Three patients with iridodialysis were recruited. A 6-0 polypropylene suture was cut to the proper length and flanged by cautery. A long (19.0 mm), ultrathin 30-gauge needle was inserted in the anterior chamber from the sclera around the iris and penetrated in the dialyzed iris, then exited through the cornea on the contralateral side. The flanged polypropylene suture was inserted in the needle from the unflanged side. After the 30-gauge needle was withdrawn, the flanged suture remained, passing the dialyzed iris and sclera. The unflanged ends of the polypropylene sutures were cut and flanged until each flange reached the sclera. It was easy to place multiple sutures. There were no cases of extrusion of the suture nor of the recurrence of iridodialysis up to 1 year. This technique is a good alternative to repair iridodialysis.
1 February 2015 in Journal of Cataract & Refractive Surgery
We report a new intrascleral fixation technique for a standard 3-piece posterior intraocular lens (IOL) using catheter needles and 30-gauge ultrathin needles instead of a special forceps and minimal intraocular manipulation in eyes without capsule support. Modified catheter needles are used to deliver the IOL haptic. The IOL haptic is secured extraocularly between the cannula and needle of a catheter needle and then advanced through the sclerotomy site. Scleral tunnels are created using 30-gauge ultrathin needles, which also serve as a guide to introduce the haptics. This technique can be performed even in cases in which miosis and corneal edema prevent anterior chamber observation. The guide needle facilitates haptic insertion into the long and narrow scleral tunnels. The procedure is a good alternative to current techniques. Dr. Akimoto is a consultant to Kowa Co., Ltd. No other author has a financial or proprietary interest in any material or method mentioned.
Purpose: To describe a patient with intrachoroidal cavitation in the normal eye that caused self-limiting recurrent macular detachment and retinoschisis. Case Report: An 80-year-old female patient with intrachoroidal cavitation in the normal eye presented with macular detachment and retinoschisis after cataract surgery. These were treated with intravitreal bevacizumab and then absorbed within 9 months. One year after cataract surgery, the patient presented with macular detachment and retinoschisis in the same eye again. These were absorbed within 4 months without treatment. Conclusion: This case suggests that similar cases of cystoid macular edema after cataract surgery can occur, and that intrachoroidal cavitation is observed not only in eyes with pathologic myopia but also in normal eyes with peripapillary atrophy; intrachoroidal cavitation can cause macular detachment and retinoschisis.
1 February 2014 in Journal of Cataract & Refractive Surgery
A new method for delivering intraocular lens (IOL) haptics through sclerotomies for intrascleral fixation using catheter needles was evaluated in pig eyes. A bent catheter needle was used to penetrate the surgical corneal wound from the presumed sclerotomy. Extraocularly, the leading haptic of the IOL was fixated between the external tube and the internal needle of the catheter needle. The fixation was strong enough to support the IOL and to extract the leading haptic through the sclerotomy site. The trailing haptic was fixated using another catheter needle extraocularly and was subsequently delivered through another sclerotomy site. Guiding with a needle was the only intraocular manipulation when delivering the trailing haptic and catheter needle through the sclerotomy. This new method is easy and safe and does not require special devices compared with other methods. Clinical evaluation in human eyes should be performed. Financial Disclosure Dr. Akimoto is a consultant to Kowa Co. Ltd. A patent application on the modified catheter needle is planned. No other author has a financial or proprietary interest in any material or method mentioned.
The purpose of this study was to evaluate the intraocular gas dynamics after 23-gauge transconjunctival sutureless vitrectomy (TSV) as compared with 20-gauge pars plana vitrectomy (PPV). A consecutive series of 290 eyes that experienced 20-gauge or 23-gauge vitrectomy with 25% sulfur hexafluoride (SF6) gas tamponade were retrospectively reviewed. Intraocular gas bubble size on postoperative Day 1 and Gas50, the interval to dissipate to a 50% gas fill, were evaluated. The mean intraocular bubble size on postoperative Day 1 was 92.0 ± 8.3% in the 20-gauge PPV cases and 83.8 ± 13.7% in the 23-gauge TSV cases (P < 0.001). The mean Gas50 was 8.6 ± 1.6 days in the 20-gauge PPV cases and 6.6 ± 2.2 days in the 23-gauge TSV cases (P < 0.001). Thorough peripheral vitrectomy and 23-gauge TSV were significantly associated with Gas50 ≤4 days (odds ratio, 4.62 and 16.8; P = 0.036 and P = 0.007, respectively). Among thoroughly vitrectomized eyes, 13 eyes treated with 23-gauge PPV with intraoperative suture placement at the sclerotomy sites had gas longevity comparative to those with 20-gauge PPV. Eyes treated with 23-gauge TSV tend to have earlier gas disappearance or incomplete gas fill. Intraoperative suture placement would be a solution.
Purpose: To develop a new technique for the placement of a Baerveldt glaucoma implant tube through a long scleral tunnel.Materials and methods: Patients with refractory glaucoma undergoing the maximum tolerated medical therapy were recruited. We created a scleral tunnel with a 24-gauge catheter needle and used the external tube for guidance when introducing a Baerveldt glaucoma implant tube. Main outcome measures included intraocular pressure, supplemental medical therapy score, intraoperative complications, and postoperative complications.Results: Nine eyes of six patients were included in the study. The mean preoperative intraocular pressure (score) was 41.0 mmHg (4.78). Mean postoperative intraocular pressures were 18.3 mmHg (0.22), 18.8 mmHg (0.13), and 16.9 mmHg (0.50) at postoperative 1, 3, and 6 months, respectively. Minor vitreous hemorrhages were observed in three cases. Postoperative hypotony (<5 mmHg) was observed only in the first case at postoperative day 3. In one case, a stent suture could not be placed because the patient was restive intraoperatively, which resulted in an expulsive hemorrhage at 3 months postoperatively. The tube could have penetrated into the anterior chamber in another case. Tube exposure and corneal erosions were not observed in all cases.Conclusion: We developed a new technique to place a Baerveldt glaucoma implant tube through a long scleral tunnel. The outcomes were comparable to other reports of Baerveldt glaucoma implant surgery, although the number of cases was limited in this study. A long scleral tunnel can substitute for a preserved scleral patch and self-scleral flap to avoid tube-related complications.