Frank Feyerabend

Dr. Frank Feyerabend


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2008 in Current Opinion in Solid State and Materials Science
Verified
Journal Article
Closed access
FWFrank Witte
Frank Witte
Norbert HortNorbert Hort
Norbert Hort
CVCarla Vogt
Carla Vogt
SCSmadar Cohen
Smadar Cohen
KKKarl Ulrich Kainer
Karl Ulrich Kainer
FFFrank Feyerabend
Frank Feyerabend

1 May 2007 in Biomaterials
Verified
Journal Article
Closed access
FWFrank Witte
Frank Witte
FFFrank Feyerabend
Frank Feyerabend
PMPetra Maier
Petra Maier
JFJens Fischer
Jens Fischer
MSMichael Störmer
Michael Störmer
Norbert HortNorbert Hort
Norbert Hort

1 May 2010 in Acta Biomaterialia
Verified
Journal Article
Closed access
Norbert HortNorbert Hort
Norbert Hort
YHY Huang
Y Huang
DFD Fechner
D Fechner
MSM Störmer
M Störmer
CBC Blawert
C Blawert
FFFrank Feyerabend
Frank Feyerabend

1 May 2010 in Acta Biomaterialia
Verified
Journal Article
Closed access
FFFrank Feyerabend
Frank Feyerabend
JFJanine Fischer
Janine Fischer
JHJakob Holtz
Jakob Holtz
FWFrank Witte
Frank Witte
RWRegine Willumeit
Regine Willumeit
Norbert HortNorbert Hort
Norbert Hort

1 February 2015 in Acta Biomaterialia
Verified
Journal Article
Closed access
ASAdela Helvia Martinez Sanchez
Adela Helvia Martinez Sanchez
BLBerengere Luthringer
Berengere Luthringer
FFFrank Feyerabend
Frank Feyerabend
RWRegine Willumeit
Regine Willumeit

16 June 2013
Verified
Journal Article
Closed access
DTDi Tie
Di Tie
FFFrank Feyerabend
Frank Feyerabend
WMW-D Müller
W-D Müller
RSR Schade
R Schade
KLK Liefeith
K Liefeith
RWRegine Willumeit
Regine Willumeit
The use of magnesium alloys as degradable metals for biomedical applications is a topic of ongoing research and the demand for multifunctional materials is increasing. Hence, binary Mg-Ag alloys were designed as implant materials to combine the favourable properties of magnesium with the well-known antibacterial property of silver. In this study, three Mg-Ag alloys, Mg2Ag, Mg4Ag and Mg6Ag that contain 1.87 %, 3.82 % and 6.00 % silver by weight, respectively, were cast and processed with solution (T4) and aging (T6) heat treatment. The metallurgical analysis and phase identification showed that all alloys contained Mg4Ag as the dominant β phase. After heat treatment, the mechanical properties of all Mg-Ag alloys were significantly improved and the corrosion rate was also significantly reduced, due to presence of silver. Mg(OH)₂ and MgO present the main magnesium corrosion products, while AgCl was found as the corresponding primary silver corrosion product. Immersion tests, under cell culture conditions, demonstrated that the silver content did not significantly shift the pH and magnesium ion release. In vitro tests, with both primary osteoblasts and cell lines (MG63, RAW 264.7), revealed that Mg-Ag alloys show negligible cytotoxicity and sound cytocompatibility. Antibacterial assays, performed in a dynamic bioreactor system, proved that the alloys reduce the viability of two common pathogenic bacteria, Staphylococcus aureus (DSMZ 20231) and Staphylococcus epidermidis (DSMZ 3269), and the results showed that the killing rate of the alloys against tested bacteria exceeded 90%. In summary, biodegradable Mg-Ag alloys are cytocompatible materials with adjustable mechanical and corrosion properties and show promising antibacterial activity, which indicates their potential as antibacterial biodegradable implant materials.