
HLHongwei Bran Li
Hongwei Bran Li
EVEugene Vorontsov
Eugene Vorontsov
ABAvi Ben-Cohen
Avi Ben-Cohen
BMBjoern Menze
Bjoern Menze
In this work, we report the set-up and results of the Liver Tumor Segmentation Benchmark (LiTS), which was organized in conjunction with the IEEE International Symposium on Biomedical Imaging (ISBI) 2017 and the International Conferences on Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2017 and 2018. The image dataset is diverse and contains primary and secondary tumors with varied sizes and appearances with various lesion-to-background levels (hyper-/hypo-dense), created in collaboration with seven hospitals and research institutions. Seventy-five submitted liver and liver tumor segmentation algorithms were trained on a set of 131 computed tomography (CT) volumes and were tested on 70 unseen test images acquired from different patients. We found that not a single algorithm performed best for both liver and liver tumors in the three events. The best liver segmentation algorithm achieved a Dice score of 0.963, whereas, for tumor segmentation, the best algorithms achieved Dices scores of 0.674 (ISBI 2017), 0.702 (MICCAI 2017), and 0.739 (MICCAI 2018). Retrospectively, we performed additional analysis on liver tumor detection and revealed that not all top-performing segmentation algorithms worked well for tumor detection. The best liver tumor detection method achieved a lesion-wise recall of 0.458 (ISBI 2017), 0.515 (MICCAI 2017), and 0.554 (MICCAI 2018), indicating the need for further research. LiTS remains an active benchmark and resource for research, e.g., contributing the liver-related segmentation tasks in http://medicaldecathlon.com/. In addition, both data and online evaluation are accessible via https://competitions.codalab.org/competitions/17094.

17 June 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
VCVíctor Manuel Campello
Víctor Manuel Campello
PGPolyxeni Gkontra
Polyxeni Gkontra
CICristian Izquierdo
Cristian Izquierdo
CMCarlos Martin-Isla
Carlos Martin-Isla
ASAlireza Sojoudi
Alireza Sojoudi
KLKarim Lekadir
Karim Lekadir
The emergence of deep learning has considerably advanced the state-of-the-art in cardiac magnetic resonance (CMR) segmentation. Many techniques have been proposed over the last few years, bringing the accuracy of automated segmentation close to human performance. However, these models have been all too often trained and validated using cardiac imaging samples from single clinical centres or homogeneous imaging protocols. This has prevented the development and validation of models that are generalizable across different clinical centres, imaging conditions or scanner vendors. To promote further research and scientific benchmarking in the field of generalizable deep learning for cardiac segmentation, this paper presents the results of the Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation (M&Ms) Challenge, which was recently organized as part of the MICCAI 2020 Conference. A total of 14 teams submitted different solutions to the problem, combining various baseline models, data augmentation strategies, and domain adaptation techniques. The obtained results indicate the importance of intensity-driven data augmentation, as well as the need for further research to improve generalizability towards unseen scanner vendors or new imaging protocols. Furthermore, we present a new resource of 375 heterogeneous CMR datasets acquired by using four different scanner vendors in six hospitals and three different countries (Spain, Canada and Germany), which we provide as open-access for the community to enable future research in the field.

19 March 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HKHugo J. Kuijf
Hugo J. Kuijf
ACAdria Casamitjana
Adria Casamitjana
DCD. Louis Collins
D. Louis Collins
MDMahsa Dadar
Mahsa Dadar
AGAchilleas Georgiou
Achilleas Georgiou
MCM. Jorge Cardoso
M. Jorge Cardoso
Quantification of cerebral white matter hyperintensities (WMH) of presumed vascular origin is of key importance in many neurological research studies. Currently, measurements are often still obtained from manual segmentations on brain MR images, which is a laborious procedure. The automatic WMH segmentation methods exist, but a standardized comparison of the performance of such methods is lacking. We organized a scientific challenge, in which developers could evaluate their methods on a standardized multi-center/-scanner image dataset, giving an objective comparison: the WMH Segmentation Challenge. Sixty T1 + FLAIR images from three MR scanners were released with the manual WMH segmentations for training. A test set of 110 images from five MR scanners was used for evaluation. The segmentation methods had to be containerized and submitted to the challenge organizers. Five evaluation metrics were used to rank the methods: 1) Dice similarity coefficient; 2) modified Hausdorff distance (95th percentile); 3) absolute log-transformed volume difference; 4) sensitivity for detecting individual lesions; and 5) F1-score for individual lesions. In addition, the methods were ranked on their inter-scanner robustness; 20 participants submitted their methods for evaluation. This paper provides a detailed analysis of the results. In brief, there is a cluster of four methods that rank significantly better than the other methods, with one clear winner. The inter-scanner robustness ranking shows that not all the methods generalize to unseen scanners. The challenge remains open for future submissions and provides a public platform for method evaluation.

