Mieczysław Porowski

Prof. Mieczysław Porowski

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
MPMieczysław Porowski
Mieczysław Porowski

1 February 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
MPMieczysław Porowski
Mieczysław Porowski


17 November 2006 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
MPMieczysław Porowski
Mieczysław Porowski
ESEdward Szczechowiak
Edward Szczechowiak

3 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
MPMieczysław Porowski
Mieczysław Porowski
MJMonika Jakubiak
Monika Jakubiak
This article presents approximating relations defining energy-optimal structures of the HVAC (Heating, Ventilation, Air Conditioning) system for cleanrooms as a function of key constant parameters and energy-optimal control algorithms for various options of heat recovery and external climates. The annual unit primary energy demand of the HVAC system for thermodynamic air treatment was adopted as the objective function. Research was performed for wide representative variability ranges of key constant parameters: cleanliness class—Cs (ISO5÷ISO8), unit cooling loads—q˙j (100 ÷ 500) W/m2 and percentage of outdoor air—αo (5 ÷ 100)%. HVAC systems are described with vectors x¯ with coordinates defined by constant parameters and decision variables, and the results are presented in the form of approximating functions illustrating zones of energy-optimal structures of the HVAC system x¯* = f (Cs, q˙j, αo). In the optimization procedure, the type of heat recovery as an element of optimal structures of the HVAC system and algorithms of energy-optimal control were defined based on an objective function and simulation models. It was proven that using heat recovery is profitable only for HVAC systems without recirculation and with internal recirculation (savings of 5 ÷ 66%, depending on the type of heat recovery and the climate), while it is not profitable (or generates losses) for HVAC systems with external recirculation or external and internal recirculation at the same time.

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
KPKatarzyna Patrycja Pałaszyńska
Katarzyna Patrycja Pałaszyńska
Karol BandurskiKarol Bandurski
Karol Bandurski
MPMieczysław Porowski
Mieczysław Porowski
Thermally Activated Building Systems (TABS) are a way to use building structure as a thermal energy storage. As a result, renewable energy sources may be used more efficiently. The paper presents numerical analysis of a HVAC system with TABS energy demand and indoor thermal comfort of a representative room in a non-residential building (governmental, commercial, educational). The purpose of analysis is to investigate the influence of a user profile on system performance. The time span of the analysis is one year – a typical meteorological year. The model was prepared using a generally accepted simulation tool – TRNSYS 17. The results help to better understand the interaction of a user profile with TABS. Therefore they are important for the development of optimal control algorithms for energy efficient buildings equipped with such systems.