The purpose of the present study was to determine the risk factors for developing thyroid disorders based on a dose–volume histograms (DVHs) analysis. Data from a total of 116 consecutive patients undergoing 3D conformal radiation therapy for head and neck cancers was retrospectively evaluated. Radiation therapy was performed between April 2007 and December 2010. There were 108 males and 8 females included in the study. The median follow-up term was 24 months (range, 1–62 months). The thyroid function was evaluated by measuring thyroid-stimulating hormone (TSH) and free thyroxine (FT4) levels. The mean thyroid dose, and the volume of thyroid gland spared from doses ≥10, 20, 30 and 40 Gy (VS10, VS20, VS30 and VS40) were calculated for all patients. The thyroid dose and volume were calculated by the radiotherapy planning system (RTPS). The cumulative incidences of hypothyroidism were 21.1% and 36.4% at one year and two years, respectively, after the end of radiation therapy. In the DVH analyses, the patients who received a mean thyroid dose <30 Gy had a significantly lower incidence of hypothyroidism. The univariate analyses showed that the VS10, VS20, VS30 and VS40 were associated with the risk of hypothyroidism. Hypothyroidism was a relatively common type of late radiation-induced toxicity. A mean thyroid dose of 30 Gy may be a useful threshold for predicting the development of hypothyroidism after radiation therapy for head and neck cancers.
Background/Aim: To evaluate the incidence and grade of radiation pneumonitis after volumetric modulated arc therapy (VMAT) performed for the treatment of non-small cell cancer (NSCLC). Patients and Methods: Fifty consecutive non-surgical candidates with NSCLC underwent VMAT. Thirty-five patients had stage-III tumors and 15 had recurrent tumors. The prescribed radiation dose for the gross tumor and the elective nodal area was 69 Gy in 30 fractions and 51 Gy in 30 fractions, respectively. Results: Radiation pneumonitis developed in 38 patients (76%, 38/50), and grade ≥2 radiation pneumonitis developed in 11 patients (22%, 11/50). The percentage of lung volume that received a dose in excess of 5 Gy (V5), V10, V20, V30, and the mean lung dose (MLD) in the bilateral and ipsilateral lung were significantly associated with the development of grade ≥2 radiation pneumonitis. Conclusion: The incidence and degree of radiation pneumonitis are acceptable following treatment of NSCLC with VMAT.
12 January 2023 in Journal of Applied Clinical Medical Physics
Background: Radixact Synchrony®, a real‐time motion tracking and compensating modality, is used for helical tomotherapy. Control parameters are used for the accurate application of irradiation. Radixact Synchrony® uses the potential difference, which is an index of the accuracy of the prediction model of target motion and is represented by a statistical prediction of the 3D distance error. Although there are several reports on Radixact Synchrony®, few have reported the appropriate settings of the potential difference threshold.Purpose: This study aims to determine the optimal threshold of the potential difference of Radixact Synchrony® during respiratory tumor‐motion‐tracking irradiation.Methods: The relationship among the dosimetric accuracy, motion tracking accuracy, and control parameter was evaluated using a moving platform, a phantom with a basic respiratory model (the fourth power of a sinusoidal wave), and several irregular respiratory model waveforms. The dosimetric accuracy was evaluated by gamma analysis (3%, 1 mm, 10% dose threshold). The tracking accuracy was measured by the distance error of the difference between the tracked and driven positions of the phantom. The largest potential difference for 95% of treatment time was evaluated, and its correlation with the gamma‐pass ratio and distance error was investigated. The optimal threshold of the potential difference was determined by receiver operating characteristic (ROC) analysis.Results: A linear correlation was identified between the potential difference and the gamma‐pass ratio (R = –0.704). A linear correlation was also identified between the potential difference and distance error (R = 0.827). However, as the potential difference increased, it tended to underestimate the distance error. The ROC analysis revealed that the appropriate cutoff value of the potential difference was 3.05 mm.Conclusion: The irradiation accuracy with motion tracking by Radixact Synchrony® could be predicted from the potential difference, and the threshold of the potential difference should be set to ∼3 mm.
Background/Aim: We evaluated the incidence of radiation-induced hypothyroidism and its risk factors in patients with head and neck cancer who underwent radiotherapy using simultaneous integrated boost–volumetric-modulated arc therapy (SIB–VMAT). Patients and Methods: This retrospective study included 86 patients who received definitive radiotherapy using SIB–VMAT for head and neck cancer. The incidence of ≥ grade 2 hypothyroidism was evaluated. We also evaluated the relationships between hypothyroidism development and clinical factors and thyroid dose–volume parameters. Results: During a median follow-up period of 17 months (range=3-65 months), 31 patients (36.0%, 31/86) developed grade 2 hypothyroidism requiring hormone replacement therapy. No patients experienced ≥ grade 3 hypothyroidism. The cumulative incidences of hypothyroidism at 1 and 2 years after radiation therapy were 24.5% and 38.7%, respectively, with a median onset time of 10.0 months (range=3.0-35.0 months). Thyroid volume (p=0.003), volume of the thyroid spared at 60 Gy (VS60; cut-off value, 5.16 ml; p=0.009), VS70 (cut-off value, 8.0 ml; p=0.007), VS60 equivalent dose in 2 Gy fraction (EQD2; cut-off value, 7.78 ml; p=0.001), and VS70EQD2 (cut-off value, 10.59 ml; p=0.008) were significantly associated with the development of radiation-induced hypothyroidism. Conclusion: Radiation-induced hypothyroidism is not rare in patients with head and neck cancer undergoing radiotherapy using SIB–VMAT. Radiation dose–volume parameters detected in this study may be useful indicators to prevent this complication.
This study aimed to assess the clinical outcomes and predictive factors of neoadjuvant modified short-course radiotherapy (mSC-RT) for locally advanced rectal cancer (LARC). Data from 97 patients undergoing mSC-RT followed by radical surgery for LARC were retrospectively analyzed. A 2.5 Gy dose twice daily up to a total dose of 25 Gy in 10 fractions was administered through mSC-RT, and this was delivered with oral chemotherapy in 95 (97.9%) patients. Radical surgery was performed 6 (range, 3–13) weeks after mSC-RT. The median follow-up among surviving patients was 43 (8–86) months. All patients completed neoadjuvant radiotherapy with no acute toxicity grade ≥ 3. Three- and five-year local control rates were 96.3% and 96.3%, respectively. Three- and five-year overall survival (OS) rates were 92.7% and 79.8%, respectively. Univariate analyses revealed that poor OS was associated with no concurrent administration of capecitabine, C-reactive-protein-to-albumin ratio ≥ 0.053, carcinoembryonic antigen ≥ 3.4 ng/mL, and neutrophil-to-lymphocyte ratio (NLR) ≥ 1.83 (P = 0.045, 0.001, 0.041, and 0.001, respectively). Multivariate analyses indicated that NLR ≥ 1.83 was independently associated with poor OS (p = 0.018). mSC-RT followed by delayed surgery for LARC was deemed feasible and resulted in good clinical outcomes, whereas poor OS was associated with high NLR.