We demonstrate here an ultrafast, miniature, and high-performance fiber-tip Fabry–Perot (F-P) humidity sensor with -thick graphene oxide (GO) diaphragm suspended onto the end face of a capillary tube with an inner diameter of 50 μm and a cavity length of . The sensitivity to relative humidity (RH) spanning from to was examined based on the wavelength shift in the interference spectrum. Due to the intrinsic hydrophilicity of the porous GO membrane, the developed sensor exhibited an average wavelength variation of , which indicated a relatively broad and readily detectable RH linear measurement range. More prominently, an ultrahigh response time of 60 ms was achieved over other alternative F-P humidity sensors previously reported, to our knowledge.
A miniature Fabry-Perot interferometric sensor with an ultra-high temperature sensitivity was constructed by using an approximate 8-layer graphene diaphragm. The extremely thin diaphragm was transferred onto the endface of a ferrule with an inner diameter of 125 μm, and van der Waals interactions between the graphene diaphragm and its substrate created a low finesse Fabry-Perot interferometer with a cavity length of 42.86 μm. Temperature testing demonstrated a temperature-induced cavity length change of 352 nm/°C with a good linearity in the range of 20-60 °C. The result conformed well to the proposed analytical models relating to thermal expansion of trapped gas, thermal-optical property of graphene diaphragm and deflection behavior of bulged graphene blister. However, the ultra-thin diaphragm exhibited a small deflection deformation characteristic due to the applied higher loads.
Herein we demonstrate a miniature flexible optical fiber Fabry-Perot (F-P) underwater ultrasonic sensor with chitosan diaphragm coated onto the tip of a capillary with an inner diameter of $50~\mu $ m. Due to its low Young’s modulus and high surface finish, the chitosan film with a thickness of ~955 nm, formed by low-speed spin-coating of a 3% solution of biotech chitosan dissolved in 2% acetic acid, enables a high sensitivity to low-frequency ultrasonic sound pressure for the developed sensor. Because of the molecular permeability of chitosan, this type of sensor contributes to effectively reducing the working point shift of the F-P sensor caused by static pressure in underwater ultrasonic measurement. Then the ultrasonic test in a water tank offered a high sound pressure sensitivity of 52.6 mV/kPa in the tested ultrasonic range of 100 kHz to 800 kHz with a noise-limited minimum detectable pressure level of ~2.37 mPa/Hz 1/2 . Also, the directivity measurement showed the maximum signal deviation of 2.47 dB in response to ultrasound pressure in the angle range of −90° – 90°. The proposed technique greatly simplifies the miniaturized integration of all-optical ultrasonic detectors, thus suggesting the great potential in ultra-high sensitivity hydrophone in biomedical photoacoustic measurement.