Adina Milena Tatar

Adina Milena Tatar

Auto-generated profile, based on publicly available information

Adina Milena Tatar


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
DPDRAGOS PASCULESCU
DRAGOS PASCULESCU
Simona RiureanSimona Riurean
Simona Riurean
MIMILA ILIEVA-OBRETENOVA
MILA ILIEVA-OBRETENOVA
Teodora LazarTeodora Lazar
Teodora Lazar
ATAdina Milena Tatar
Adina Milena Tatar
NFNicolae Daniel Fîţă
Nicolae Daniel Fîţă
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink R2022b on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.

14 February 2026 in Processes
Verified
Journal Article
Open access
PDF file
LCLAZAR DAN CRISTIAN
LAZAR DAN CRISTIAN
DPDan Codrut Petrilean
Dan Codrut Petrilean
Teodora LazarTeodora Lazar
Teodora Lazar
FPFlorin Gabriel Popescu
Florin Gabriel Popescu
DIDaria Ionescu
Daria Ionescu
DPDRAGOS PASCULESCU
DRAGOS PASCULESCU
The transition toward active distribution networks requires advanced control solutions capable of handling the rapid dynamics of distributed energy resources. This paper proposes a low-cost, intelligent IoT architecture designed for the real-time optimization and analysis of energy systems within low-voltage networks. Unlike centralized monitoring approaches constrained by communication latency, the proposed solution leverages Intelligent Edge Processing (IEP) implemented on ESP32 embedded nodes to optimize data flow and decision-making. This architecture executes stability assessments directly at the network edge, calculating critical analysis indicators such as the Voltage Deviation Index (VDI) and Rate of Change of Frequency (RoCoF). The system was validated on the CIGRE European LV benchmark under severe stress scenarios, including rapid solar transients and voltage sags. The results demonstrate that the proposed architecture effectively coordinates storage interventions, ensuring voltage recovery within 300 ms and maintaining power quality within EN 50160 limits even during severe voltage sags. The study validates the feasibility of using industrial IoT edge computing as a resilient, non-wire alternative for modernizing complex energy systems.

2 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
Teodora LazarTeodora Lazar
Teodora Lazar
DIDaria Ionescu
Daria Ionescu
LCLAZAR DAN CRISTIAN
LAZAR DAN CRISTIAN
FPFlorin Gabriel Popescu
Florin Gabriel Popescu
ATAdina Milena Tatar
Adina Milena Tatar
DPDRAGOS PASCULESCU
DRAGOS PASCULESCU
The rapid proliferation of single-phase non-linear loads, such as LED lighting and IT equipment, in modern Smart Buildings has introduced significant power quality challenges in low-voltage electrical installations. A critical but often underestimated consequence is the severe overloading of the neutral conductor caused by triplen harmonics (particularly the 3rd harmonic), which sum algebraically even in balanced three-phase systems. This paper analyzes the electrical and thermal impact of these distortions using a detailed MATLAB/Simulink model of a 400/230 V (3P + N) network. The simulation results demonstrate that under highly distorted conditions (Scenario S3), the neutral current can reach 180% of the nominal phase current (18 A vs. 10 A). Furthermore, the Joule losses analysis reveals a thermal stress more than three times higher on the neutral conductor (peak ~65 W) compared to the phase conductor (~20 W), challenging the traditional design practice of neutral undersizing. To address these safety issues, this study proposes a novel neutral-to-phase current ratio index (kN) and a proactive decision matrix for Building Management Systems (BMS). Unlike traditional mitigation strategies that rely on static hardware oversizing, passive filters, or specialized transformers, the proposed approach offers a dynamic, cost-effective, and software-driven solution that can be easily integrated into the existing automation infrastructure of modern Smart Buildings. The model identifies a critical tipping point at a 3rd harmonic content of 35.3%, where kN ≥ 1. By continuously monitoring the kN parameter, the proposed algorithm enables a transition from passive protection to active power management, triggering automated responses to prevent insulation degradation and mitigate fire hazards.

13 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
DPDRAGOS PASCULESCU
DRAGOS PASCULESCU
Simona RiureanSimona Riurean
Simona Riurean
MIMILA ILIEVA-OBRETENOVA
MILA ILIEVA-OBRETENOVA
Teodora LazarTeodora Lazar
Teodora Lazar
ATAdina Milena Tatar
Adina Milena Tatar
NFNicolae Daniel Fîţă
Nicolae Daniel Fîţă
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.

31 March 2024 in Journal of Research and Innovation for Sustainable Society
Verified
Journal Article
Closed access
CICristina Ionici
Cristina Ionici
NMNicoleta Mihuț
Nicoleta Mihuț
ATAdina Tătar
Adina Tătar

30 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Teodora LazarTeodora Lazar
Teodora Lazar
DIDaria Ionescu
Daria Ionescu
ATAdina Milena Tatar
Adina Milena Tatar
LCLAZAR DAN CRISTIAN
LAZAR DAN CRISTIAN
ONOtilia Nedelcu
Otilia Nedelcu
DPDRAGOS PASCULESCU
DRAGOS PASCULESCU
Hybrid PV–BESS microgrids represent a promising solution for enhancing energy resilience; however, the implementation of black-start functions in such architectures remains a complex challenge, particularly in the presence of medium-voltage transformers and grid-following photovoltaic sources. This paper proposes and evaluates, through MATLAB/Simulink simulation, a black-start strategy for a hybrid microgrid derived from the architecture of a real 31.59 MWp photovoltaic power plant connected through a 20 kV collector network. The strategy is based on a BESS operated in grid-forming mode, responsible for voltage and frequency formation, controlled energization of the internal infrastructure, and support of the initial restoration stages, while the photovoltaic groups are synchronized at a later stage in order to reduce the energy burden imposed on the storage system. The methodology combines controlled voltage ramping for transformer inrush current mitigation, hybrid PV–BESS restoration, robustness evaluation under irradiance variation, sequential load restoration, and staged energization of the internal stations TS1–TS5. The results show that the soft-start strategy reduces the maximum instantaneous current of transformer TS2 from 188.3620 A to 0.3515 A and the maximum current of the BESS source from 4729.2 A to 57.7929 A. In the hybrid scenario, after photovoltaic source synchronization at 7 s, PV power rises to 2.75 MW, while the power supplied by the BESS decreases from 3.00 MW to 0.25 MW. The analysis of irradiance variation confirms the increased energy dependence on the BESS under reduced solar resource conditions, while sequential load restoration demonstrates the feasibility of controlled reconnection up to 30.25 MW. Overall, the study confirms that the proposed architecture and staged control logic provide a feasible and transferable framework for enhancing the resilience of large-scale photovoltaic power plants based on hybrid PV–BESS microgrids.