Fabian Schiedat

Dr. Fabian Schiedat

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2016 in Cardiology Journal
Verified
Journal Article
Open access
AKAxel Kloppe
Axel Kloppe
DMDejan Mijic
Dejan Mijic
FSFabian Schiedat
Fabian Schiedat
HBHarilaos Bogossian
Harilaos Bogossian
AMAndreas Mügge
Andreas Mügge
BLBernd Lemke
Bernd Lemke
Cardiac contractility modulation (CCM) signals are non-excitatory electrical signals delivered during the absolute refractory period intended to improve contraction and cardiac function. Clinical trials have shown that CCM treatment significantly improves exercise tolerance and quality of life in symptomatic heart failure patients. Studies with CCM therapy typically include CCM delivery for 3, 5 or 7 h per day, although other configurations are also commonly used. Each has been associated with improved outcomes in heart failure, but it is not clear whether different application durations are associated with the various degrees of benefit. The purpose of the current pilot evaluation study was to evaluate the quality of life, exercise tolerance, and cardiac function, over a 6-month period when CCM was delivered for 5 h/day vs. 12 h/day. Increasing the daily CCM therapy duration is safe and as good as the standard CCM periods of application per day. This single center pilot evaluation study involved 19 medically refractory symptomatic patients with heart failure and reduced left ventricular function who underwent implantation of an Optimizer™ system (Impulse Dynamics, Orangeburg, NY, USA). Patients were randomized into one of two treatment groups; 5 h/day CCM treatment or 12 h/day CCM treatment. Subjects and evaluating physicians were blinded to the study group. Subjects returned to the hospital after 12 and 24 weeks. Efficacy evaluations included changes from baseline to 24 weeks in Minnesota Living With Heart Failure Questionnaire score (MLWHFQ), maximal oxygen consumption in the cardio-pulmonary stress test (peak VO2), New York Heart Association classification (NYHA), 6-min walk distance (6MWD), and ejection fraction (EF). At the end of 24 weeks, clinical improvement was observed in the entire cohort in all efficacy measures (mean change from baseline of -17.1 in MLWHFQ, -0.86 in NYHA, and improvement trend of 1.48 mL O2/kg/min in peak VO2, 31.3 m in 6MWD, and 2.25% in EF). There were no significant differences, either clinically or statistically, between the groups receiving CCM for 5 h/day vs. 12 h/day. Three subjects were voluntarily withdrawn before completing the study. One subject died from pneumonia after 125 days, and 6 serious adverse events were reported, none of which was classified as related to either the device or the procedure. Together with previously reported experience with CCM, delivery of CCM therapy is equally safe and appears similarly effective over the range of shorter (5 h) to longer (12 h) daily periods of application. Given the small sample size, further studies are warranted.

31 May 2019 in Clinical Research in Cardiology
Verified
Journal Article
Closed access
PDF file
FSFabian Schiedat
Fabian Schiedat
DSDominik Schöne
Dominik Schöne
AAAssem Aweimer
Assem Aweimer
LBLeif Bösche
Leif Bösche
AEAydan Ewers
Aydan Ewers
AKAxel Kloppe
Axel Kloppe

12 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DKDario Knorr
Dario Knorr
Dirk BandorskiDirk Bandorski
Dirk Bandorski
HBHarilaos Bogossian
Harilaos Bogossian
KIKonstantinos Iliodromitis
Konstantinos Iliodromitis
FSFabian Schiedat
Fabian Schiedat
SBSpiridon Botsios
Spiridon Botsios
Background: Cephalic vein cutdown (CVC) and subclavian vein puncture (SVP) are the most commonly used access sites for transvenous lead placement of cardiac implantable electronic devices (CIEDs). Limited knowledge exists about the long-term patency of the vascular lumen housing the leads. Methods: Among the 2703 patients who underwent CIED procedures between 2005 and 2013, we evaluated the phlebographies of 162 patients scheduled for an elective CIED replacement (median of 6.4 years after the first operation). The phlebographies were divided into four stenosis types: Type I = 0%, Type II = 1–69%, Type III = 70–99%, and Type IV = occlusion. Due to the fact that no standardized stenosis categorization exists, experienced physicians in consensus with the involved team made the applied distribution. The primary endpoint was the occurrence of stenosis Type III or IV in the CVC group and in the SVP group. Results: In total, 162 patients with venography were enrolled in this study. The prevalence of high-degree stenosis was significantly lower in the CVC group (7/89, 7.8%) than in the SVP group (15/73, 20.5%, p = 0.023). In the CVC group, venographies showed a lower median stenosis (33%) than in the SVP group (median 42%). Conclusions: The present study showed that the long-term patency of the subclavian vein is higher after CVC than after SVP for venous access in patients with CIED.

