Kun Wang

Dr. Kun Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KWKun Wang
Kun Wang
XWXiaodong Wang
Xiaodong Wang
SZShaoqiang Zheng
Shaoqiang Zheng
CLCheng Li
Cheng Li
LJLiang Jin
Liang Jin
MLming Li
ming Li
We aimed to compare dedicated coronary computed tomography angiography (CCTA) followed by high-pitch scanning and triple-rule-out computed tomography angiography (TRO-CTA) in terms of radiation dose, contrast media (CM) use, and image quality. Patients with acute chest pain were retrospectively enrolled and assigned to group A (n = 55; scanned with dedicated CCTA followed by high-pitch scanning) or group B (n = 45; with TRO-CTA). Patient characteristics, radiation dose, CM use, and quantitative parameters (CT value, image noise, signal-to-noise ratio, contrast-to-noise ratio, and image quality score) of pulmonary arteries (PAs), thoracic aortae (TAs), and coronary arteries (CAs) were compared. The total effective dose was significantly lower in group A (6.25 ± 2.94 mSv) than B (8.93 ± 4.08 mSv; p < 0.001). CM volume was significantly lower in group A (75.7 ± 8.9 mL) than B (95.0 ± 0 mL; p < 0.001). PA and TA image quality were significantly better in group B, whereas that of CA was significantly better in group A. Qualitative image scores of PA and TA scans rated by radiologists were similar, whereas that of CA scans was significantly higher in group A than B (p < 0.001). Dedicated CCTA followed by high-pitch scanning demonstrated lower radiation doses and CM volume without debasing qualities of PA, TA, and CA scans than did TRO-CTA.

23 January 2023 in Journal of Thoracic Imaging
Verified
Journal Article
Open access
LJLiang Jin
Liang Jin
KWKun Wang
Kun Wang
XWXiaodong Wang
Xiaodong Wang
CLCheng Li
Cheng Li
YSYingli Sun
Yingli Sun
MLming Li
ming Li
Purpose: Shortened injection durations are not recommended in step-and-shoot coronary computed tomography angiography (CCTA). We aimed to evaluate the image quality of CCTA performed using bodyweight-adjusted iodinated contrast media (ICM) with different injection durations to generate an optimized ICM administration protocol to acquire convincible image quality in step-and-shoot CCTA. Materials and Methods: A total of 200 consecutive patients with suspected coronary artery disease (CAD) were enrolled in group A (N=50, 350 mgI/mL, bodyweight×0.8 mL/kg with a 13-s injection duration), group B (N=50, 350 mgI/mL, bodyweight×0.9 mL/kg with a 13-s injection duration), group C (N=50, 350 mgI/mL, bodyweight×0.8 mL/kg with a 12-s injection duration), and group D (N=50, 320 mgI/mL, bodyweight×0.8 mL/kg with a 13-s injection duration). Patient characteristics, ICM administration protocols, quantitative computed tomography (CT) value measurements, and qualitative image scores were analyzed and compared among the groups. Results: Groups A and D achieved the lowest ICM volume, saline volume, injection flow rate, and total iodine and iodine injection rates among the groups. All the CT values of the coronary arteries in all groups were >300 HU. All the observers’ average scores exceeded three points. In group A, the CT values showed significant positive correlation with the iodine injection rate (r=0.226, P<0.001), whereas the signal-to-noise ratio (r=−0.004, P=0.927) and contrast-to-noise ratio (r=−0.006, P=0.893) values were not. Conclusions: Bodyweight×0.8 mL/kg with a 13-second injection duration is a comprehensive option for step-and-shoot CCTA with improved image quality, and a 350 mgI/mL iodine concentration is preferred.