Qianyi Liu

Dr. Qianyi Liu

School of Automation, Central South University, Changsha 410083, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Qianyi LiuQianyi Liu
Qianyi Liu
YLYong Li
Yong Li
LLLongfu Luo
Longfu Luo
YPYanjian Peng
Yanjian Peng
YCYijia Cao
Yijia Cao
This paper presents a new solution of power quality management for the photovoltaic (PV) power plant with the transformer integrated filtering method. The innovation of the PV power plant is that it contains two-stage filtering station, which consists of a box-type transformer with integrated filter and a 110 kV grid-connected transformer based on inductive filtering method. The filtering reactor can be integrated into the box-type transformer as a decoupled winding, so that the modular design of the box-type transformer and the passive filter is realized. Inductive filtering method applied in the grid-connected transformer not only improves the power quality at the point of common coupling, but dampens the harmonic resonance between the passive filter and grid. The hierarchical structure of the PV power plant is introduced firstly. Then, the equivalent circuit model and the mathematical model of the primary and secondary filtering stations are established, respectively. Moreover, the influence of the weak coupling of integrated reactor on the filtering performance is analyzed. The antijamming capabilities of the inductive filtering method and the traditional filtering method are compared under the condition of parameter disturbance. At last, the site tests of the PV power plant with transformer integrated filtering method are made, which show that the PV grid-connected system comprised of the two-stage filtering station has the characteristics of low harmonic emission, high power factor, and stable operation.

21 May 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Qianyi LiuQianyi Liu
Qianyi Liu
YLYong Li
Yong Li
SHSijia Hu
Sijia Hu
LLLongfu Luo
Longfu Luo
This paper proposes a transformer integrated filtering system (TIFS) for harmonic suppression in the industrial dc supply system. Designed for the electric environment with large current and severe harmonic contamination and the installation space with restricted planning area, the proposed TIFS has the merits of lower transformer loss, stronger ability in harmonic elimination, and higher integration of the electric equipment in the high-power industrial applications. The winding arrangement of the inductive filtering transformer with integrated reactor is introduced. Considering the influence of the residual weak coupling, the electromagnetic decoupling model of TIFS is established. Then, the interaction between the zero-impedance designed filtering winding and the decoupled winding is analyzed to determine the restricted range of the design parameter. The control strategy together with the transformer design method is further illuminated. At last, the prototype of TIFS is established in the laboratory. The experimental results verify the feasibility and effectiveness of the proposed filtering method.

10 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Qianyi LiuQianyi Liu
Qianyi Liu
Fang LiuFang Liu
Fang Liu
RZRunmin Zou
Runmin Zou
YLYong Li
Yong Li
Harmonic amplification and interaction of the PV plant which contains multiple parallel inverters influence the renewable power generation and operation seriously. In this article, the resonance mechanism and characteristics of a real large-scale PV plant are explored based on its plant-level circuit model. The component and system models are established first. The distribution rules of wideband resonance frequency from the perspective of the point of common coupling (PCC) and the inverter are respectively determined. Two different resonance bands excited by LCL filter and underground cable are further identified. At last, the practical case of harmonic resonance in the studied PV plant is investigated. Both the measured data and the simulation results support the analytical conclusions. This article combines the theoretical study with the engineering practice, which provides beneficial guidance on the resonance prevention.

1 February 2019 in Control Engineering Practice
Verified
Journal Article
Closed access
Qianyi LiuQianyi Liu
Qianyi Liu
YLYong Li
Yong Li
SHSijia Hu
Sijia Hu
LLLongfu Luo
Longfu Luo

9 August 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Fang LiuFang Liu
Fang Liu
HLHaotian Li
Haotian Li
Qianyi LiuQianyi Liu
Qianyi Liu
KLKang-Zhi Liu
Kang-Zhi Liu
DLDanyun Li
Danyun Li
The original model-based wide-area damping control (WADC) is difficult to obtain good damping performance due to the complex structure of interconnected power systems. In this paper, an improved data-driven model-free adaptive control (ID-MFAC) algorithm is proposed to design WADC for interconnected power systems with stochastic communication delays. First, the multiple-input multiple-output power system can be decoupled as multiple single-input single-output subsystems by considering controller interactions and system disturbances. Second, a step-size vector is designed to adjust the pseudo-partial derivative and make the algorithm more flexible by considering both input and output data adequately. Furthermore, an adaptive delay compensator is designed to compensate stochastic communication delays. Last, simulations are conducted to verify that the ID-MFAC algorithm can efficiently suppress multiple inter-area oscillations modes under various stochastic communication delays.

4 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YWYun Wang
Yun Wang
JWJiazhi Wang
Jiazhi Wang
FLFulin Liu
Fulin Liu
Qianyi LiuQianyi Liu
Qianyi Liu
RZRunmin Zou
Runmin Zou
A resistor–inductor–inductor (RLL) snubber is proposed for high-power power electronic devices that use insulated gate bipolar transistors (IGBTs) in parallel. The RLL snubber provides current sharing for parallel IGBTs by utilizing series inductors to decrease the rate of current change in turn- on and turn- off transients. Compared with other methods, the proposed snubber incorporates only passive components without additional sensors or control circuits, which shows its advantages of simple structure, strong applicability, and easy implementation. In order to further expand its application scope, the topologies of RLL snubber for multiple IGBTs in parallel are designed and improved. Experimental results of 5 and 6 parallel IGBTs validate the feasibility and effectiveness of the proposed snubber.