Shameen Ashfaq

Dr. Shameen Ashfaq


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Supat ChupraditSupat Chupradit
Supat Chupradit
SAShameen Ashfaq
Shameen Ashfaq
Dmitry BokovDmitry Bokov
Dmitry Bokov
Wanich SuksatanWanich Suksatan
Wanich Suksatan
Abduladheem Turki JalilAbduladheem Turki Jalil
Abduladheem Turki Jalil
Mika E.T. SillanpääMika E.T. Sillanpää
Mika E.T. Sillanpää
This study proposes a refractive index sensor for the simultaneous detection of cancer and diabetes based on photonic crystals (PhC). The proposed PhC composed of silicon rods in the air bed arranged in a hexagonal lattice forms the fundamental structure. Two tubes are used to place the cancerous or diabetic samples for measurement. The sensor’s transmission characteristics are simulated and analyzed by solving Maxwell’s electromagnetic equations using the finite-difference time-domain approach for samples being studied. Therefore, diabetes and cancer are detected according to the changes in the refractive index of the samples using the laser source centered at 1550 nm. Considering the findings, the sensor’s geometry changes to adjust the suggested sensitivity and quality factor of structure. According to the results, transmission power ranges between 91 and 100% based on the sample. Moreover, sensitivity ranges from 1294 to 3080 nm/RIU and the maximum Figure of Mertie is nearly FOM = 1550.11 ± 150.11 RIU−1 with the detection in range 31 × 10−6 RIU. In addition, the small area (61.56 μm2) of biosensor results in its appropriateness for different uses in compact photonic integrated circuits. Next, we changed the shape of the dielectric rods and investigated their effects on the sensitivity parameter. The sensitivity and figure of merit after changes in the shape of dielectric rods and nanocavities are at best S = 20,393 nm/RIU and FOM = 9104.017 ± 606.93 RIU−1, receptively. In addition, the resolution detection range is 203.93 × 10−6 RIU.

17 December 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Abduladheem Turki JalilAbduladheem Turki Jalil
Abduladheem Turki Jalil
SAShameen Ashfaq
Shameen Ashfaq
Dmitry BokovDmitry Bokov
Dmitry Bokov
AAAmer Alanazi
Amer Alanazi
Kadda HachemKadda Hachem
Kadda Hachem
Mika E.T. SillanpääMika E.T. Sillanpää
Mika E.T. Sillanpää
In this work, a novel structure of an all-optical biosensor based on glass resonance cavities with high detection accuracy and sensitivity in two-dimensional photon crystal is designed and simulated. The free spectral range in which the structure performs well is about FSR = 630 nm. This sensor measures the concentration of glucose in human urine. Analyses to determine the glucose concentration in urine for a normal range (0~15 mg/dL) and urine despite glucose concentrations of 0.625, 1.25, 2.5, 5 and 10 g/dL in the wavelength range 1.326404~1.326426 μm have been conducted. The detection range is RIU = 0.2 × 10−7. The average bandwidth of the output resonance wavelengths is 0.34 nm in the lowest case. In the worst case, the percentage of optical signal power transmission is 77% with an amplitude of 1.303241 and, in the best case, 100% with an amplitude of 1.326404. The overall dimensions of the biosensor are 102.6 µm2 and the sensitivity is equal to S = 1360.02 nm/RIU and the important parameter of the Figure of Merit (FOM) for the proposed biosensor structure is equal to FOM = 1320.23 RIU−1.

18 October 2024 in Coatings
Verified
Journal Article
Open access
PDF file
Supat ChupraditSupat Chupradit
Supat Chupradit
SAShameen Ashfaq
Shameen Ashfaq
Dmitry BokovDmitry Bokov
Dmitry Bokov
WSWanich Suksatan
Wanich Suksatan
Abduladheem Turki JalilAbduladheem Turki Jalil
Abduladheem Turki Jalil
Mika E.T. SillanpääMika E.T. Sillanpää
Mika E.T. Sillanpää
The journal retracts the article, “Ultra-Sensitive Biosensor with Simultaneous Detection (of Cancer and Diabetes) and Analysis of Deformation Effects on Dielectric Rods in Optical Microstructure”

24 November 2025 in Coatings
Verified
Journal Article
Open access
PDF file
AJAbduladheem Turki Jalil
Abduladheem Turki Jalil
SAShameen Ashfaq
Shameen Ashfaq
Dmitry BokovDmitry Bokov
Dmitry Bokov
AAAmer Alanazi
Amer Alanazi
Kadda HachemKadda Hachem
Kadda Hachem
Mika E.T. SillanpääMika E.T. Sillanpää
Mika E.T. Sillanpää
The journal retracts the article entitled “High-Sensitivity Biosensor Based on Glass Resonance PhC Cavities for Detection of Blood Component and Glucose Concentration in Human Urine”