The paper discusses the structural behaviour of concrete-filled steel tube columns (CFT) when applied to the top-down construction method as temporary internal supports for ceilings. Their ultimate capacity to take into account the actual boundary conditions of the column is essential for successful application in construction. The paper presents the full-scale in situ testing of four slender specimens with variable D/t ratios under concentric axial loading. The CFT columns were supported on the previously jacked concrete piles. In addition, detailed finite element numerical models in ABAQUS and PLAXIS computer programs were developed. The models include the nonlinear behaviour of materials and the nonlinear behaviour of soil. The soil–pile–column interaction and impact of the CFT column–pile connection stiffness on global column stability were considered. The numerical model was validated by comparison with the experimental results. In conclusion, the coefficient for the effective buckling length of the studied columns is proposed. Finally, the experimental results of the critical buckling forces were compared with widely used international design codes Eurocode 4-EC4, American standard-ACI and the Australian standard-AS.
1 June 2017 in Tehnicki vjesnik - Technical Gazette
This paper focuses on the experimental investigation of the axial load capacity of CFT (concrete-filled steel tube) columns under actual construction conditions during building reconstruction. A total of four samples were loaded up to failure. The varied parameters were the column length and absence/presence of the concrete infill within the steel tube. Further, the analysis is extended to developing a numerical model in the finite element-based software ABAQUS version 6.9. This numerical model includes material and geometrical nonlinearities and was validated with the experimental results. The contribution of the concrete core to the column capacity and the concrete core confinement effect are discussed. Finally, the column capacity was calculated according to several design codes: the Eurocode 4 with and without considering the confinement effect, American specifications, Australian standards, the American Institute of Steel Construction, and the Architectural Institute of Japan. The Eurocode 4 considering the confinement effect provides the closest results to those obtained in the tests.
1 January 2018 in Građevinski materijali i konstrukcije
In this paper, results of experimental investigation of bearing capacity and stability of slender and moderately slender CFT circular tubes are presented. The effects of ratio thickness/ radius of steel cross section and support conditions are investigated. Numerical simulation for the tested examples was performed in computer program ABAQUS. In this simulations, nonlinear constitutive models were used for modelling of concrete, steel and concrete/steel connection. With modified Rick's method critical buckling force for the CFT column was calculated. Verification of the obtained experimental results was performed with comparison with several world standards: EC4, ACI, AS, AISC, as well as with the results obtained in ABAQUS.