Pyrrolizidine alkaloids (PAs) are produced by plants as secondary compounds that are the most widely distributed natural toxins. There have been many cases of human toxicity caused by consumption of toxic plant species, as herbal teas and grain or grain products contaminated with PA-containing seeds have been reported. Companies that produce dried spices and tea leaves should examine the PA level in their products. For the first time in the literature, a simple and inexpensive electrochemical assay based on a single-use sensor was introduced for quantitative determination of senecionine (SEN) in the most frequently contaminated food sources. SEN was immobilized on a pencil graphite electrode surface by the passive adsorption technique. Differential pulse voltammetry (DPV) was used to evaluate the oxidation signal of SEN, which was observed to be around +0.95 V. The oxidation signal was specific to the SEN in the sample, and the current value was proportional to its concentration. The selectivity of our assay was also tested in the presence of other similar PAs such as intermedine, lycopsamine, and heliotrine. The detection limit is calculated by developed assay and found to be 5.45 µg/mL, which is an acceptable concentration value of SEN occurring at toxic levels for consumers. As an application of the developed sensor in food products, the electrochemical detection of SEN was successfully performed in flour and herbal tea products.
After the COVID-19 pandemic started all over the world, great importance was placed on the development of sensitive and selective bioanalytical assays for the rapid detection of the highly pathogenic SARS-CoV-2 virus causing COVID-19 disease. In this present work, an impedimetric immunosensor was developed and applied for rapid, reliable, sensitive and selective detection of the SARS-CoV-2 S1 protein. To detect the SARS-CoV-2 virus, targeting of the spike S1 protein was achieved herein by using S1 protein-specific capture antibody (Cab-S1) immobilized screen-printed electrode (SPE) in combination with the electrochemical impedance spectroscopy (EIS) technique. With the impedimetric immunosensor, the detection limit for S1 protein in buffer medium was found to be 0.23 ng/mL (equal to 23.92 amol in 8 µL sample) in the linear concentration range of S1 protein from 0.5 to 10 ng/mL. In the artificial saliva medium, it was found to be 0.09 ng/mL (equals to 9.36 amol in 8 µL sample) in the linear concentration range of S1 protein between 0.1 and 1 ng/mL. The selectivity of the impedimetric immunosensor toward S1 protein was tested against influenza hemagglutinin antigen (HA) in the buffer medium as well as in artificial saliva.