Farshad Oveissi

Dr. Farshad Oveissi

School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney 2006, Australia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
JGJacopo E. Giaretta
Jacopo E. Giaretta
HDHaowei Duan
Haowei Duan
Farshad OveissiFarshad Oveissi
Farshad Oveissi
Syamak FarajikhahSyamak Farajikhah
Syamak Farajikhah
Fariba DehghaniFariba Dehghani
Fariba Dehghani
Sina NaficySina Naficy
Sina Naficy
Hydrogen peroxide (H2O2) is a common chemical used in many industries and can be found in various biological environments, water, and air. Yet, H2O2 in a certain range of concentrations can be hazardous and toxic. Therefore, it is crucial to determine its concentration at different conditions for safety and diagnostic purposes. This review provides an insight about different types of sensors that have been developed for detection of H2O2. Their flexibility, stability, cost, detection limit, manufacturing, and challenges in their applications have been compared. More specifically the advantages and disadvantages of various flexible substrates that have been utilized for the design of H2O2 sensors were discussed. These substrates include carbonaceous substrates (e.g., reduced graphene oxide films, carbon cloth, carbon, and graphene fibers), polymeric substrates, paper, thin glass, and silicon wafers. Many of these substrates are often decorated with nanostructures composed of Pt, Au, Ag, MnO2, Fe3O4, or a conductive polymer to enhance the performance of sensors. The impact of these nanostructures on the sensing performance of resulting flexible H2O2 sensors has been reviewed in detail. In summary, the detection limits of these sensors are within the range of 100 nM-1 mM, which makes them potentially, but not necessarily, suitable for applications in health, food, and environmental monitoring. However, the required sample volume, cost, ease of manufacturing, and stability are often neglected compared to other detection parameters, which hinders sensors' real-world application. Future perspectives on how to address some of the substrate limitations and examples of application-driven sensors are also discussed.

1 December 2022 in Advanced Engineering Materials
Verified
Journal Article
Open access
RRRonil J. Rath
Ronil J. Rath
Syamak FarajikhahSyamak Farajikhah
Syamak Farajikhah
Farshad OveissiFarshad Oveissi
Farshad Oveissi
Fariba DehghaniFariba Dehghani
Fariba Dehghani
Sina NaficySina Naficy
Sina Naficy
Gas detection and monitoring are essential due to their direct impact on human health, environment, and ecosystem. Chemiresistive sensors are one of the most used classes of sensors for monitoring and measurement of gases thanks to their ease of fabrication, customizability, mechanical flexibility, and fast response time. While chemiresistive sensors can offer good sensitivity and selectivity to a particular gas in a controlled environment with known interferences, they may not be able to differentiate between various gases having similar physiochemical properties under uncontrolled conditions. To address this shortcoming of chemiresistive gas sensors, sensor arrays have been the subject of recent studies. Gas sensor arrays are a group of individual gas sensors that are arranged to simultaneously detect and differentiate multiple cross‐reactive gases. In this regard, various sensor array technologies have been developed to differentiate a given set of gases using multivariate algorithms. This review provides an insight into the different algorithms that are used to extract the data from the sensor arrays, highlighting the fabrication techniques used for developing the sensor array prototypes, and different applications in which these arrays are used.

1 January 2020 in Materials Today Bio
Verified
Journal Article
Open access
Farshad OveissiFarshad Oveissi
Farshad Oveissi
Sina NaficySina Naficy
Sina Naficy
ALA. Lee
A. Lee
DWDavid Winlaw
David Winlaw
Fariba DehghaniFariba Dehghani
Fariba Dehghani
Valvular heart diseases (VHD) are a major health burden, affecting millions of people worldwide. The treatments for such diseases rely on medicine, valve repair, and artificial heart valves including mechanical and bioprosthetic valves. Yet, there are countless reports on possible alternatives noting long-term stability and biocompatibility issues and highlighting the need for fabrication of more durable and effective replacements. This review discusses the current and potential materials that can be used for developing such valves along with existing and developing fabrication methods. With this perspective, we quantitatively compare mechanical properties of various materials that are currently used or proposed for heart valves along with their fabrication processes to identify challenges we face in creating new materials and manufacturing techniques to better mimick ​the performance of native heart valves.

18 June 2020 in ACS Sensors
Verified
Journal Article
Closed access
LNLong H. Nguyen
Long H. Nguyen
Farshad OveissiFarshad Oveissi
Farshad Oveissi
Rona  ChandrawatiRona Chandrawati
Rona Chandrawati
Fariba DehghaniFariba Dehghani
Fariba Dehghani
Sina NaficySina Naficy
Sina Naficy

7 November 2018 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
Farshad OveissiFarshad Oveissi
Farshad Oveissi
Sina NaficySina Naficy
Sina Naficy
TLThi Yen Loan Le
Thi Yen Loan Le
DFDavid F Fletcher
David F Fletcher
Fariba DehghaniFariba Dehghani
Fariba Dehghani

10 September 2018 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
Sina NaficySina Naficy
Sina Naficy
Farshad OveissiFarshad Oveissi
Farshad Oveissi
BPBianca Patrick
Bianca Patrick
ASAaron Schindeler
Aaron Schindeler
Fariba DehghaniFariba Dehghani
Fariba Dehghani