1 December 2018 in NeuroImage
Verified
Journal Article
Open access
HLHongwei Bran Li
Hongwei Bran Li
GJGongfa Jiang
Gongfa Jiang
JZJianguo Zhang
Jianguo Zhang
RWRuixuan Wang
Ruixuan Wang
ZWZhaolei Wang
Zhaolei Wang
BMBjoern Menze
Bjoern Menze
White matter hyperintensities (WMH) are commonly found in the brains of healthy elderly individuals and have been associated with various neurological and geriatric disorders. In this paper, we present a study using deep fully convolutional network and ensemble models to automatically detect such WMH using fluid attenuation inversion recovery (FLAIR) and T1 magnetic resonance (MR) scans. The algorithm was evaluated and ranked 1st in the WMH Segmentation Challenge at MICCAI 2017. In the evaluation stage, the implementation of the algorithm was submitted to the challenge organizers, who then independently tested it on a hidden set of 110 cases from 5 scanners. Averaged dice score, precision and robust Hausdorff distance obtained on held-out test datasets were 80%, 84% and 6.30 mm respectively. These were the highest achieved in the challenge, suggesting the proposed method is the state-of-the-art. Detailed descriptions and quantitative analysis on key components of the system were provided. Furthermore, a study of cross-scanner evaluation is presented to discuss how the combination of modalities affect the generalization capability of the system. The adaptability of the system to different scanners and protocols is also investigated. A quantitative study is further presented to show the effect of ensemble size and the effectiveness of the ensemble model. Additionally, software and models of our method are made publicly available. The effectiveness and generalization capability of the proposed system show its potential for real-world clinical practice.

9 January 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YZYu Zhao
Yu Zhao
HLHongwei Bran Li
Hongwei Bran Li
Shaohua WanShaohua Wan
Shaohua Wan
ASAnjany Sekuboyina
Anjany Sekuboyina
XHXiaobin Hu
Xiaobin Hu
BMBjoern Menze
Bjoern Menze
Accurate and automatic organ segmentation is critical for computer-aided analysis towards clinical decision support and treatment planning. State-of-the-art approaches have achieved remarkable segmentation accuracy on large organs, such as the liver and kidneys. However, most of these methods do not perform well on small organs, such as the pancreas, gallbladder, and adrenal glands, especially when lacking sufficient training data. This paper presents an automatic approach for small organ segmentation with limited training data using two cascaded steps-localization and segmentation. The localization stage involves the extraction of the region of interest after the registration of images to a common template and during the segmentation stage, a voxel-wise label map of the extracted region of interest is obtained and then transformed back to the original space. In the localization step, we propose to utilize a graph-based groupwise image registration method to build the template for registration so as to minimize the potential bias and avoid getting a fuzzy template. More importantly, a novel knowledge-aided convolutional neural network is proposed to improve segmentation accuracy in the second stage. This proposed network is flexible and can combine the effort of both deep learning and traditional methods, consequently achieving better segmentation relative to either of individual methods. The ISBI 2015 VISCERAL challenge dataset is used to evaluate the presented approach. Experimental results demonstrate that the proposed method outperforms cutting-edge deep learning approaches, traditional forest-based approaches, and multi-atlas approaches in the segmentation of small organs.

9 July 2022 in Medical Image Analysis
Verified
Journal Article
Closed access
Xiahai ZhuangXiahai Zhuang
Xiahai Zhuang
JXJiahang Xu
Jiahang Xu
Xinzhe LuoXinzhe Luo
Xinzhe Luo
CCChen Chen
Chen Chen
COCheng Ouyang
Cheng Ouyang
LLLei Li
Lei Li