As lactoferrin (LF) plays an essential role in physiological processes, the detection of LF has attracted increasing attention in the field of disease diagnosis. However, most current methods require expensive equipment, laborious pretreatment, and long processing time. In this work, carboxyl-rich carbon dots (COOH-CDs) were facilely prepared through a one-step, low-cost hydrothermal process with tartaric acid as the precursor. The COOH-CDs had abundant carboxyl on the surface and showed strong blue emission. Moreover, COOH-CDs were used as a fluorescent sensor toward Fe3+ and showed high selectivity for Fe3+ with the limit of detection (LoD) of 3.18 nM. Density functional theory (DFT) calculations were performed to reveal the mechanism of excellent performance for Fe3+ detection. Meanwhile, COOH-CDs showed no obvious effect on lactobacillus plantarum growth, which means that COOH-CDs have good biocompatibility. Due to the nontoxicity and excellent detection performance for Fe3+, COOH-CDs were employed as a fluorescent sensor toward LF and showed satisfying performance with an LoD of 0.776 µg/mL, which was better than those of the other methods.
Elastomers with supreme mechanical adaptability where the increasing stress under continuous deformation is significantly inhibited within a large deformation zone, are highly desired in many areas, such as artificial muscles, flexible and wearable electronics, and soft artificial-intelligence robots. Such system comprises the advantages of recoverable elasticity and internal compensation to external mechanical work. To obtain elastomer with supreme mechanical adaptability, a novel liquid crystal-based organosilicon elastomer (LCMQ) is developed in this work, which takes the advantages of reversible strain-induced phase transition of liquid crystal units in polymer matrix and the recoverable nano-sized fillers. The former is responsible for the inhibition of stress increasing during deformation, where the external work is mostly compensated by internal phase transition, and the latter provides tunable and sufficient high tensile strength. Such LCMQs were synthesized with 4-methoxyphenyl 4-(but-3-en-1-yloxy)benzoate (MBB) grafted thiol silicone oil (crosslinker-g-MBB) as crosslinking agent, vinyl terminated polydimethylsiloxane as base adhesive, and fumed silica as reinforcing filler by two-step thiol-ene “click” reaction. The obtained tensile strength and the elongation at break are better than previously reported values. Moreover, the resulting liquid crystal elastomers exhibit different mechanical behavior from conventional silicone rubbers. When the liquid crystal content increases from 1% (w/w) to 4% (w/w), the stress plateau for mechanical adaptability becomes clearer. Moreover, the liquid crystal elastomer has no obvious deformation from 25 °C to 120 °C and is expected to be used in industrial applications. It also provides a new template for the modification of organosilicon elastomers.
Lactoferrin (LF) is an iron-binding glycoprotein with various biological activities that has been extensively used in food and medical applications. Several methods for detecting LF have been reported, but they still face challenges in terms of sensitivity and simplicity of detection. To achieve an accurate and efficient detection of LF, we developed a method for the determination of LF in lactoferrin supplements using carbon dots (CDs) fluorescent probes. The N, S-doped PPI carbon dots (N, S-PPI-CDs) were prepared using a protein (peanut protein isolate) and cysteamine as precursors. The prepared N, S-PPI-CDs exhibited intense blue fluorescence and good biocompatibility, while the fluorescence intensity of the N, S-PPI-CDs showed a good linear relationship with Fe2+/Fe3+ concentration (0–2 μM). The N, S-PPI-CDs exhibited a high potential ability to rapidly detect Fe2+/Fe3+ within 30 s, with a limit of detection (LoD) of 0.21 μM/0.17 μM. Due to the reversible binding of LF to Fe, the N, S-PPI-CDs showed a high sensitivity and selectivity for LF, with a limit of detection (LoD) of 1.92 μg/mL. In addition, LF was quantified in real sample LF supplements and showed a fluctuation in recovery of less than 2.48%, further demonstrating the effectiveness of the fluorescent N, S-PPI-CDs sensor.