Muyang Liu

Dr. Muyang Liu

School of Electrical Engineering, Xinjiang University, Urumqi 830046, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MLMuyang Liu
Muyang Liu
JCJunru Chen
Junru Chen
Federico MilanoFederico Milano
Federico Milano
This paper proposes an on-line estimation method able to track the inertia of synchronous machines as well as the equivalent, possibly time-varying inertia from the converter- interfaced generators. For power electronics devices, the droop gain of the Fast Frequency Response (FFR) is also determined as a byproduct of the inertia estimation. The proposed method is shown to be robust against noise and to track accurately the inertia of synchronous generators, virtual synchronous genera- tors with constant and adaptive inertia, and wind power plants with inclusion of energy storage-based frequency control.

3 March 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
JCJunru Chen
Junru Chen
MLMuyang Liu
Muyang Liu
Federico MilanoFederico Milano
Federico Milano
The Virtual Power Plant (VPP) has been proposed to aggregate Distributed Generations (DGs) to act like a single power plant, thus, also has functions on the frequency and voltage support. The previous models of the VPP are static and focus on the energy trading and management. For the system transient response analysis, a dynamic VPP model must be needed. The paper proposes a reduced-order yet accurate aggregated model to represent VPP transients for the stability analysis of power systems. The goal is to provide a model that is adequate for system studies and can serve to the Transmission System Operator (TSO) to evaluate the impact of VPPs on the overall grid. The proposed model can accommodate the transient response of the most relevant controllers included in the distributed generators that compose the VPP. Using a comparison with a real-time detailed Electro-Magnetic Transients (EMT) models of the VPP confirms the validity of the proposed aggregated model. The case studies based on the IEEE 39-bus system verifies the accuracy of the proposed aggregated model on the system stability analysis.

15 August 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MLMuyang Liu
Muyang Liu
Ioannis DassiosIoannis Dassios
Ioannis Dassios
Georgios TzounasGeorgios Tzounas
Georgios Tzounas
Federico MilanoFederico Milano
Federico Milano
The paper studies the impact of realistic Wide-Area Measurement System (WAMS) time-varying delays on the dynamic behaviour of power systems. A detailed model of WAMS delays including pseudo-periodic, stochastic and constant components is presented. Then, the paper discusses numerical methods to evaluate the small-signal stability as well as the time-domain simulation of power systems with inclusion of such delays. The small-signal stability analysis is shown to be able to capture the dominant modes through the combination of a characteristic matrix approximation and a Newton correction technique. A case study based on the IEEE 14-bus system compares the accuracy of the small-signal stability analysis with Monte-Carlo time-domain simulations. Finally, the numerical efficiency of the proposed is tested through a real-world dynamic model of the island Irish system.

20 July 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JCJunru Chen
Junru Chen
MLMuyang Liu
Muyang Liu
Terence O'DonnellTerence O'Donnell
Terence O'Donnell
Federico MilanoFederico Milano
Federico Milano
The synchronization instability in the presence of a fault is a main issue for the dynamic behavior and control of grid-feeding converters. In the literature, the synchronization stability assessment is carried out considering the dynamics of Phase-Locked Loops (PLL) but the transients of converter currents are neglected. The letter shows that such a simplification leads to inaccuracies and, thus, the current transients cannot be neglected. The letter proposes a model that captures the effect of such current transients on the converter synchronization. This model allows assessing the transient behavior and, hence, the stability, of power electronics converters with high accuracy, comparable, in fact, to EMT models. The fidelity of the proposed model is duly discussed in the case study.

26 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
XDXiaoyu Deng
Xiaoyu Deng
RMRUO MO
RUO MO
PWPengliang Wang
Pengliang Wang
JCJunru Chen
Junru Chen
DNDongliang Nan
Dongliang Nan
MLMuyang Liu
Muyang Liu
As the traditional generation is gradually replaced by inverter-based resources, a lack of rotational inertia is now a common issue of modern power systems, which leads to an increasingly larger rate of change of frequency (RoCoF) following contingencies and may result in frequency collapse. As a crucial index of the frequency security and stability of power systems, the accurate estimation of the RoCoF can be a foundation for the development of advanced operations and control techniques of the future power system. This paper firstly analyzes the role of the RoCoF in typical blackouts occurring in recent years and discusses the physical and numerical nature of the RoCoF; then, by introducing the frequency spatial distribution of the power system, the paper discusses the concept of the “center” RoCoF that can present the frequency security and stability of the entire system. The estimation and prediction techniques of the maximal power system RoCoF following a contingency and the existing real-time tracking techniques of the power system RoCoF are comprehensively reviewed. Finally, the open questions and related research topics of the RoCoF estimation are discussed.

25 January 2022 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JCJunru Chen
Junru Chen
MLMuyang Liu
Muyang Liu
HGHua Geng
Hua Geng
Terence O'DonnellTerence O'Donnell
Terence O'Donnell
Federico MilanoFederico Milano
Federico Milano
It is well known that grid-feeding converters that synchronize to the grid through a Phase-Locked Loop (PLL) can become unstable after a fault. An often-neglected element that plays an important role in the converter synchronization stability is the PLL frequency limiter. While it slows down the phase change during the fault, the frequency limiter also constrains the error of the PLL input, thus leading to a longer settling time. This letter investigates the mechanism of the converter synchronization stability caused by the frequency limiter and provides a taxonomy to evaluate its impact on the overall system dynamic response.