Naveen Chandrashekar

Dr. Naveen Chandrashekar


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2016 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
RBRyan Bakker
Ryan Bakker
STSebastian Tomescu
Sebastian Tomescu
EBElora Brenneman
Elora Brenneman
GHGajendra Hangalur
Gajendra Hangalur
ALAndrew Laing
Andrew Laing
NCNaveen Chandrashekar
Naveen Chandrashekar
The relationships between non‐contact anterior cruciate ligament injuries and the underlying biomechanics are still unclear, despite large quantities of academic research. The purpose of this research was to study anterior cruciate ligament strain during jump landing by investigating its correlation with sagittal plane kinetic/kinematic parameters and by creating an empirical model to estimate the maximum strain. Whole‐body kinematics and ground reaction forces were measured from seven subjects performing single leg jump landing and were used to drive a musculoskeletal model that estimated lower limb muscle forces. These muscle forces and kinematics were then applied on five instrumented cadaver knees using a dynamic knee simulator system. Correlation analysis revealed that higher ground reaction force, lower hip flexion angle and higher hip extension moment among others were correlated with higher peak strain (p < 0.05). Multivariate regression analyses revealed that intrinsic anatomic factors account for most of the variance in strain. Among the extrinsic variables, hip and trunk flexion angles significantly contributed to the strain. The empirical relationship developed in this study could be used to predict the relative strain between jumps of a participant and may be beneficial in developing training programs designed to reduce an athlete's risk of injury. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1636–1644, 2016.

1 June 2016 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
GHGajendra Hangalur
Gajendra Hangalur
EBElora Brenneman
Elora Brenneman
MNMicah Nicholls
Micah Nicholls
RBRyan Bakker
Ryan Bakker
ALAndrew Laing
Andrew Laing
NCNaveen Chandrashekar
Naveen Chandrashekar
It is unknown whether prophylactic knee braces can reduce the strain in the anterior cruciate ligament during dynamic activities. An athlete, who had characteristics of high anterior cruciate ligament injury risk, was chosen. A motion capture system (Optotrak Certus; Northern Digital, Waterloo, ON, Canada) was used to record dynamic trials during drop-landing activity of this subject with and without the knee brace being worn. A musculoskeletal model was used to estimate the muscle forces during this activity. A dynamic knee simulator then applied kinematics and muscle forces on a cadaver knee with and without the brace mounted on it. The anterior cruciate ligament strain was measured. The peak strain in the anterior cruciate ligament was substantially lower for the braced (7%) versus unbraced (20%) conditions. Functional knee braces could decrease the strain in the anterior cruciate ligament during dynamic activities in a high-risk subject. However, the reduction seems to be a result of altered muscle firing pattern due to the brace. Prophylactic knee brace could reduce the strain in the anterior cruciate ligament of high-risk subjects during drop-landing through altered muscle firing pattern associated with brace wear. This could help reduce the anterior cruciate ligament injury risk.

1 January 2012 in The Knee
Verified
Journal Article
Closed access
NCNaveen Chandrashekar
Naveen Chandrashekar
JSJames Slauterbeck
James Slauterbeck
JHJavad Hashemi
Javad Hashemi

