Pulse signals carry comprehensive information regarding human cardiovascular physiology and pathology, providing a noninvasive and continuous method to assess cardiovascular health status in blood pressure monitoring. The blood pressure measurement method based on the pulse signal needs to extract the features of the single-cycle pulse signal, while the pulse signal pertains to the weak physiological signal of body surface. The acquisition process is susceptible to various factors leading to abnormal cycles, especially adjacent channel interference, affecting the subsequent feature extraction. To address this problem, this paper conducts an analysis of the formation mechanism of adjacent channel interference and proposes a single-cycle pulse signal recognition algorithm based on a one-dimensional deep convolutional neural network (1D-CNN) model. Radial pulse signals were collected from 150 subjects by pulse bracelet, and a dataset comprising 3446 single-cycle signals was extracted in total after denoising, single-cycle segmentation, and standardized preprocessing. The 1D-CNN model is trained to classify input signals into three categories: effective pulse signals, distortion, and interference signals. This classification is achieved by evaluating the waveform morphology of the signals within a single cycle. The results show that the overall classification accuracy of the algorithm on the test set is 98.26%, in which the classification accuracy of pulse waves is 99.8%, indicating that it can effectively recognize single-cycle pulse waves, which lays the foundation for subsequent continuous blood pressure measurement.
Delay multiply and sum beamforming (DMAS) is a non-linear method used in ultrasound imaging which offers superior performance to conventional delay and sum beamforming (DAS). While the combination of DMAS and coherence factor (CF) can further improve single plane-wave imaging lateral resolution, by using CF to weight the DMAS output, the main lobe width and aberration effects can be suppressed, which will improve the disadvantage of low lateral resolution when imaging with a single plane-wave. However, in low signal-to-noise ratio (SNR) environments, the speckle variance of the image increases, and there are black area artifacts around high echo objects. To improve the quality of the scatter without significantly reducing the lateral resolution of the DMAS-CF, this paper proposes an adaptive spatio-temporally smoothed coherence factor (GSTS-CF) combined with delay multiply and sum beamformer (DMAS + GSTS-CF), which uses the generalized coherence factor (GCF) as a local coherence detection tool to adaptively determine the subarray length to obtain an improved adaptive spatio-temporally smoothed factor, and uses this factor to weight the output of DMAS. The simulation and experimental data show that the proposed method improves lateral resolution (20 mm depth) by 86.87% compared to DAS, 52.13% compared to DMAS, 15.84% compared to DMAS + STS-CF, and has a full width at half maxima (FWHM) similar to DMAS-CF. The proposed method improves the speckle signal-to-noise ratio (sSNR) by 87.85% (simulation) and 77.84% (in carotid) compared to DMAS-CF, 20.37% (simulation) and 40.74% (in carotid) compared to DMAS, 15.03% (simulation) and 13.46% (in carotid) compared to DMAS + STS-CF, and has sSNR and scatter variance similar to DAS. This indicates that the method improves scatter quality (lower scatter variance and higher sSNR) without significantly reducing lateral resolution.
19 November 2024 in Journal of Mechanics in Medicine and Biology