Hangzhen Lan

Dr. Hangzhen Lan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2022 in Foods
Verified
Journal Article
Open access
PDF file
HXHaoyi Xu
Haoyi Xu
HLHangzhen Lan
Hangzhen Lan
DPDaodong Pan
Daodong Pan
Junfeng XuJunfeng Xu
Junfeng Xu
XWXiaofu Wang
Xiaofu Wang
The aim of this study was to develop an accurate, easy-to-use, and cost-effective method for the detection of chicken adulteration based on polymerase chain reaction (PCR) and lateral flow strip (LFS). We compared six DNA extraction methods, namely the cetyltrimethylammonium bromide (CTAB) method, salt method, urea method, SDS method, guanidine isothiocyanate method, and commercial kit method. The chicken cytb gene was used as a target to design specific primers. The specificity and sensitivity of the PCR-LFS system were tested using a self-assembled lateral flow measurement sensor. The results showed that the DNA concentration obtained by salt methods is up to 533 ± 84 ng µL−1, is a suitable replacement for commercial kits. The PCR-LFS method exhibits high specificity at an annealing temperature of 62 °C and does not cross-react with other animal sources. This strategy is also highly sensitive, being able to detect 0.1% of chicken in artificial adulterated meat. The results of the test strips can be observed with the naked eye within 5 min, and this result is consistent with the electrophoresis result, demonstrating its high accuracy. Moreover, the detection system has already been successfully used to detect chicken in commercial samples. Hence, this PCR-LFS strategy provides a potential tool to verify the authenticity of chicken.

13 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
XZXiaoyan Zhu
Xiaoyan Zhu
JTJiaqi Tong
Jiaqi Tong
HLHangzhen Lan
Hangzhen Lan
DPDaodong Pan
Daodong Pan
Diclofenac sodium (DS), one of the most used non-steroidal anti-inflammatory drugs worldwide, is often detected in wastewater and natural water. This drug is ecotoxic, even at low concentrations. Therefore, it is essential to fabricate low-cost adsorbents that can easily and effectively remove DS from contaminated water bodies. In this study, a polyethyleneimine (PEI)-modified magnetic cellulose nanocrystal (MCNC) was prepared with a silane coupling agent as a bridge. TEM, FTIR, XRD, and VSM were used to demonstrate the successful preparation of MCNC-PEI. This composite adsorbent exhibited efficient DS removal. Furthermore, the adsorption performance of MCNC-PEI on DS was optimal under mildly acidic conditions (pH = 4.5). Adsorption kinetics showed that the adsorption process involves mainly electrostatic interactions. Moreover, the maximum adsorption capacity reached 299.93 mg/g at 25 °C, and the adsorption capacity only decreased by 9.9% after being reused five times. Considering its low cost, low toxicity, and high DS removal capacity, MCNC-PEI could be a promising adsorbent for treating DS-contaminated water.

24 September 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
SYSong Yan
Song Yan
HLHangzhen Lan
Hangzhen Lan
ZWZhen Wu
Zhen Wu
YSYangying Sun
Yangying Sun
MTMaolin Tu
Maolin Tu
DPDaodong Pan
Daodong Pan

8 March 2024 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
PYPeixun Yang
Peixun Yang
XZXiaoyan Zhu
Xiaoyan Zhu
HLHangzhen Lan
Hangzhen Lan
YWYichun Wu
Yichun Wu
DPDaodong Pan
Daodong Pan

28 January 2023 in Foods
Verified
Journal Article
Open access
PDF file
MCMengfei Chen
Mengfei Chen
HLHangzhen Lan
Hangzhen Lan
DPDaodong Pan
Daodong Pan
TZTao Zhang
Tao Zhang
In this study, a functionalized mesoporous silica-coated solid-phase microextraction (SPME) Arrow system was developed for the enrichment of six biogenic amines (BAs) from pork and fish samples before gas chromatographic separation with a mass spectrometer as a detector. MCM-41 was utilized as the substrate material and thereby functionalized by titanate and sodium dodecyl sulfate to adjust its surface acidity and hydrophobicity, respectively. The functionalized MCM-41 (named as MCM-T-H) was coated on a bare SPME Arrow using the dipping method and polyacrylonitrile was used as the adhesive. The extraction capacity and selectivity of the MCM-T-H-SPME Arrow for six kinds of derivatized BAs were studied and compared with commercial SPME Arrows. Experimental parameters, e.g., sample volume, derivatization reagent amount, extraction time, and desorption time, which have a dramatic effect on SPME Arrow pretreatment, were optimized. Acidity enhanced MCM-T-H coating showed a much higher affinity to derivatized BAs compared to a commercial SPME Arrow in terms of extraction capacity. In addition, hydrophobicity modification significantly reduced the interference of water molecules on the interaction between MCM-T-H and the derivatized BAs. The MCM-T-H-SPME Arrow showed efficient separation and enrichment capacity for derivatized BAs from complex matrices and therefore, the sample pretreatment time was saved. According to the experimental results, the optimal condition was to add 10 μL derivatization reagent to a 10 mL sample and maintain an agitation speed of 1250 r min−1. The MCM-T-H-SPME showed excellent reproducibility (RSD < 9.8%) and fast adsorption kinetics (30 min) and desorption kinetics (5 min) for derivatized BAs under optimal conditions. In summary, the MCM-T-H-SPME Arrow based method was employed for accurate monitoring of the variations of BAs in pork and fish, and good results were achieved.

26 October 2022 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
MLMan Lu
Man Lu
HLHangzhen Lan
Hangzhen Lan
ZCZhendong Cai
Zhendong Cai
ZWZhen Wu
Zhen Wu
YSYangying Sun
Yangying Sun
DPDaodong Pan
Daodong Pan