There are several differential diagnoses of unilateral sinus disease. One of these is inverted papilloma (IP) of the maxillary sinus, which is a common benign tumor with a substantial rate of malignant transformation. In general, endoscopic endonasal techniques for addressing the tumor are favored nowadays instead of classical external approaches. The aim of this retrospective study was to investigate the long-term outcome of inverted papilloma treated endoscopically via the prelacrimal approach. We reviewed 17 patients with primary or recurrent IP of the maxillary sinus that were treated via the prelacrimal endoscopic endonasal technique. After a median follow-up period of 45.9 months (3.8 years), none of the 17 included patients showed signs of recurrent disease and no serious complications were reported. Hypoesthesia of the incisors was reported by four patients and was resolved with time in one. All of the maxillary sinuses could be fully visualized with the flexible endoscope. IP is an important differential diagnosis in the clinical finding of unilateral nasal polypoid lesions. The prelacrimal approach is an effective and safe method in the treatment of IP with limited patient morbidity.
1 September 2012 in American Journal of Otolaryngology
Patients with surgically treated head and neck cancer and clinical N0 neck with high risk of occult lymph node metastasis undergo elective neck dissection (ND). Late lymph node metastasis may appear in those patients with pN0 neck. The aim of the present study was to analyze the incidence and clinical relevance of late lymph node metastasis in patients with head and neck cancer. The clinical data of 61 patients with head and neck cancer who had undergone elective ND with pN0 neck were retrospectively analyzed. Only patients without local failure, second primary, or radiochemotherapy were included in the study. Late lymph node metastasis could be observed in 4 (6.5%) cases at the margin or outside the initially dissected lymph node levels. In those patients, the primary tumor was localized in the oral cavity (n = 3) or oropharynx (n = 1) and was classified in all cases as T1 or T2. Lymph node metastasis could be found in levels I (n = 2), II (n = 1), and IV (n = 1), respectively. Even in the case of pN0 neck after an elective ND, the appearance of late lymph node metastases must be expected. The low proportion of patients with late lymph node metastases after a selective ND in clinical and histologic N0 does not justify an extended form of neck surgery.
Background: The reprocessing of medical devices has become more complex due to increasing hygiene requirements. Previous studies showed satisfactory bactericidal disinfection effects of UV-C light in rigid and flexible endoscopes. Especially in the context of the current COVID-19 pandemic, virucidal properties are of high importance. In the present study, the virucidal efficacy of UV-C light surface disinfection was analyzed. Methods: MS-2 bacteriophages were applied to the test samples and irradiated by UV-C light using the UV Smart D25 device; unirradiated test samples were used as controls. A dilution series of the samples was mixed with Escherichia coli and assayed. Results: 8.6 × 1012 pfu could be harvested from the unprocessed test samples. In the control group without UV-C exposure, a remaining contamination of 1.2 × 1012 pfu was detected, resulting in a procedural baseline reduction rate with a LOG10 reduction factor of 0.72. The LOG10 reduction factor was found to be 3.0 after 25 s of UV-C light exposure. After 50 and 75 s of UV-C radiation LOG10 reduction factors 4.2 and 5.9, respectively, were found, with all reductions being statistically significantly different to baseline. Conclusions: The tested UV system seems to provide a significant virucidal effect after a relatively short irradiation time.
Background: The reprocessing of daily used medical devices is often inadequate, making them a potential source of infection. In addition, there are usually no consistent and technically standardized procedures available for this purpose. Hence, the aim of this study is to analyze the bacterial contamination and the effectiveness of Ultraviolet light-based (UV light-based) reprocessing of daily used medical devices. Material and methods: Six different everyday medical devices (20 each; stethoscopes, tourniquets, bandage scissors, reflex hammers, tuning forks, and nystagmus glasses) were tested for bacterial contamination. All medical devices were then exposed to UV-C light for 25 seconds. Medical devices with a smooth surface were pre-cleaned with a water-based wipe. Contact samples were taken before and after reprocessing. Results: Immediately after clinical use, 104 of 120 contact samples showed an average bacterial contamination of 44.8±64.3 colony forming units (CFU) (0–300 CFU), also including potentially pathogenic bacteria. Two further culture media were completely overgrown with potentially pathogenic bacteria. The stethoscopes were found to have the highest average contamination of 90±91.6 CFU. After reprocessing, 118 of 120 samples were sterile, resulting in an average residual contamination of 0.02±0.1 CFU in two samples, whereby only bacteria of the ordinary skin flora were found. Conclusion: The present study shows the potentially clinically relevant bacterial contamination of everyday used medical devices. The reprocessing method tested here using UV light appears to be a suitable method for disinfection, especially for objects that up to now have been difficult to disinfect or cannot be disinfected in a standardized manner.