10 April 2024 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
FSFabian Schiedat
Fabian Schiedat
BMBenjamin Meuterodt
Benjamin Meuterodt
MPMagnus Prull
Magnus Prull
AAAssem Aweimer
Assem Aweimer
MGMichael Gotzmann
Michael Gotzmann
AKAxel Kloppe
Axel Kloppe
Background: Patients with progressive chronic kidney disease (CKD) are at higher risk of infections and complications from cardiac implantable electronic devices (CIED). In patients with a primary or secondary prophylactic indication, implantable cardiac defibrillators (ICD) can prevent sudden cardiac deaths (SCD). We retrospectively compared transvenous-ICD (TV-ICD) and intermuscularly implanted subcutaneous-ICD (S-ICD) associated infections and complication rates together with hospitalizations in recipients with stage 4 kidney disease.Methods: We retrospectively analyzed 70 patients from six German centers with stage 4 CKD who received either a prophylactic TV-ICD with a single right ventricular lead, 49 patients, or a S-ICD, 21 patients. Follow-Ups (FU) were performed bi-annually.Results: The TV-ICD patients were significantly older. This group had more patients with a history of atrial arrhythmias and more were prescribed anti-arrhythmic medication compared with the S-ICD group. There were no significant differences for other baseline characteristics. The median and interquartile range of FU durations were 55.2 (57.6–69.3) months. During FU, patients with a TV-ICD system experienced significantly more device associated infections (n = 8, 16.3% vs. n = 0; p < 0.05), device-associated complications (n = 13, 26.5% vs. n = 1, 4.8%; p < 0.05) and device associated hospitalizations (n = 10, 20.4% vs. n = 1, 4.8%; p < 0.05).Conclusion: In this long-term FU of patients with stage 4 CKD and an indication for a prophylactic ICD, the S-ICD was associated with significantly fewer device associated infections, complications and hospitalizations compared with TV-ICDs.

22 February 2024 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
AKAxel Kloppe
Axel Kloppe
JWJoachim Winter
Joachim Winter
MPMagnus Prull
Magnus Prull
AAAssem Aweimer
Assem Aweimer
IEIbrahim El-Battrawy
Ibrahim El-Battrawy
FSFabian Schiedat
Fabian Schiedat

29 September 2021 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Open access
PDF file
FSFabian Schiedat
Fabian Schiedat
DMDejan Mijic
Dejan Mijic
ZKZana Karosiene
Zana Karosiene
HBHarilaos Bogossian
Harilaos Bogossian
MZMarkus Zarse
Markus Zarse
AKAxel Kloppe
Axel Kloppe
Background: Optimization of cardiac resynchronization therapy (CRT) is often time‐consuming and therefore underused in a clinical setting. Novel device‐based algorithms aiming to simplify optimization include a dynamic atrioventricular delay (AVD) algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott). This study examines the acute effect of SyncAV and MPP on electrical synchrony in patients with newly and chronically implanted CRT devices.Methods: Patients with SyncAV and MPP enabled devices were prospectively enrolled during implant or scheduled follow‐up. Blinded 12‐lead electrocardiographic acute measurements of QRS duration (QRSd) were performed for intrinsic QRSd (Intrinsic), bi‐ventricular pacing (BiV), MPP, BiV with SyncAV at default offset 50 ms (BiVSyncAVdef), BiV with SyncAV at patient‐specific optimised offset (BiVSyncAVopt), MPP with SyncAV at default offset 50 ms (MPPSyncAVdef), and MPP with SyncAV at patient‐specific optimised offset (MPPSyncAVopt).Results: Thirty‐three patients were enrolled. QRSd for Intrinsic, BiV, MPP, BiVSyncAVdef, BiVSyncAVopt, MPPSyncAVdef, MPPSyncAVopt were 160.4 ± 20.6 ms, 141.0 ± 20.5 ms, 130.2 ± 17.2 ms, 121.7 ± 20.9 ms, 117.0 ± 19.0 ms, 121.2 ± 17.1 ms, 108.7 ± 16.5 ms respectively. MPPSyncAVopt led to greatest reduction of QRSd relative to Intrinsic (−31.6 ± 11.1%; p < .001), showed significantly shorter QRSd compared to all other pacing configurations (p < .001) and shortest QRSd in every patient. Shortening of QRSd was not significantly different between newly and chronically implanted devices (−51.6 ± 14.7 ms vs. −52.7 ± 21.9 ms; p = .99).Conclusion: SyncAV and MPP improved acute electrical synchrony in CRT. Combining both technologies with patient‐specific optimization resulted in greatest improvement, regardless of time since implantation.Whats newNovel device‐based algorithms like a dynamic AVD algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott) aim to simplify CRT optimization. Our data show that a combination of patient tailored SyncAV optimization and MPP results in greatest improvement of electrical synchrony in CRT measured by QRS duration, regardless if programmed in newly or chronically implanted devices. This is the first study to our knowledge to examine a combination of these device‐based algorithms. The results help understanding the ideal ventricular excitation in heart failure.