Taken as a whole, the indoor environmental quality (IEQ) is a concept that deals not only with thermal conditions, but it also goes much further, because it includes indoor air quality (IAQ), illuminance or acoustic comfort. Among the different categories of buildings, schools are one of the most important in society especially because future generations are spending more than 6 h/day and ensuring them a healthy and comfortable environment must be top priority. The purposes of this research were to better understand school children’s IEQ preferences and needs in classrooms and to compare these among rural versus urban respondents. To reach this goal, a simple yet complete survey was proposed and, along with measurements, multiple conclusions were made. The methodology proposed was to reach a large sample of respondents to give more credibility and precision to the analysis. The results are based on the responses of 790 occupants both from urban and rural environments. Lack of ventilation, cooling, low or too high temperatures during winter/summer periods and a misappropriate sizing or piloting of the heating system are some of the issues found during the survey. The paper tackles several issues at once, helping to paint a more holistic image of the problems encountered in school classrooms. Optimal thermal comfort is not met during the cold season in any of the schools under investigation. The old rural schools were found to be the worst performing buildings compared to urban schools where due to recent investments in refurbishment the winter thermal comfort was enhanced. During the study, it was observed that one of the major IAQ problems consisted in elevated levels of CO2 or particulate matter especially for the schools situated in the city. Noise was reported as an issue only for the schools situated next to national roads while visual comfort was found to be acceptable for more than 94% of respondents from all regions.

5 December 2022 in Toxics
Verified
Journal Article
Open access
PDF file
LPLelia Letitia Popescu
Lelia Letitia Popescu
RPRǎzvan Ştefan Popescu
Rǎzvan Ştefan Popescu
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
Air pollution risk factor on human health was surpassed only by high blood pressure, tobacco use and poor diet. Total number of deaths due to air pollution worldwide was estimated to 6.67 million people in 2019. In the European Union, 97% of the urban population is exposed to levels of fine particulate matter above the latest guideline levels set by the World Health Organization. Air pollution accounts for 20% of newborn deaths worldwide, most related to complications of low birth weight and preterm birth. Low birth weight and preterm birth are responsible for 1.8 million deaths worldwide. Bucharest is the capital city of Romania and one of the most polluted cities in Europe, ranking in the 9th position out of 96 of the top cities from Europe and in the 4th position out of 32 of the top cities in Eastern Europe, data from June 2022. The aim of this study was to measure the real time level of indoor particulate pollution levels in different indoor environments from Bucharest, during the pandemic period. The PM2.5/PM10 ratio and its rate of change were also determined for the measured data. The PM2.5/PM10 ratio and its rate of change were also calculated based on the measurement data. The PM2.5/PM10 ratio showed an upward trend on weekends compared to weekdays, suggesting a relationship with outdoor PM where leisure activities and traffic infiltrated the indoors. The fluctuation range of the PM2.5/PM10 ratio was 0.44~0.95, and low measured values were detected on weekdays. Of the seasons, the proportion of particulate in autumn and its rate of change tended to be higher than in summer. It was suggested that outdoor air may have permeated the room. In addition, the relationship was considered, such as it is a holiday period, there are few rainy days, the concentration of coarse particles is high, and the number of residents in the city decreases. When it comes to indoor air quality, the higher this ratio, the more serious the air pollution. PM10 concentrations decreased by 29.1% in the absence of human activity and increased by 35.1% in the presence of humans. PM2.5 concentration decreased by 30.3% without human activity and increased by 3.1% with the presence of humans. Certain trends were suggested for the resumption of human activity and an increase in PM2.5 concentrations. The average relative difference between October 2021, a pandemic period, and October 2022, a post pandemic period, was 64% for PM10 and 47% for PM2.5. The pandemic period brought a significantly better indoor air quality from the particulate pollution point of view.

IMIon-Costinel Mareș
Ion-Costinel Mareș
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
MIMarian-Andrei Istrate
Marian-Andrei Istrate
Cucos Alexandra LauraCucos Alexandra Laura
Cucos Alexandra Laura
TDTiberius Dicu
Tiberius Dicu
RPRazvan Stefan Popescu
Razvan Stefan Popescu
The purpose of this article is the assessment of energy efficiency and indoor air quality for a single-family house located in Cluj-Napoca County, Romania. The studied house is meant to be an energy-efficient building with thermal insulation, low U-value windows, and a high efficiency boiler. Increasing the energy efficiency of the house leads to lower indoor air quality, due to lack of natural ventilation. As the experimental campaign regarding indoor air quality revealed, there is a need to find a balance between energy consumption and the quality of the indoor air. To achieve superior indoor air quality, the proposed mitigation systems (decentralized mechanical ventilation with heat recovery combined with a minimally invasive active sub-slab depressurization) have been installed to reduce the high radon level in the dwelling, achieving an energy reduction loss of up to 86%, compared to the traditional natural ventilation of the house. The sub-slab depressurization system was installed in the room with the highest radon level, while the local ventilation system with heat recovery has been installed in the exterior walls of the house. The results have shown significant improvement in the level of radon decreasing the average concentration from 425 to 70 Bq/m3, respectively the carbon dioxide average of the measurements being around 760 ppm. The thermal comfort improves significantly also, by stabilizing the indoor temperature at 21 °C, without any important fluctuations. The installation of this system has led to higher indoor air quality, with low energy costs and significant energy savings compared to conventional ventilation (by opening windows).

