Harald Rösner

Dr. Harald Rösner

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Ultramicroscopy
Verified
Journal Article
Closed access
HRHarald Rösner
Harald Rösner
MPMartin Peterlechner
Martin Peterlechner
Christian KübelChristian Kübel
Christian Kübel
VSVitalij Schmidt
Vitalij Schmidt
Gerhard WildeGerhard Wilde
Gerhard Wilde

21 April 2017 in Physical Review B
Verified
Journal Article
Closed access
PDF file
VHVitalij Hieronymus-Schmidt
Vitalij Hieronymus-Schmidt
HRHarald Rösner
Harald Rösner
GWGerhard Wilde
Gerhard Wilde
AZAlessio Zaccone
Alessio Zaccone
Plastic deformation of metallic glasses performed well below the glass transition temperature leads to the formation of shear bands as a result of shear localization. It is believed that shear banding originates from individual stress concentrators having quadrupolar symmetry. To elucidate the underlying mechanisms of shear-band formation, microstructural investigations were carried out on sheared zones using transmission electron microscopy. Here we show evidence of a characteristic signature present in shear bands manifested in the form of sinusoidal density variations. We present an analytical solution for the observed postdeformation state derived from continuum mechanics using an alignment of quadrupolar stress-field perturbations for the plastic events. Since we observe qualitatively similar features for three different types of metallic glasses that span the entire range of characteristic properties of metallic glasses, we conclude that the reported deformation behavior is generic for all metallic glasses, and thus has far-reaching consequences for the deformation behavior of amorphous solids in general.

1 March 2016 in Acta Materialia
Verified
Journal Article
Closed access
YBYulia Buranova
Yulia Buranova
HRHarald Rösner
Harald Rösner
SDSergiy V. Divinskiy
Sergiy V. Divinskiy
RIRobert Imlau
Robert Imlau
Gerhard WildeGerhard Wilde
Gerhard Wilde

1 October 2020 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
FDFarnaz A. Davani
Farnaz A. Davani
SHSven Hilke
Sven Hilke
HRHarald Rösner
Harald Rösner
DGDavid Geissler
David Geissler
AGAnnett Gebert
Annett Gebert
GWGerhard Wilde
Gerhard Wilde

6 July 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
FDFarnaz A. Davani
Farnaz A. Davani
SHSven Hilke
Sven Hilke
HRHarald Rösner
Harald Rösner
DGDavid Geissler
David Geissler
AGAnnett Gebert
Annett Gebert
Gerhard WildeGerhard Wilde
Gerhard Wilde
Understanding ductility or brittleness of monolithic bulk metallic glasses requires detailed knowledge of the amorphous structure. The medium-range order (MRO) of ductile Pd 40 Ni 40 P 20 and brittle Zr 52.5 Cu 17.9 Ni 14.6 Al 10 Ti 5 (Vit105) was characterized prior to and after notched three-point bending tests using variable-resolution fluctuation electron microscopy. Here, we show the presence of a second larger MRO correlation length in the ductile material, which is not present in the brittle material. The second larger correlation length accounts for an increased heterogeneity, which seems to enable an easier shear band formation and thus explain the difference in deformability.

1 May 2007 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
Gerhard WildeGerhard Wilde
Gerhard Wilde
PBPeter Bunzel
Peter Bunzel
HRHarald Rösner
Harald Rösner
JWJörg Weissmüller
Jörg Weissmüller