junkai bai

Dr. junkai bai

Xidian University, Xi'an, Shaanxi Province
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2021 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
XWXinran Wang
Xinran Wang
HGHongfu Guo
Hongfu Guo
CZChen Zhou
Chen Zhou
JBjunkai bai
junkai bai
Background: In order to use the microwave to measure the dielectric constant of the human body and improve the measurement resolution, a small near-field probe working at 915 MHz is designed in this paper. Method: Based on the electric small loop antenna model loaded by the spiral resonator (SR), a small near-field probe was designed. The probe model is designed and optimized by the HFSS (high frequency structure simulator) software. The human tissues were tested by the manufactured probe and the relationship between the S11 parameters of the probe and the human tissues was analyzed. Results and conclusions: A probe with small size was designed and fabricated, with the overall size of 10.0 mm × 12.0 mm × 0.8 mm. The probe has a good performance with a 30.7 dB return loss, a 20 MHz bandwidth at the resonance point, and a distance resolution of 10 mm. Due to the small size and good resolution of the probe, it can be used in the measurement of human tissues.

12 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JBjunkai bai
junkai bai
HGHongfu Guo
Hongfu Guo
HLHua Li
Hua Li
CZChen Zhou
Chen Zhou
HTHanchao Tang
Hanchao Tang
Point-of-care testing plays an important role in the detection of skin abnormalities. The detection of skin abnormalities requires sufficient depth and no harm. A flexible microwave biosensor based on spoof surface plasmon polaritons was designed to meet the requirements of skin abnormalities. The designed biosensor, which works at 11.3 GHz, is small and can be flexibly attached to the skin surface of any part of the human body for measurement. The health status of the skin can be evaluated by the resonant frequency and the magnitude of the reflection coefficient of the sensor. The sensor was tested on pork skin. The experiment results showed that the sensor can detect skin abnormalities such as skin burn, skin tumor, and others. Compared with other sensors, the sensor has sufficient penetration depth because of the strong penetration of microwave electromagnetic waves. It is the first flexible microwave biosensor used for skin, which involves point-of-care testing, and continuous monitoring of skin.

11 June 2025 in IEEE Access
Verified
Journal Article
Open access
JBjunkai bai
junkai bai
HGHongfu Guo
Hongfu Guo
XLXuerui Lai
Xuerui Lai
The application of microwave sensors in skin tumor detection has attracted a great deal of interest from researchers due to its safety, sensitivity, non-invasiveness, and low cost. In this research, an electrically controlled two-dimensional microwave sensor array based on a complementary spiral resonator (CSR) for skin tumor detection is proposed. The detection is based on the resonant frequency shift of CSR caused by the skin tumor under test. The 10 × 10 CSRs excited by spoof surface plasmon polaritons (SSPPs) are etched on the ground as the sensing elements for sensing skin tissue under test. Each sensing element represents a pixel, and all the sensing elements together form a dielectric image of the tissue. They are independently controlled by the corresponding PIN diodes, which are conveniently controlled by an external controller. The introduction of electrical scanning allows the quick detection of skin tumors without mechanical scanning, greatly improving the detection efficiency. In addition, each sensing element senses the corresponding skin area highly independently under the control of the PIN diode, weakening mutual interference between the elements during the measurement. Compared to the frequency multiplexed sensor array, the sensing elements’ number of the designed sensor array is greatly improved while maintaining the sensing elements’ size consistent. The operating principle of the sensor array is analyzed in detail and numerically simulated in electromagnetic simulation software. Several experiments were performed on tissue phantoms to validate the effectiveness of the designed sensor array.