12 May 2012 in HVAC&R Research
Verified
Journal Article
Closed access
LPLelia Letitia Popescu
Lelia Letitia Popescu
KLKarim Limam
Karim Limam
Indoor air quality is a major factor as nowadays people spend most of their time in buildings being exposed to the indoor level of pollution. The rate of pollutant entry through a leakage can be expressed by means of a penetration factor. The present article aims to present a numerical model proposed by the authors able to determine the particles’ mass transfer from outside environment to the inside one as a result of a pressure difference between the two zones. The studied cracks had simple rectangular geometry. The chosen cracks’ heights were 1 mm (0.039 in.) and 3 mm (0.118 in.) with a length of 50 mm(1.968 in.). Both horizontal and vertical positions were studied for the crack. According to the reference data, three levels of pressure drops were studied: 1, 3, and 6 Pa. The most dangerous particle diameters span for the human health varies from 0.35 to 2.5 μm, and so we have chosen it. The injected particles were made of a solid with the density of 1050 kg/m 3 (65.54 lb/fi 3 ) and had a spherical shape. A computational fluid dynamics program was used to predict both airflow fields and particles concentration distribution. The geometrical configuration studied in this article aims to reproduce an experimental setup realized by the authors in order to validate the numerical model with the experimental results. The diameters’ span considered in this study didn't show an important influence on the penetration factor for the studied cases. The developed numerical model showed to be stable and gave results in the expected range of experimental values. This numerical study was capable of clarifying some details that are not obvious out of the experimental results, as the particles’ trajectories, or to quantify the crack entrance effect.

3 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SȘSimona Elena Șerban
Simona Elena Șerban
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
RPRazvan Popescu
Razvan Popescu
LPLelia Letitia Popescu
Lelia Letitia Popescu
In Europe, it is estimated that 14% of existing buildings were built before 1919, whereas 26% were built before 1945. In Romania, about 31% of the buildings date from before 1961, contributing to the current stock of old buildings with historic and architectural value in the country. This paper illustrates the current state of buildings with historic and architectural value in Romania, alongside a case study of a representative administrative building in Câmpulung, Romania. The analysis of the Town Hall building in Câmpulung, Romania, demonstrates that potential energy savings of up to 47.53% can be achieved by implementing interventions such as upgrading windows, insulating the attic, and installing photovoltaic panels. The highest energy reduction is obtained by replacing the window glass with a value of 18.16% with attic insulation with a value of 16.1%. This paper also presents indoor measurements of temperature and humidity in different offices positioned in the north and the south. The study conducted on the south façade office revealed consistent temperatures ranging from 21.7 °C to 24.4 °C, with an average of 23.31 °C. However, the humidity levels fluctuated considerably, ranging from 17.1% to 39.1%, with an average of 26.89%. The sun-exposed section of the building saw relatively stable temperature conditions, but the varying humidity levels could have a detrimental impact on the quality of the indoor atmosphere and potentially decrease the effectiveness of the workforce. By contrast, the north façade office exhibited lower and more fluctuating temperatures, ranging from 19.8 °C to 23.6 °C, with an average of 21.74 °C. Additionally, it had higher and more stable humidity levels, ranging between 19.5% and 41.7%, with an average of 29.83%. A thermographic analysis was performed on the north façade of the Câmpulung Town Hall, utilizing thermal imaging technology to detect areas of heat loss, and thus identifying the energy inefficiency problems of the building’s exterior. The investigation found notable variations in temperature, especially around the windows, where temperatures could be as high as 14.1 °C, highlighting the insufficiency of the building’s antiquated timber-framed windows in preventing energy loss.

20 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LPLelia Letitia Popescu
Lelia Letitia Popescu
RPRǎzvan Ştefan Popescu
Rǎzvan Ştefan Popescu
Tiberiu CATALINATiberiu CATALINA
Tiberiu CATALINA
Nowadays, the enhancement of the existing building stock energy performance is a priority. To promote building energy renovation, the European Committee asks Member States to define retrofit strategies, finding cost-effective solutions. This research aims to investigate the relationship between the initial characteristics of an existing residential buildings and different types of retrofit solutions in terms of final/primary energy consumption and CO2 emissions. A multi-objective optimization has been carried out using experimental data in DesignBuilder dynamic simulation tool.