1 September 2009 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
DBDavid Bishop
David Bishop
AMAllan Moore
Allan Moore
NCNaveen Chandrashekar
Naveen Chandrashekar
Traumatic knee injuries in automobile accidents and sports often lead to damage of the peroneal nerve. A lack of control of muscles innervated by the peroneal nerve due to this damage, results in the inability to dorsiflex and evert the foot and to extend the toes. This condition is commonly known as foot drop. Foot drop reduces the stability in the body while walking and running and may also cause injury due to lack of foot clearance during the swing phase of the gait. Traditionally, an ankle foot orthosis (AFO), comprised of a moulded sheet of plastic that conforms around the posterior calf and distally contains all or part of the calcaneous as well as the plantar foot, is used to treat foot drop. The intent of this orthosis is to dorsiflex the foot to provide clearance during the swing phase of walking and running. Traditional AFO results in increased pressures due to a decrease in dorsiflexion range of motion at the ankle and make the orthosis increasingly uncomfortable to wear. Several other existing designs of foot drop AFO suffer from similar inadequacies. To address these issues, a new AFO was developed. The device was successfully used by one person with foot drop without issues for more than one year. This new design conforms to the lower anterior shin and dorsum of the foot using dorsiassist Tamarack ankle joints to allow for greater plantar and dorsiflexion range of motion. While still limiting ankle inversion it does allow for more ankle eversion. This orthosis can be discretely worn inside shoes due to its smaller size, and can be worn for a longer period of time without discomfort.

23 October 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JBJeffrey B. Barker
Jeffrey B. Barker
DCDuane S. Cronin
Duane S. Cronin
NCNaveen Chandrashekar
Naveen Chandrashekar
Numerical finite element (FE) models of the neck have been developed to simulate occupant response and predict injury during motor vehicle collisions. However, there is a paucity of data on the response of young cervical spine segments under dynamic loading in flexion and extension, which is essential for the development or validation of tissue-level FE models. This limitation was identified during the development and validation of the FE model used in this study. The purpose of this study was to measure the high rotation rate loading response of human cervical spine segments in flexion and extension, and to investigate a new tissue-level FE model of the cervical spine with the experimental data to address a limitation in available data. Four test samples at each segment level from C2–C3 to C7–T1 were dissected from eight donors and were tested to 10 deg of rotation at 1 and 500 deg/s in flexion and extension using a custom built test apparatus. There was strong evidence (p < 0.05) of increased stiffness at the higher rotation rate above 4 deg of rotation in flexion and at 8 deg and 10 deg of rotation in extension. Cross-correlation software, Cora, was used to evaluate the fit between the experimental data and model predictions. The average rating was 0.771, which is considered to demonstrate a good correlation to the experimental data.

11 February 2013 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
KCKarla Cassidy
Karla Cassidy
GHGajendra Hangalur
Gajendra Hangalur
PSPreet Sabharwal
Preet Sabharwal
NCNaveen Chandrashekar
Naveen Chandrashekar
The mechanism of noncontact anterior cruciate ligament (ACL) injury is not well understood. It is partly because previous studies have been unable to relate dynamic knee muscle forces during sports activities such as landing from a jump to the strain in the ACL. We present a combined in vivo/in vitro method to relate the muscle group forces to ACL strain during jump-landing using a newly developed dynamic knee simulator. A dynamic knee simulator system was designed and developed to study the sagittal plane biomechanics of the knee. The simulator is computer controlled and uses six powerful electromechanical actuators to move a cadaver knee in the sagittal plane and to apply dynamic muscle forces at the insertion sites of the quadriceps, hamstring, and gastrocnemius muscle groups and the net moment at the hip joint. In order to demonstrate the capability of the simulator to simulate dynamic sports activities on cadaver knees, motion capture of a live subject landing from a jump on a force plate was performed. The kinematics and ground reaction force data obtained from the motion capture were input into a computer based musculoskeletal lower extremity model. From the model, the force-time profile of each muscle group across the knee during the movement was extracted, along with the motion profiles of the hip and ankle joints. This data was then programmed into the dynamic knee simulator system. Jump-landing was simulated on a cadaver knee successfully. Resulting strain in the ACL was measured using a differential variable reluctance transducer (DVRT). Our results show that the simulator has the capability to accurately simulate the dynamic sagittal plane motion and the dynamic muscle forces during jump-landing. The simulator has high repeatability. The ACL strain values agreed with the values reported in the literature. This combined in vivo/in vitro approach using this dynamic knee simulator system can be effectively used to study the relationship between sagittal plane muscle forces and ACL strain during dynamic activities.