Compared with traditional single-view and radiometric-only observations, multiangle polarimetric observations of water-leaving radiation play a crucial role in enhancing the retrieval of ocean constituents and aerosol microphysical properties. In this study, the impacts of uncertainties in the degree of polarization (DOP) of water-leaving radiance (Lw) on the retrieval of oceanic constituents and inherent optical properties (IOPs) were investigated via global radiative transfer (RT) simulations and the fully connected U-Net (FCUN) model. The uncertainties in the retrieval of oceanic constituents and IOPs were further investigated with various sensor azimuth angles. The results indicated that the global mean absolute percentage errors (MAPEs) for differing oceanic constituents and IOPs significantly decreased as the number of observation angles increased. Taking the retrieval of Chla as an example, the global MAPEs between the FCUN predictions and RT simulation inputs for Chla concentrations under differing observation angles were 7.41%, 3.76%, 2.70%, 2.44%, 2.62%, and 1.82%. Moreover, the MAPEs at sensor azimuth angles of 0° and 30° were significantly lower than those at other azimuth angles for the single-view observations. As the number of observation angles increased, the variation in MAPEs with the sensor azimuth angle gradually weakened. Furthermore, the impact of errors in the Lw DOP on the retrieval uncertainties decreased as the number of observation angles increased, and the global MAPEs of Chla after adding the various random instrument noises were 46.56% (46.91%), 6.59% (7.21%), 5.21% (5.79%), 4.72% (4.98%), 3.99% (4.52%), and 3.64% (4.03%). Overall, the multiangle polarimetric observations can suppress or balance the impact of uncertainties in the Lw DOP on the retrieval of oceanic constituents and IOPs.
An advanced Dyson spectrometer is proposed that redesigns the Dyson prism to make the entire system coaxial and easy to implement for each subassembly, thus greatly enhancing optical design, optical processing, and system alignment. The design concept and fabrication methods, as well as the results of imaging evaluations of the proposed spectrometer, are described in detail. At present, the advanced Dyson spectrometer has been in orbit for more than a year, serving smart agriculture and marine applications. The advanced imaging spectrometer achieves high resolution in both the spectral and spatial directions and low spectral distortion at a high numerical aperture in the working waveband. On the basis of the above research, we have developed three other imaging spectrometers with different performance indicators, including a space-based instrument, an airborne instrument and a ground-based instrument, thus verifying the progress and versatility of advanced Dyson spectrometer technology.
Curved prisms can serve as core components of dispersive spectroscopy and converge light paths, making them widely used in spectral imaging technology. Their positional stability, surface shape errors, and temperature stability in optical systems directly affect the performance of spectral imaging systems. On the basis of the analysis of design indicators and optimization of the support structure for curved prisms, a multipoint flexible adhesive support structure (MPPASS) of large rectangular curved prisms for space-based application is proposed. The novelty of the MPPASS lies in its ability to achieve micro-stress and high stability support for large-aperture rectangular optical elements through the bonding of peripheral small points and the introduction of flexible bonding rings. The design principles of the adhesive support structure were deeply studied, and on this basis, the engineering design, finite element analysis, adhesive testing, and mechanical testing of large curved prisms were completed. The designed curved prism assembly has a maximum deformation displacement of 0.0085 mm and a maximum tilt angle of 0.65” under gravity loading, a first-order frequency of 1003.5 Hz, and a maximum acceleration amplification factor of 3.12 in the X, Y, and Z directions. The root mean square (RMS) variation value of the mirror shape errors for the curved prism assembly was 5.26 nm under a uniform temperature load of 20 ± 1 °C, and the RMS value of the mirror shape errors was 0.019 λ after mechanical testing. The installation surface flatness of 0.02 mm did not significantly affect its mirror shape errors. The experimental results verified the rationality of the design, temperature stability, and mechanical stability of the MPPASS.