The estimation of indoor thermal comfort and the associated occupant feedback in office buildings is important to provide satisfactory and safe working environments, enhance the productivity of personnel, and to reduce complaints. The assessment of thermal comfort is a difficult task due to many environmental, physiological, and cultural variables that influence occupants’ thermal perception and the way they judge their working environment. Traditional physics-based methods for evaluating thermal comfort have shown shortcomings when compared to actual responses from the occupants due to the incapacity of these methods to incorporate information of various natures. In this paper, a hybrid approach based on machine learning and building dynamic simulation is presented for the prediction of indoor thermal comfort feedback in an office building in Le Bour-get-du-Lac, Chambéry, France. The office was equipped with Internet of Things (IoT) environmental sensors. Occupant feedback on thermal comfort was collected during an experimental campaign. A calibrated building energy model was created for the building. Various machine learning models were trained using information from the occupants, environmental data, and data extracted from the calibrated dynamic simulation model for the prediction of thermal comfort votes. When compared to traditional predictive approaches, the proposed method shows an increase in accuracy of about 25%.
11 October 2022 in IEEE Transactions on Industry Applications
Potential solutions for unlocking operational flexibility from data centres are investigated. Two types of data centres, in terms of their cooling facilities, are modelled in order to provide an in-depth assessment of potential variations in data centre performance based on their energy consumption and server temperatures. Using synthetic datasets generated from year-long building dynamic simulations under distinct system conditions, four machine learning (ML) models are designed and trained to predict data centre energy consumption and server temperatures. Three different ML algorithms are considered, including random forest, XGBOOST, and multiple linear regression, which all achieve high accuracy ranging from 93.8% to 98.1% for the mean absolute percentage error. The resulting ML models are then utilised to represent a system-wide fleet of data centres, which are integrated within a power system unit scheduling framework for potential demand shifting based on (system) carbon intensity. Five alternative flexibility scenarios are introduced and compared, with the objective of determining the achievable flexibility from a system-wide portfolio of data centres, focusing on concerns relating to server temperatures. On average, a $6.5\%$ load reduction is seen to be achievable for a winter day during periods of high CO 2 intensity.
In this paper, an innovative hybrid modelling technique based on machine learning and building dynamic simulation is presented for the prediction of indoor thermal comfort feedback from occupants in an office building in Le Bourget-du-Lac, Chambéry, France. The office was equipped with Internet of Things (IoT) environmental sensors. A calibrated building energy model was created for the building using optimisation tools. Thermal comfort was collected using a portable device. A machine learning (ML) model was trained using collected feedback, environmental data from IoT devices and synthetic datasets (virtual sensors) extracted from a physics-based model. A calibrated energy model was used in co-simulation with the predictive method to estimate comfort levels for the building. The results show the ability of the method to improve the prediction of occupant feedback when compared to traditional thermal comfort approaches of about 25%, the importance of information extracted from the physics-based model and the possibility of leveraging scenario evaluation capabilities of the dynamic simulation model for control purposes.
Implementation of cost-effective energy conservation measures (ECMs) is expected to generate up to 18% of carbon emissions reductions in office buildings. In order to determine adequate ECMs for a specific building, operational data is required. However, buildings generally lack operational data in the form of time series that can limit a breath of analysis required for determining adequate ECMs. Energy time-series data is commonly lacking in the UK due to uneven availability of smart meters (heat, gas, water), security restrictions in Energy Information Systems (EIS) and building management systems (BMS), restrictions and costs associated for automated reporting from utility companies, etc. This work presents a non-intrusive computer vision-based reader to generate energy readings at 10-minute resolution using a Raspberry-Pi, a traditional webcam and an LED light. OpenCV, an open source computer vision library, is used to detect and interpret numeric values from a heat meter, which are in turn uploaded to a cloud-based energy platform to create a complete operational data set enabling detailed analytics, fault detection and diagnostics (FDD) and model calibration. A case study of an office building in Scotland is presented. The building has a heat meter with no remote access capabilities. The accuracy of the method, i.e. the ability of the script to accurately derive the rate of change between readings, resulted on a 92% percent during a test done for 100 samples. Recommendations for accuracy improvements are included in the conclusions.