Mathias Heidinger

Mr. Mathias Heidinger

Graz University of Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2023 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
EKEveline Kuhnert
Eveline Kuhnert
KMKurt Mayer
Kurt Mayer
MHMathias Heidinger
Mathias Heidinger
CRChristine Rienessel
Christine Rienessel
Viktor HackerViktor Hacker
Viktor Hacker
MBMerit Bodner
Merit Bodner

17 March 2023 in Membranes
Verified
Journal Article
Open access
PDF file
EKEveline Kuhnert
Eveline Kuhnert
MHMathias Heidinger
Mathias Heidinger
DSDaniel-Eduardt Sandu
Daniel-Eduardt Sandu
Viktor HackerViktor Hacker
Viktor Hacker
MBMerit Bodner
Merit Bodner
Polymer electrolyte membrane water electrolysis (PEMWE) is a leading candidate for the development of a sustainable hydrogen infrastructure. The heart of a PEMWE cell is represented by the membrane electrode assembly (MEA), which consists of a polymer electrolyte membrane (PEM) with catalyst layers (CLs), flow fields, and bipolar plates (BPPs). The weakest component of the system is the PEM, as it is prone to chemical and mechanical degradation. Membrane chemical degradation is associated with the formation of hydrogen peroxide due to the crossover of product gases (H2 and O2). In this paper, membrane failure due to H2 crossover was addressed in a membrane-focused accelerated stress test (AST). Asymmetric H2O and gas supply were applied to a test cell in OCV mode at two temperatures (60 °C and 80 °C). Electrochemical characterization at the beginning and at the end of testing revealed a 1.6-fold higher increase in the high-frequency resistance (HFR) at 80 °C. The hydrogen crossover was measured with a micro-GC, and the fluoride emission rate (FER) was monitored during the ASTs. A direct correlation between the FER and H2 crossover was identified, and accelerated membrane degradation at higher temperatures was detected.

16 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
MHMathias Heidinger
Mathias Heidinger
EKEveline Kuhnert
Eveline Kuhnert
KMKurt Mayer
Kurt Mayer
DSDaniel-Eduardt Sandu
Daniel-Eduardt Sandu
Viktor HackerViktor Hacker
Viktor Hacker
MBMerit Bodner
Merit Bodner
A new method for measuring membrane degradation in polymer electrolyte fuel cells (PEFCs) is proposed. The method is based on the detection of fluoride ions in effluent water from the cathode- and anode outlet of the PEFC using photometry (PM). The fluoride emission rate (FER) is an indicator of the membrane’s state of health (SoH) and can be used to measure the chemical membrane degradation. Commercial catalyst-coated membranes (CCMs) have been tested at 80 °C and 90 °C at 30% relative humidity (RH) to investigate the reliability of the developed method for fuel cell effluent samples. To verify the measurement, a mean-difference plot was created by measuring the same data with a fluorine selective electrode. The average difference was at ±0.13 nmol h−1 cm−2, which indicates good agreement between the two methods. These new findings imply that PM is a promising method for quick and simple assessment of membrane degradation in PEM technology.

26 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
MBMerit Bodner
Merit Bodner
Željko PengaŽeljko Penga
Željko Penga
WLWalter Ladreiter
Walter Ladreiter
MHMathias Heidinger
Mathias Heidinger
Viktor HackerViktor Hacker
Viktor Hacker
Fuel starvation is a major cause of anode corrosion in low temperature polymer electrolyte fuel cells. The fuel cell start-up is a critical step, as hydrogen may not yet be evenly distributed in the active area, leading to local starvation. The present work investigates the hydrogen distribution and risk for starvation during start-up and after nitrogen purge by extending an existing computational fluid dynamic model to capture transient behavior. The results of the numerical model are compared with detailed experimental analysis on a 25 cm2 triple serpentine flow field with good agreement in all aspects and a required time step size of 1 s. This is two to three orders of magnitude larger than the time steps used by other works, resulting in reasonably quick calculation times (e.g., 3 min calculation time for 1 s of experimental testing time using a 2 million element mesh).

1 November 2025 in Journal of Power Sources
Verified
Journal Article
Open access
SRSebastian Rohde
Sebastian Rohde
ACAidan Cowley
Aidan Cowley
RHRichard Hasso
Richard Hasso
MKMario Kircher
Mario Kircher
MHMathias Heidinger
Mathias Heidinger
BGBernhard Gollas
Bernhard Gollas

22 December 2023 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
MHMathias Heidinger
Mathias Heidinger
DSDaniel Sandu
Daniel Sandu
Viktor HackerViktor Hacker
Viktor Hacker
MBMerit Bodner
Merit Bodner
Fuel cells convert chemical energy directly into electrical energy with high efficiency and without pollutants. The decomposition products in the clean exhaust gas caused by the chemical degradation of the membrane of polymer electrolyte fuel cells (PEFCs) can be used to monitor the service life of the cell. For perfluorinated sulfonic acid (PFSA)-based membranes, chemical degradation is investigated via ex situ monitoring of the effluent water. The decomposition of the PFSA backbone, which is part of the polymer electrolyte membrane (PEM), can be detected by the degradation products such as fluoride or fluorinated compounds [1]. There are multiple methods for measuring fluoride in water. We have developed a new method for the simple and precise measurement of fluoride based on the optical change caused by the quenching of a zirconium complex. This method requires only 900 µL of the sample and 100 µL of the complex [2]. We have extended the two fluoride measurement methods, namely fluoride sensitive electrode (FSE) and photometry (PM), to include ion chromatography (IC). This serves as an additional point of comparison with high accuracy and expands the measuring scope to include other ions like sulfate and their potential influence on photometric measurements. The electrochemical characterization of the materials has been improved by adapted electrochemical impedance spectroscopy (EIS) equivalent circuits, which include a more detailed analysis of the contribution of degradation processes. Linear sweep voltammetry (LSV) was used to measure the gas crossover through the membrane. Cyclic voltammetry provides information about the change in electrochemical surface area. Electrochemical characterizations and fluoride measurements are supplemented by ex situ imaging methods to determine membrane thinning. [1] M. A. Yandrasits, A. Komlev, K. Kalstabakken, M. J. Kurkowski, and M. J. Lindell, “Liquid Chromatography/Mass Spectrometry Analysis of Effluent Water from PFSA Membrane Fuel Cells Operated at OCV,” J. Electrochem. Soc., vol. 168, no. 2, p. 024517, Feb. 2021, doi: 10.1149/1945-7111/abe56a. [2] M. Heidinger, E. Kuhnert, K. Mayer, D. Sandu, V. Hacker, and M. Bodner, “Photometric Method to Determine Membrane Degradation in Polymer Electrolyte Fuel Cells,” Energies 2023, Vol. 16, Page 1957, vol. 16, no. 4, p. 1957, Feb. 2023, doi: 10.3390/EN16041957.